E2230 Rev 09.03.2021 Specifications Measured parameters Temperature, Humidity, CO level Additional features Clock, Calendar 10 s ... 1 h measurement interval, 16000 datasets memory, Data Logging wireless data transmission and time synchronization Digital RH and T sensor, Sensors Optical NDIR CO2 sensor 0...85 %RH, 0...+50 °C,...
E2230 Rev 09.03.2021 Product description Air Quality Wireless Datalogger Panel E2230 is intended for use in schools, hospitals, offices and other areas. The device provides autonomous long-time monitoring of indoors climate with high accuracy and stability. The data logger uses the latest achievements in digital humidity and temperature sensing...
E2230 Rev 09.03.2021 Operating conditions The device should be used both in a non-hazardous area and in a basic electromagnetic environment, where the latter is defined in EN 61326-1. Avoid strong mechanical shock and vibrations. Avoid corrosive atmosphere and areas highly contaminated with dust, oil mist, etc.
Page 6
E2230 Rev 09.03.2021 Mains power adapter (included) Dimensions 67 x 44 x 44 mm, cable 1,2 m, 9 W, 9 VDC, 1 A, connector 5,5/2,1 mm...
After these procedures logger shall start indicating and logging if datalogging is permitted. (Depending if circular memory overwriting is enabled or not) E2230 series 2 seconds LEDs shall blink together after all procedures are finished to indicate indication/logging mode.
Page 9
E2230 Rev 09.03.2021 Browser support The numbers in the table specify the first browser version that fully supports the device web server. IP Address For connecting to the device user should connect to the device by using its IP address. If user is connected to the Hotspot then device IP is 192.168.4.1...
Page 10
E2230 Rev 09.03.2021 Main page After navigating to the device, the device measurement status page will open.
Page 11
E2230 Rev 09.03.2021 By clicking the left arrow icon, the user will be navigated to the Main menu. Device status - First page which indicates measured values of the device. Device status with Chart - Similar to the first page but with added support for stationary logging into the chart AP WiFi configuration - Hotspot configuration and data sending configuration...
Page 12
Note 1: Time will be saved until reboot. After reboot the configuration will revert back to unconfigured state. Note 2: E2230 can be configured using Plurasens configurator. If the device is connected to the computer via USB, configuration via Wi-Fi can not be done.
Page 13
Register 422 Last logged data SECONDS 2.3 Configuration / checking mode E2230 series can be put into configuration / checking mode by writing 1 into register 255 while the device is in indication / logging mode. After that device 2 seconds LEDs shall blink independently to indicate that the device is in configuration mode.
Page 14
E2230 Rev 09.03.2021 Register 280, Writing 42330 will clean internal memory of the device and will reboot the device Register 430, CO2 ABC period (days), default 14 Register 432, CO2 ABC baseline value (ppm), default 430 ppm Register 434, CO2 current ABC shift...
Page 17
431 / 40432 RW Days since last ABC shift CO2 ABC baseline value, 432 / 40433 RW 434 / 40435 CO2 current ABC shift Note: E2230 series shall only respond to Modbus functions in indication / logging mode once per second. Frequent requests shall not be followed.
Manufacturer or damaged by customer error or negligence or if there has been an unauthorized modification. Manufacturer contacts Evikon MCI OÜ Teaduspargi 7/9, Tartu 50411 Estonia info@evikon.eu...