Rittal TopTherm LCP Rack CW Assembly And Operating Instructions Manual

Rittal TopTherm LCP Rack CW Assembly And Operating Instructions Manual

Liquid cooling package
Table of Contents

Advertisement

Quick Links

Montage-, Installations- und Bedienungsanleitung
Assembly and operating instructions
Notice d'emploi, d'installation et de montage
Montage- en bedieningshandleiding
TopTherm LCP Rack CW
TopTherm LCP Inline CW
TopTherm LCP Inline flush CW
3311.138/238/268
3311.538/568
3311.148/548

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TopTherm LCP Rack CW and is the answer not in the manual?

Questions and answers

Summary of Contents for Rittal TopTherm LCP Rack CW

  • Page 1 TopTherm LCP Rack CW TopTherm LCP Inline CW TopTherm LCP Inline flush CW 3311.138/238/268 3311.538/568 3311.148/548 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Notice d'emploi, d'installation et de montage Montage- en bedieningshandleiding...
  • Page 2 Foreword Foreword Dear Customer! Thank you for choosing a Rittal Liquid Cooling Package (referred to hereafter also as "LCP"). This documentation applies to the following three units in the LCP series: – LCP Rack CW – LCP Inline CW – LCP Inline flush CW...
  • Page 3: Table Of Contents

    5.2.6 Fit the trim panels if siting without a rear adaptor .............. 25 Inspection and maintenance ..66 5.2.7 Installation and baying of the Liquid Cooling Package ............25 Storage and disposal ....67 5.2.8 Mounting the side panel ........26 Rittal Liquid Cooling Package...
  • Page 4 16.4.3 Hardware for startup current limitation ....85 16.5 Water circulation diagram ......85 Preparation and maintenance of the cooling medium ......86 Frequently Asked Questions (FAQ) ..........87 Glossary ........91 Customer service addresses ..92 Rittal Liquid Cooling Package...
  • Page 5: Notes On Documentation

    We reserve the right to make changes in content. Storing the documents Rittal GmbH & Co. KG will not be held liable for any The assembly and operating instructions as well as all mistakes in this documentation. Liability for indirect...
  • Page 6: Safety Instructions

    2 Safety instructions Safety instructions Caution! Risk of malfunction or damage! The Liquid Cooling Packages produced by Rittal Do not modify the unit! Use only original GmbH & Co. KG are developed and produced with spare parts! due regard to all safety precautions. Nevertheless, the unit still causes a number of unavoidable dangers and risks.
  • Page 7: Service And Technical Staff

    EU directive 2002/95/EC on the Restriction of Use of Certain Hazardous Substances in Electrical and Elec- tronic Equipment (RoHS) of 13 February, 2003. Note: Corresponding information concerning the RoHS directive is provided by our firm on the Internet at www.rittal.de/RoHS. Rittal Liquid Cooling Package...
  • Page 8: Device Description

    Air routing on the LCP Rack – top view Air inlet Heat exchanger Fig. 3: Air routing on the LCP Inline flush – top view Air outlet Fan module Air inlet 2nd air inlet Heat exchanger 2nd air outlet Fan module Air outlet Rittal Liquid Cooling Package...
  • Page 9 The dew point can be found in the Mollier h-x diagram (fig. 4). Furthermore, we advise compliance with the ASHRAE standard "ASHRAE TC 9.9, 2011 Thermal Guidelines for Data Processing En- vironments". Rittal Liquid Cooling Package...
  • Page 10 10 º 5 º 0 º -5 º -10 º -15 º Mollier h-x diagram for humid air – pressure 0.950 bar (537.000 m / 10.000 ºC / 80.000%rF) Fig. 4: Mollier h-x diagram for humid air Rittal Liquid Cooling Package...
  • Page 11: Air Routing

    (U) of the 482.6 mm (19") level must be sealed with blanking plates, which are available from Rittal Accessories (see section 15 "Accessories"). As more devices are installed in the server enclosure, it becomes even more important to follow this specification.
  • Page 12: Lcp Inline And Lcp Inline Flush

