  • Page 1 ATO One 2 SE quick start guide A0 2021-11-23 Kamoer Fluid Tech (Shanghai) Co., Ltd. www.kamoer.com...
  • Page 2: Panel Introduction

    ATO One 2 SE has rich status indication, when the refill water overflows or overtime, when the water in the refill container is insufficient, ATO One 2 SE will have indicator light and buzzer alarm.
  • Page 3: Installation

    Installation Step 1: The optical sensor (S1) is installed on the normal water level line and used as the water refill sensor. Note that the optical level sensor should be far away from the place with bubbles, otherwise it will be interfered and misjudged; Step 2: The optical sensor (S3) is installed above the normal water level to be used as anti-overflow sensor.
  • Page 4 than the position of the liquid level of the freshwater reservoir at any time. The water outlet of pipe must be higher than the liquid level of tank/sump; Step 4: Plug the refill pump power plug into the pump connector. The anti-dry burn identification sensor of the refill pump should be kept upward, so that when the water of the freshwater reservoir is insufficient, it can be timely found and...
  • Page 5 Alarm and Reminder State Alarm Action Fast beep, red light flashes 1. Check the refill pump connection. Pump is not synchronously 2. If the problem is not solved, replace inserted or faulty (On 0.1s, Off 0.1s) a refill pump. 1. Check if the S3 sensor is installed correctly.
  • Page 6 Note  Please use the power adapter that comes with the product and operate under the specified operating environment.  The red and blue optical sensors need to be cleaned and wiped after long-time use to prevent the accuracy of the sensor from being affected. ...
  • Page 7: Technical Parameters

    Technical parameters input: AC 100V~240V Power adapter output:DC12V 1A Sensor Optical sensor Submersible pump DC12V submersible pump Temperature:0 -40°C Working environment Humidity:80%(non-condensation) Packing list Name Specification Unit Controller ATO One 2 Plastic magnet black Submersible pump DC12V 5W Tube Holder transparent PVC pump tube 8*11mm;...
  • Page 8: Warranty & Service

    Kamoer Fluid Tech (Shanghai) Co., Ltd. Addr: Building 4, No.79 Xiangjing Road, Songjiang District, Shanghai Website: www.kamoer.com Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We reserve the right to improve or alter appearance and technical specifications without notice.