shaft being careful of the tight tolerances between the bushing and sleeve.
stamped word 'UP' should be at the top, 12 o'clock position.
11.Bolt the casing cover to the rear casing using the (4) hex socket head bolts (Item 8).
Tighten the bolts evenly to avoid binding, and torque in accordance with the torque
table on page 9. Check for free rotation of the assembly
12.Place impeller key (Item 15) into the shaft keyway with
material stamp facing up and slide the impeller (Item 2)
onto the shaft.
Tighten and torque the impeller nut and then secure the
impeller nut with the set screw (Item 11). [This completes
the rotating assembly, also called the PB assembly.]
13.Mount the rotating assembly to the frame adapter (Item 50)
using the four hex head bolts (Item 67). Evenly tighten the
bolts and torque in accordance with the torque table on
page 9.
14.Mount the outer magnet (Item 48) on the motor shaft.
Tighten the outer magnet set screw (Item 76) and torque in accordance with the
torque table on page 9. Ensure that no foreign metallic objects come in contact with
the outer magnet that could be attracted to the magnets. Remove any metal shavings
or grinding particles that have become attracted to the magnets using the adhesive
side of tape or similar material.
15.For MHL pumps be sure the (3) heat insulation sheets (Item 101) are in place between
the motor C-face flange and the frame adapter for this step. Install the motor to the
frame adapter using caution as strong magnetic forces will
pull the magnets together.
magnet to fit over the rear casing without touching the
sides of the rear casing can or the magnet segments of
the outer magnet and move the motor to the frame
adapter to engage the magnet coupling. Ensure the motor
flange pilot spigot engages the machined recess on the
frame adapter and is square to the frame adapter flange
face.
A small AND EVEN motor flange gap is normal.
Tighten the motor mounting bolts to 55 ft-lbs.
16.Working at the process end of the pump now, place the
new gasket (Item 80) into the pump casing (Item 2) and
locate the pump casing to the rotating assembly making sure the casing gasket did not
MPL/MHL IOM-R2 Copyright 2020 Magnatex Pumps, Inc.
Thread on the impeller nut (Item 6).
WARNING
BE CAREFUL TO AVOID TRAPPING
YOUR FINGERS BETWEEN THE MOTOR
C-FACE FIT AND THE FRAME ADAPTER.