    Any existing cable entries should be sealed e.g. using suitable brush strips. Whilst the system is in operation, both the front and the rear doors should be kept completely shut. Rittal Liquid Cooling Package...
  • Page 13: Equipment Assembly

    Device/cooling output 30 kW 55 kW LCP Rack 1 module 4 modules LCP Inline 1 module 4 modules LCP Inline flush 2 modules – Tab. 1: No. of fan modules in supplied state Rittal Liquid Cooling Package...
  • Page 14 LCP Rack rear – rear door open LCP rear door Condensate collecting tray and condensate dis- charge Water connection, return Water connection, inlet Air/water heat exchanger Vent valve Mains connection, network connection and connec- tion of optional condensate pump Rittal Liquid Cooling Package...
  • Page 15: Air/Water Heat Exchanger

    Liquid Cooling Package. Three temperature sensors are mounted on the rear of the spray eliminator at the level of the fan modules. Rittal Liquid Cooling Package...
  • Page 16: Water Module With Cold Water Connection

    The cooling water connection to the cold water net- Screws work can be made by either rigid pipework or flexible hoses, which are available from the Rittal accessory A fan module is essentially comprised of the fan itself. range (see section 15 "Accessories").
  • Page 17: Supply Scope Of A Liquid Cooling Package

    3 Device description – Use of replacement parts which are not authorised Unit-specific instructions by Rittal GmbH & Co. KG. 3.6.1 Creation of redundancy in the LCP Rack – Failure to observe the required water quality. Cooling redundancies are easily achieved via the pre- –...
  • Page 18 Cold water system return Fig. 19: Redundant cooling and double alternating water supply LCP Rack Server enclosure Cold water system inlet 1 Cold water system return 1 Cold water system inlet 2 Cold water system return 2 Rittal Liquid Cooling Package...
  • Page 19: Dewpoint Control

    Generally speaking, the dew point monitor should be installed on the outlet side of the unit. Upon approach- ing the dew point, it must be capable of raising the in- let temperature of the cold water or deactivating the cooling via a controller. Rittal Liquid Cooling Package...
  • Page 20: Transportation And Handling

    Use only suitable and technically sound delivery, should immediately be reported to lifting gear and load-bearing devices with the shipping company and to Rittal GmbH & sufficient load capacity. Co. KG in writing. Place the unit in its intended location.
  • Page 21: Assembly And Siting

    The following points are to be considered: – Interfering electrical installations (high frequency) should be avoided. – Heat loss in the adjacent server racks – Air throughput in the adjacent server racks – Distances from the adjacent server racks Rittal Liquid Cooling Package...
  • Page 22: Assembly Procedure

    Rittal accessories (see section 15 "Ac- throughput caused by pressure changes and convec- cessories").
  • Page 23 Seal off any cable entries which may be present with along the entire depth of the devices with corresponding brush strips or similar. sideways air throughput (fig. 22, item 5). Rittal Liquid Cooling Package...
  • Page 24: Dismantle The Server Enclosure Door

    LCP Inline using four of the supplied screws (fig. 25, item 1) each on the left and right. Fig. 23: Removing a door hinge Door hinge Hinge pin holding fixture Hinge joint Server enclosure door Rittal Liquid Cooling Package...
  • Page 25: Fit The Trim Panels If Siting Without A Rear Adaptor

    If necessary, press the LCP Rack or LCP Inline flush Align the Liquid Cooling Package with the server en- lightly against the server enclosure in order to bring closure. Ensure that the Liquid Cooling Package is Rittal Liquid Cooling Package...
  • Page 26: Mounting The Side Panel

    If the Liquid Cooling Package is not bayed between Depending on the required cooling output and in or- two server enclosures, close it off with a side panel. der to form redundancies, up to a maximum of six fan Rittal Liquid Cooling Package...
  • Page 27: Removing A Fan Module

