Advertisement

Quick Links

TA-15/6P...200/6P
Instruction and Operation Manual
Caution:
There is always a risk involved in the handling of electrical machinery!
Therefore mounting and maintenance should only be done by authorized personnel.
Pikatron GmbH
division TAE Antriebstechnik
Raiffeisenstrasse 10
D-61250 Usingen
http://www.tae-antriebstechnik.de
TA_BA TA-15-200_6P_EN.PDF
The German text applies in cases of doubt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TA-15/6P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for tae TA-15/6P

  • Page 1 Instruction and Operation Manual Caution: There is always a risk involved in the handling of electrical machinery! Therefore mounting and maintenance should only be done by authorized personnel. Pikatron GmbH division TAE Antriebstechnik Raiffeisenstrasse 10 D-61250 Usingen • • •...
  • Page 2: Technical Data

    (refer to connection diagram TA-15/6P...200/6P) Ensure that your line voltage corresponds to the voltage indicated on the type marking of the unit. Terminal Strip KL. 3 (at TA-15/6P KL.3=KL.1) L1 - L2 - L3 Three phase a.c. line input and voltage according to type marking on unit.
  • Page 3 TA-15/6P ...200/6P Terminal 7 and 8 Terminals for contacts of all malfunction signals. (Contacts open in event of fault) Terminal 2, 5, 6 Speed potentiometer With this potentiometer the speed is infinite variable from minimum to maximum speed. Poti-connect: KL. 5 = Beginning KL.
  • Page 4: Drive Control Adjustments

    TA-15/6P ...200/6P Drive control adjustments Phase ballance Adjustments of the triggering angeles of the individual Thyristors in order to obtain equal currents for all Thyristors. Do not adjust. (This potentiometer is adjusted and sealed by the manufacturer) Acceleration rate Adjustment of the linear acceleration time of the motor from min. to max.
  • Page 5 TA-15/6P ...200/6P Functional tests and preliminary adjustments before operation Caution! Do not use any Mega-Ohm-meter, buzzer or similar test instruments. Test instruments must be galvanically seperated from a.c. line. Armature feedback control (UA-controlled) Jumper VI must be installed if a controlled decelaration at drive stop is requested. For Emergency off the connection between terminals 24 and 25 must be opened (Quick-stop).
  • Page 6: Troubleshooting

    TA-15/6P ...200/6P Current limit: In order to check the current limit the field must be disconnected, the motor must be blocked and the field control (jumper XI) must be jumpered. Switch on drive and preselect speed and adjust the requested current with P5 (current limit). The red LED 6 (current limit) must light up.
  • Page 7: Fault Location

    TA-15/6P ...200/6P Fault location Symptom Possible causes LED 8 (Power on) does not light up. a) Defective fuse Si 1 on the upper PC-board b) One phase is missing c) No supply voltage (115V) for relays d1 and d2. Check voltage (115V) between terminals 9 and d) LED 8 or D37 defect.
  • Page 8 Interrupted potentiometer connection from terminal 5 to start of speed-potentiometer. f) Wrong polarity +/- on d.c. tachometer connection. (Check terminal connection 11-20) This concludes the preliminary preparation and adjustment of the Thyristor-Drive-Control Type TA-15/6P...200/6P Instruction & Operating Manual missprints and technical changes reserved...
  • Page 9: Connection Diagram

    TA-15/6P ...200/6P Connection diagram Kl.3 Netz (bei TA-15/6P ist Kl.3=Kl.1) LINE (at TA-15/6P is Kl.3=Kl.1) ALIMENTATION EN ALTERNATIF Anker ARMATURE INDUIT E1/F1 E2/F2 Kl.1 Feld FIELD EXCITATION Reglerfreigabe DEBLOCAGE Schleichgang JOG SPEED VITESSE D`ACCROCHAGE Sollwertpotentiometer Störmeldung SPEED POTENTIOMETER POTENTIOMETRE DE VITESSE...
  • Page 10 TA-15/6P ...200/6P Mounting template TA-15/6P 7 x 13 TA-40/6P 7 x 13 TA-60/6P...200/6P ø10,5 Instruction & Operating Manual missprints and technical changes reserved...

This manual is also suitable for:

Ta-40/6pTa-60/6pTa-100/6pTa-200/6p

Table of Contents