TECHNICAL DESCRIPTION
SET-1640
16 differential /32 single-ended channel fault insertion card
This document 9040TDD0250 is a technical description of the SET-1640.
Note
Before you begin, complete the Software and Hardware installation procedures
applicable to your application.
Note
The guidelines in this document are specific to the SET-1640. The other
components in the system might not meet the same safety ratings. Refer to the
documentation of each component in the system to determine the safety and
EMC ratings for the entire system.
1 of 11
www.smart-e-tech.com
Issue
02
05/04/2022
MORE INFORMATION ON OUR WEBSITE:
www.smart-e-tech.de/slsc
SET-1640 Technical Description

Advertisement

loading
Need help?

Need help?

Do you have a question about the SET-1640 and is the answer not in the manual?

Questions and answers

Summary of Contents for SET SET-1640

  • Page 1 Note The guidelines in this document are specific to the SET-1640. The other components in the system might not meet the same safety ratings. Refer to the documentation of each component in the system to determine the safety and EMC ratings for the entire system.
  • Page 2: Safety Guidelines

    Safety Guidelines Caution Do not operate the SET-1640 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it for repair.
  • Page 3 The SET-1640 device is a physical layer of Peripheral Sensor Interface (PSI5) for NI-SLSC. This card provides 16 isolated PSI5 slave inputs that designed to work according to PSI5 Technical Specification V2.2 Base Standard. The SET-1640 send slave’s data to a PSI5 master Device Under Test (DUT) and receive data from the DUT.
  • Page 4 Reference routing to the fault bus. Note At startup, Enable_0 is activated. If Enable_0 is switched, all Enable will be switched on Slot 1. All voltages are relative to GND unless otherwise noted. 4 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 5 GND_4 REF_1 Enable_1 Enable_0 REF_0- DUT_2 GND_2 DUT_3 DUT_1 GND_1 GND_3 DUT_0 GND_0 Signal Description DUT_x Device Under Test x Ground connection No connection Enable_x Enable x J1 Connector Pin Assignments 5 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 6 XJ2 Connector Pinout (Rear) 6 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 7 DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND XJ2 Connector Pin Assignments Signal Description Digital Input signal connection Ground connection No connection XJ2 Connector Signal Descriptions 7 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 8 XJ3 Connector Pinout (Rear) Signal Slot1/Slot2 Pins Instrument 0+ Instrument 0- Instrument 1+ Instrument 1- Fault_A Fault_B Fault_C Fault_D XJ3 Connector Pin Assignments 8 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 9: Led Behavior

    Absolute Maximum Ratings Property Condition Value Comment Measured between Max. Channel Voltage 30 V Ch Data & Ch GND Max. Channel Reverse Measured between 30 V Voltage Ch Data & Ch GND 9 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 10 Front Panel Connector 2x female DB -44 high- For mating connectors density D-Sub with 4-40 and cables, see below UNC screw lock RTI Connector 2mm hard metric per Any RTI marked IEC 61076-101 10 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
  • Page 11 Environmental Property Condition Value Comment Relative, non- Operating Humidity 10%-90% condensing Relative, non- Storage Humidity 5%-95% condensing Operating Forced-air cooling from 0°C-40°C Temperature chassis Storage Temperature -40°C-85°C Maximum Altitude 2000 m 11 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...