    Fan positions 3 and 4 – Thermally activated switch 3: Fan positions 5 and 6 Note: On the LCP Inline flush, thermally activated switch 3 (fig. 28, item 3) is not assigned and therefore has no function. Rittal Liquid Cooling Package...
  • Page 28 Disconnect the earth connection on the fan (fig. 31, item 3). Loosen the two screws (fig. 31, item 7) on the fan's air baffle plates at the top and bottom respectively. Fig. 32: Rotated fan module in fan tray – LCP Inline flush version Rittal Liquid Cooling Package...
  • Page 29: Installing A Fan Module

    Make the earth connection to the fan. are pointing towards you. Secure the fan module to the mounting plate at the top and bottom using two screws, left and right. Rittal Liquid Cooling Package...
  • Page 30: Install The Optional Display (3311.030)

    Note: If the control unit is incorrectly entered, oper- ation via the display will not be possible. The display will first need to be reset by the Rittal service department. Open the front door of the Liquid Cooling Package. Select the point "CMCII" if a device with a grey front panel marked "CMC-TC"...
  • Page 31: Installation

    No additional control equipment may be Feed the power cable through the conduit fitting and connected upstream of the device at the into the existing strain relief (fig. 38, item 4). supply end. Rittal Liquid Cooling Package...
  • Page 32: Cooling Water Connection

    Insert a suitable screwdriver (blade size 3.5 x 0.5 mm) into an activation opening (fig. 41, item 1) and open the corresponding terminal connection of the conductor entry (fig. 41, item 2). Rittal Liquid Cooling Package...
  • Page 33 2). To do so remove four T25 Screws and then be made with union nuts, even if you choose reinstall them after both hoses have been feed not to use the Rittal hose connection kit. This through. hose connection kit includes suitable union nuts in addition to the connection hoses.
  • Page 34: Connecting The Condensate Discharge

    The Liquid Cooling Package is additionally equipped cur which settle in the pipes and block them. At best, with a condensate discharge (fig. 46, item 3) via organic substances should only be present in small Rittal Liquid Cooling Package...
  • Page 35: Bleeding The Air From The Heat Exchanger

    Route the other end of the hose into a container. Open the ball valve (fig. 47, item 1). Close the ball valve again when no further air bub- bles are visible in the collecting container. The heat exchanger has now been vented. Rittal Liquid Cooling Package...
  • Page 36: Commissioning Checklist

    7 Commissioning checklist Commissioning checklist Rittal GmbH & Co. KG hopes that this checklist will help its customers and cooperation partners install and operate the products of the Liquid Cooling Package family successfully. Before the installation: Are shut-off valves installed in the flow and return?
  • Page 37 482.6 mm (19") level at the sides. Sealing strips are Documenting these parameters helps with available for 2 applications and 2 enclosure widths. error analysis in case malfunctions occur The respective model numbers are found in section during operation. 15 "Accessories". Rittal Liquid Cooling Package...
  • Page 38 7 Commissioning checklist Please feel free to contact Rittal if you have further questions or problems: For malfunctions and repairs Rittal Service Department Tel.: +49(0)2772 505-1855 E-mail: RSI@Rittal-Service.com North American Service Center Tel.: 800-477-4000 E-mail: Service@rittal.us Rittal Liquid Cooling Package...
  • Page 39: Configuration

    If applicable, switch off the proxy server in the browser to facilitate a direct connection to the de- vice. In the browser, enter the address http:// 192.168.0.190 (fig. 48, item 1). The log-on dialogue for registering the device will appear. Rittal Liquid Cooling Package...
  • Page 40: Changing The Measurement Units

