Do you have a question about the SET-1640 and is the answer not in the manual?
Questions and answers
Summary of Contents for SET SET-1640
Page 1
Note The guidelines in this document are specific to the SET-1640. The other components in the system might not meet the same safety ratings. Refer to the documentation of each component in the system to determine the safety and EMC ratings for the entire system.
Safety Guidelines Caution Do not operate the SET-1640 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it for repair.
Page 3
The SET-1640 device is a physical layer of Peripheral Sensor Interface (PSI5) for NI-SLSC. This card provides 16 isolated PSI5 slave inputs that designed to work according to PSI5 Technical Specification V2.2 Base Standard. The SET-1640 send slave’s data to a PSI5 master Device Under Test (DUT) and receive data from the DUT.
Page 4
Reference routing to the fault bus. Note At startup, Enable_0 is activated. If Enable_0 is switched, all Enable will be switched on Slot 1. All voltages are relative to GND unless otherwise noted. 4 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
Page 5
GND_4 REF_1 Enable_1 Enable_0 REF_0- DUT_2 GND_2 DUT_3 DUT_1 GND_1 GND_3 DUT_0 GND_0 Signal Description DUT_x Device Under Test x Ground connection No connection Enable_x Enable x J1 Connector Pin Assignments 5 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
Absolute Maximum Ratings Property Condition Value Comment Measured between Max. Channel Voltage 30 V Ch Data & Ch GND Max. Channel Reverse Measured between 30 V Voltage Ch Data & Ch GND 9 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
Page 10
Front Panel Connector 2x female DB -44 high- For mating connectors density D-Sub with 4-40 and cables, see below UNC screw lock RTI Connector 2mm hard metric per Any RTI marked IEC 61076-101 10 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...
Page 11
Environmental Property Condition Value Comment Relative, non- Operating Humidity 10%-90% condensing Relative, non- Storage Humidity 5%-95% condensing Operating Forced-air cooling from 0°C-40°C Temperature chassis Storage Temperature -40°C-85°C Maximum Altitude 2000 m 11 of 11 www.smart-e-tech.com SET-1640 Technical Description Issue 05/04/2022...