Page 1
Extremely simple installation and ease of use enable this instrument to be installed immediately and effectively. Its reliable and precise nature make it suitable for use in the most demanding conditions and hence ideal for industrial applications. Logic S.r.l. Via del Tovo, 5/3 27020 Travacò Siccomario (PV) WTS3-IIS ........
Installation Manual WTS3 Series II WTS3 – GENERAL DESCRIPTION WTS3 weight conditioner and transmitter has been developed to interface strain gage transducers with industrial automation systems (such as PLC, computers etc..). The board supplies up to 4 load cell (350 ohm) amplifies the load cell signal and perform 2 different analog outputs: a 0 - 10 V and a current output 0 - 20 mA or 4 - 20 mA (Factory selected).
Installation Manual WTS3 Series II APPLICATION AND PRINCIPLE OF OPERATION The module WTS3 is an amplifier for strain gage. This amplifier offers a simple and valid procedure for calibration using rotary switches and trim-pots. The supply voltage of the transducer is 10 Vdc with the possibility of connection to 4 or 6 wires. With six-wire connection, making a correct compensation of the voltage drop on the connecting cables, for a calibration easier and a higher accuracy.
Page 4
Installation Manual WTS3 Series II SET UP : SWITCH SW3 SELECTION ELECTION OF THE CURRENT RANGE Select switch SW3-5 according to the following table to select the output current range 4 - 20 mA or 0 - 20 mA : SW3-5 Output signal range 4 - 20 mA...
Installation Manual WTS3 Series II TERMINAL BOARD CONNECTIONS OWER SUPPLY Use a power cable, with suitable protection to the environment in which they are installed, with a maximum section of 1.5 sqmm. OAD CELLS Load cell output is a low level signal (few millivolts); then it is necessary to use a good quality shielded cables.
Connect WTS3 as follows before to supply the board. TB1-4 TB5-8 TB9-12 TB13-16 +24 V Using cables and load cells LOGIC Srl refer to the following table the correspondence between the color codes Logic and signals of the load cell. SIGNAL DESCRIPTION EXTENSION CABLE LOAD CELL...
Page 7
Installation Manual WTS3 Series II TRIM-POTS AND ROTARY SWITCH FUNCTION SW1 : 16 position rotary switch for coarse span adjustment (10Vdc full scale). P1 : Trim-pot for fine adjustment of span (full scale 10 Vdc). SW2 : 16 position rotary switch for coarse zero adjustment (0Vdc). P2 : Trim-pot for fine adjustment of zero (0 Vdc).
Installation Manual WTS3 Series II CALIBRATION PROCEDURE If not otherwise specified, the device will come with the following setting range : • Input : 0 - 2 mV/V • Voltage output : 0 - 10 Vdc • Current output : 4 - 20 mA If you need a different range of calibration steps below.
Page 9
Installation Manual WTS3 Series II RANGE CALIBRATION 0-10V and 4-20mA • Connect a voltmeter to voltage output between + Vout e - Vout . • Switch on the system and wait about 15 minutes for warm-up. • Be sure the weighing system is completely empty. •...
Page 10
Installation Manual WTS3 Series II MECHANICAL DIMENSIONS WTS3 MECHANICAL DIMENSIONS WTS3-B LOGIC Srl - Via del Tovo 5/3 Travaco' Siccomario (PV) www.logic-pavia.it PG13,5 WEIGHT TRANSMITTER WTS3 SERIES Power Supply : 24 Vdc Load Cells Supply : 10 Vdc Max. Current : 0,15 A Max.
Page 11
DICHIARAZIONE DI CONFORMITA’ DECLARATION OF CONFORMITY Marcatura CE CE Mark NOME DEL FABBRICANTE : LOGIC s.r.l. Name of manufacturer : INDIRIZZO DEL FABBRICANTE : Via del Tovo 5/3 - Travacò Siccomario - PAVIA Address of manufacturer : DICHIARA CHE IL PRODOTTO...