    Change the network settings of your computer to the operating parameters, which should only original IP address and subnet mask values. be carried out by Rittal service personnel. Disconnect the network cable from your computer. Using a network cable, connect the device to your computer via the Ethernet LAN.
  • Page 41 This is set in amount per second [1/s] between 0 and 50/s (preset to 0/s). CwValue 1000 9999 Specific thermal capacity of the cooling medium. This value only needs to be ad- justed if the cooling medium used is changed. Rittal Liquid Cooling Package...
  • Page 42 Reserve option. Currently no settings that affect the system. SensorRate Reserve option. Currently no settings that affect the system. FlowCorPar1 Correction factor for water sensors for inlet and return (Grundfos). FlowCorPar2 Correction factor for water sensors for inlet and return (Grundfos). Rittal Liquid Cooling Package...
  • Page 43 Liquid Cooling Package, the water sensors for in- let and return, the flow meter and the con- trol valve must be physically removed from the unit. Otherwise, the internal control components will continue to be regulated. Rittal Liquid Cooling Package...
  • Page 44 Settings cannot be entered via the option- al display with touch function. The "Set- point" entry on the "Settings" screen (fig. 60) is shown in red, whilst the buttons for adjusting the setpoint on the "Setpoint" screen (fig. 62) are masked out. Rittal Liquid Cooling Package...
  • Page 45: Settings

    5 = LCP Inline 60 kW (3311.560) 6 = LCP Inline 30 kW (3311.540) Tab. 4: Settings in the configuration file 8.2.5 Settings All other setting options for the Liquid Cooling Package are described in section 9 "Operation". Rittal Liquid Cooling Package...
  • Page 46: Operation

    As well as the built-in sensors, a wide range of sen- The control unit of the LCP system carries out the fol- sors, actuators and access monitoring systems may lowing functions: be connected via the CAN bus interface. A detailed Rittal Liquid Cooling Package...
  • Page 47: Acknowledging Messages

    15 "Accessories". ature) faulty – Inlet temperature sensor faulty 9.2.2 Acknowledging messages – Return temperature sensor faulty Generally speaking, there are three different ways of – Water module not present acknowledging messages: Rittal Liquid Cooling Package...
  • Page 48: Operation In Stand-Alone Mode

    The user interface of the display with touch function al- Fig. 56: "Home" screen with alarm message lows the user to navigate between the individual menu options of the Liquid Cooling Package controller using software-controlled buttons. Rittal Liquid Cooling Package...
  • Page 49 "Doors" screen. By selecting an entry, e.g. "Door 1", the door magnets on this door output are deactivated for 10 seconds and the door opens. Once this period has expired, the magnet is re-energised. Fig. 59: "Air Info" screen Rittal Liquid Cooling Package...
  • Page 50 "Fan Reg- Fig. 66: "Alarm List" screen istry" screen again. Note: Connect the Liquid Cooling Package to a network for extended setting options (see section 9.3 "Extended options by connecting the Liquid Cooling Package to a network"). Rittal Liquid Cooling Package...
  • Page 51: Automatic Door Opening, Lcp Rack

    With this method, the escape route is only blocked at the back of the server rack. Unauthorised access, is however, possible through the open rear door. The separate partition between the cooling system and the rack is eliminated. Rittal Liquid Cooling Package...
  • Page 52: Extended Options By Connecting The Liquid Cooling Package To A Network

    The separate partition between the cooling system and the rack is eliminated. If the system used is equipped with an automatic door opening feature, the latter must be activated via the LCP software. Rittal Liquid Cooling Package...
  • Page 53: Selection Tree In Left-Hand Section

    Status "Detected". The sensor has recently been added and not yet confirmed. This sen- sor must be confirmed by pressing the "C" button on the CMC III PU or via the Web inter- face. Rittal Liquid Cooling Package...
  • Page 54: Other Displays

    CMC III PU, this is Prohibited symbol Note likewise output in the message display as an error Inactive button message, type "Alarm". Additionally, in such cases, the multi-LED in the front of the CMC III PU will cycli- Rittal Liquid Cooling Package...
  • Page 55: Changing Parameter Values

