Download Print this page

Desco 19662 Accompaniment To The Installation, Operation And Maintenance Manual

Dual-wire dual operator monitor

Advertisement

Quick Links

Dual-Wire Dual Operator Monitor
Installation, Operation and Maintenance
Figure 1. Desco 19662 Dual-Wire Dual Operator Monitor
Description
The Desco
19662
Dual-Wire Dual Operator Monitor
monitors two operators and two ESD worksurfaces
eliminating the need for periodic testing and
record keeping of wrist straps. The Dual-Wire Dual
Operator Monitor uses low-voltage steady state DC
continuous-loop technology to continuously monitor
(versus pulsed or intermittent) dual-wire wrist strap
functionality. Independent audio and visual alarm
conditions identify the status of the worksurfaces and
operators. Two operator remotes with 10 foot cables are
included for use at adjacent workstations. Each monitor
is calibrated with accepted procedures and standards
traceable to the National Institute of Standards and
Technology (NIST) and includes a NIST certificate.
Dual Wire Monitor Technology
Desco dual wire dual operator monitors uses a loop
electrical resistance technology. A +5 or +8 volt test
signal1 is generated by the monitor and placed on one
conductor of the dual wire wrist strap. The test voltage
is bridged to the opposite conductor through the skin of
the wearer of the wristband and returned to the monitor.
Resistance is monitored with a stable continuous signal
through one conductor, across the skin of the operator,
and returning to the monitor through the opposite
conductor. Desco dual wire dual operator monitors
determine that the operator's path-to-ground is between
the 10 or 35 megohms2 upper limit (adjustable) and 1
megohm1 lower limit.
1. See Operator Test Voltage section below for pass/
fail specs. User should determine if these voltages
can damage the device being handled. Other
lower voltage monitoring systems may need to be
considered.
2. See Operator Test Range section below for pass/fail
specs.
TB-3083 Page 1 of 5
December 2020
TECHNICAL BULLETIN TB-3083
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website:
ANSI/ESD S20.20 section 7.3 states "Compliance
verification records shall be established and maintained
to provide evidence of conformity to the technical
requirements." Per ANSI/ESD S1.1 Annex A.3 Daily
(wrist strap system) testing may be omitted if constant
monitoring used." Per ESD Handbook ESD TR 20.20
section 5.3.2.4.4 "Typical Test programs recommend
that wrist straps that are used daily should be tested
daily. However, if the products that are being produced
are of such value that knowledge of a continuous,
reliable ground is needed, and then continuous
monitoring should be considered or even required."
The Dual-Wire Dual Operator Monitor and its
accessories are available in the following item numbers:
Item
Description
19662
Dual-Wire Dual Operator Monitor
19663
Mounting Brackets
50524
Limit Comparator
50525
Replacement Operator Remote Kit, Black
50526
Replacement Operator Remote Kit, White
19262
Replacement Power Adapter, 12 VDC
Packaging
19662
Dual-Wire Dual Operator Monitor
1 Dual-Wire Dual Operator Monitor
1 Power Adapter, 12VDC, with interchangeable plugs
(North America, UK/Asia, Europe)
2 Operator Remotes with Attached Cables
(1 Black, 1 White)
2 White Mat Monitor Cords
1 Monitor Ground Cord
1 Certificate of Calibration
19663
Mounting Brackets
2 Mounting Brackets
4 Pan Head Screws, 8-32 x 1/8"
Made in the
United States of America
Desco.com
© 2020 DESCO INDUSTRIES INC
Employee Owned

Advertisement

loading

Summary of Contents for Desco 19662

  • Page 1 2. See Operator Test Range section below for pass/fail specs. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-3083 Page 1 of 5 December 2020 ©...
  • Page 2: Features And Components

    When the LED is illuminated red and the alarm sounds, worksurface 2 is not properly grounded. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-3083 Page 2 of 5 December 2020 ©...
  • Page 3: Installation

    Figure 3. Installing the Dual-Wire Dual Operator Monitor DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-3083 Page 3 of 5 December 2020 ©...
  • Page 4: Specifications

    DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-3083 Page 4 of 5 December 2020 ©...
  • Page 5 Replacement remotes are available as Desco items 50525 and 50526 DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-3083 Page 5 of 5 December 2020 ©...