Download Print this page

MAGNASPHERE HSS Series Installation Instructions

Advertisement

Quick Links

MAGNASPHERE L2X-800 INSTALLATION INSTRUCTIONS: All Models of (L2X) 800-Series [Page:1]
CAUTION: MAGNASPHERE MAGNET MODULES AND ANTI-REMOVAL MAGNETS ARE EXTREMELY POWERFUL: TAKE PRECAUTIONS TO AVOID THE MAGNETIC ATTRACTION OF
SHARP TOOLS AND TO AVOID INJURY FROM THE PINCHING FORCE BETWEEN THE MAGNET AND FERROUS METALS OR OTHER MAGNETS.
Attention: modules à aimants Magnasphere et anti-enlèvement aimants sont très puissants: prendre des précautions pour éviter l'attraction magnétique d'outils
tranchants et à éviter les blessures de la force de pincement entre l'aimant et les métaux ferreux ou d'autres aimants.
Provided by Manufacturer (per module set)
1 L2X switch module
1 L2X magnet module
7 switch & magnet module self-tapping screws (#10-32 x 2")
1 self-tapping screw (#6, 1" long)
(P/N: SP062)
2 1/16" plastic spacer plates
1 Removal-Tamper magnet
2 Removal-Tamper caps
1 1/2" NPT Plug
1/2" NPT PLUG
22 AWG (36" L)
(Longer leads can be ordered)
#10 SCREWS
1/16" SPACER
1/16" SPACER
Installation Plan
Plan to mount the switch module to the door frame, close to the door/frame gap and without door-swing
interference. The magnet module should be mounted directly below the switch. Spacers may be used to
attain sufficient alignment of the modules. Recommended placement for the set is 8 inches from the latch
side of the door, at the top. The operating gap must not exceed 3/16". Provided templates may assist
locating holes. *A gap up to 1/8" is required for compliance with UL634 Level 2 high security standard.
Mark & pilot-drill all hole locations. Drill the 3 mounting hole locations for the #10 screw (#21 bit). Drill the
Removal-Tamper screw location for the #6 screw (#35 bit). Hold the switch module in position: Drive each
screw in until seated, securing the device.
CAUTION: Magnasphere's magnet module and anti-removal magnet are extremely powerful: Take
precautions to avoid the magnetic attraction between the magnet and ferrous metals (or other
magnets). Align the magnet module directly below the switch module. Determine whether spacers are
needed to achieve mounted alignment of the modules. Hold the magnet module and any spacers in position
and drill the 4 hole locations for #10 screws (#21 bit). Drive each screw in until seated, securing the device.
Insert the Removal-Tamper magnet and then the Removal-Tamper plug into the 3/8" hole at the face of the
switch module. Check that the gap between modules is no greater than 1/8". The mechanical installation of
the set is complete.
Additional mounting hardware, resistor configurations, cable lengths, and other variants are available.
Patents #5673021, #6603378, #8228191, #8314698 & Patents Pending
Patents: #5977873, #6506987, #6803845, #7291794, #7944334, #8314698, #6087936, #6603378, #7023308, #RE39731, #8228191, #8648720 & Other Patents Pending
MAGNASPHERE N22 W22931 Nancys Ct. Ste 3, Waukesha, WI 53186
Required Tools and Components
REMOVAL
TAMPER
#10 SCREWS
CAP
#6 SCREW
REMOVAL
TAMPER
MAGNET
#10 SCREW
SWITCH MODULE
#10 SCREWS
MAGNET MODULE
SWITCH
MODULE
DOOR FRAME
UP TO
3/16"
GAP*
MAGNET
MODULE
DOOR
SWING
DOOR
Intrinsically Safe Barrier (Listed to at least the Hazardous Location Class)
Power drill
Drills bits: #35,#21
Phillips screwdriver or a Phillips bit for use in the drill/bit-driver
Rule (or any linear measuring instrument)
A center punch (& hammer) for more accurate hole locations may be used
A pilot drill bit for screws (3/32" or smaller) may be used
Additional 1/16" SPACERS (10/ BAG – MAGNASPHERE P/N SP062)
Adjustable wrench
Pipe wrench
Thread Locking Compound or a lockable N.P.T plug
Rigid 1/2" NPT Conduit (18" Min. per UL634 Level 2 Standard)
Specifications
Max Current: 0.25 A Resistive
Max Voltage: 30 VDC
Max Power: .25 W Resistive
Suitable for outdoor use.
The Magnasphere HSS Level 2 series
is intended to be connected to a UL
Listed compatible control panel for US
applications and a ULC Listed
compatible control panel for Canadian
.
applications
Resistors are Optional
SC1
Closed
WHT
ALARM
Common
BLK
SC2
Closed
ORN
ALARM
Common
PUR
Supervise
d
TAMPER
GRN
Common
CIRCUT
MT
Magnet
Tamper
YEL
PT
Pry
L2D Series
Tamper
BLU
Wrench Note
Recommended: Pre-Fasten an 1/2" NPT conduit section
to the Switch Module in order to prevent excessive stress.
tel 262.347.0711
fax 262.347.0710
Provided by Installer
(see p.2 #3, note)
Resistors are Optional
SC
SC
ALARM
TAMPER
CIRCUT
MT
PT
L2S Series
Test the Magnet-Tamper circuit
here with a powerful magnet
Remove to test the
Pry Tamper circuit
X
www.magnasphere.com
Closed
WHT
Open
RED
Common
BLK
Supervise
d
GRN
Common
Magnet
Tamper
YEL
Pry
Tamper
BLU

Advertisement

loading
Need help?

Need help?

Do you have a question about the HSS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for MAGNASPHERE HSS Series

  • Page 1 SHARP TOOLS AND TO AVOID INJURY FROM THE PINCHING FORCE BETWEEN THE MAGNET AND FERROUS METALS OR OTHER MAGNETS. Attention: modules à aimants Magnasphere et anti-enlèvement aimants sont très puissants: prendre des précautions pour éviter l'attraction magnétique d'outils tranchants et à éviter les blessures de la force de pincement entre l'aimant et les métaux ferreux ou d'autres aimants.
  • Page 2 Intrinsic Safety Requirements #6 Refer to figure 1-1 for completed installation. #7 Magnasphere L2X Series is a Simple Apparatus; when used with an Intrinsically safe Barrier, will meet or exceed the requirements for certain hazardous locations. Hazardous Zone...

This manual is also suitable for:

L2x-800