    An "Edit" symbol will appear, and the mouse pointer One after the other, open the "Liquid Cooling will change to a "Hand" symbol. Package" and "Device" entries by clicking on the "plus" symbol in front of the entry (fig. 71, item 1). Rittal Liquid Cooling Package...
  • Page 56: Logging Off And Changing The Password

    CMC III PU). This may lead to problems when accessing these However, a user can also log off via the Web interface. Rittal Liquid Cooling Package...
  • Page 57: Observation Index Tab

    The following descriptions assume that you have se- lected the tree view. The following sections 9.5.1 "Device" to 9.5.4 "Config" only contain detailed descriptions of those parame- ters which may be altered. There are also display val- ues for information purposes. Rittal Liquid Cooling Package...
  • Page 58: Device

    In-Mid Server inlet temperature, measured at the displayed. You should have this information to hand middle temperature sensor. when contacting Rittal with a query, so as to facilitate In-Bot Server inlet temperature, measured at the rapid error diagnosis. bottom temperature sensor.
  • Page 59 SetLow- Bottom limit of the server outlet tempera- Tab. 17: Settings in sub-levels "Fan1" to "Fan6" Alarm ture; an alarm message is emitted if this is undercut. The following parameters are also displayed for the fans: Rittal Liquid Cooling Package...
  • Page 60: Water

    Bottom limit of the water flow rate; an ceeded. Alarm alarm message is emitted if this is under- cut. SetHigh- Top limit of the water inlet temperature; a Warning warning message is emitted if this is ex- ceeded. Rittal Liquid Cooling Package...
  • Page 61 Tab. 26: Displays at the main "Control-Valve" level Tab. 31: Settings at the main "Condensate Sensor" level Main "Cooling Capacity" level The following parameters are also displayed for con- Cooling capacity settings are carried out at the main densate monitoring: "Cooling Capacity" level. Rittal Liquid Cooling Package...
  • Page 62: Config

    "Changing the measurement units" and 8.2.4 "LCP the control valve are carried out at the main "Control- configuration". All other configuration options are de- Valve" level: scribed in the assembly and operating instructions of the CMC III PU. Rittal Liquid Cooling Package...
  • Page 63: Tasks

    (e.g. "Manual", "Off" or "Full"). Note: Further information on the creation of tasks may be found in the assembly and operat- ing instructions of the CMC III PU. Rittal Liquid Cooling Package...
  • Page 64: Troubleshooting

    If there is air in the system, Bleeding the air from the not providing the water cannot circulate heat exchanger the required properly in the heat ex- cooling out- changer. Thus, it cannot re- move heat. Rittal Liquid Cooling Package...
  • Page 65 Cooling Package. the flow meter is strongly impaired through contami- nants. Improper treatment of the Rittal GmbH & Co. KG rec- water with corrosion pro- ommends the installation of tection additives. filters and the treatment of the water with appropriate corrosion and, if needed, antifreeze additives.
  • Page 66: Inspection And Maintenance

    CMC III PU (if the Liquid Cooling Package is connected to a network). Further- more, the built-in control that is responsible for two fan modules compensates fully in the event of a fan module failure. Rittal Liquid Cooling Package...
  • Page 67: Storage And Disposal

    +70 °C during storage. During storage, the air/water heat exchanger must stand upright. Disposal can be performed at the Rittal plant. Please contact us for advice. Emptying: During storage and transportation below freezing point, the air/water heat exchanger should be drained completely.
  • Page 68: Technical Specifications

    Cooling circuit Cooling medium Water (see Internet for specifications) Coolant inlet temperature [°C] [bar (psi)] 2 to 6 (29 to 88) [bar (psi)] 6 (88) [bar (psi)] 12 (175) Fill quantity [l] Water connection 1½" outer thread Rittal Liquid Cooling Package...
  • Page 69: Lcp Inline Flush

    Cooling circuit Cooling medium Water (see Internet for specifications) Coolant inlet temperature [°C] [bar (psi)] 2 to 6 (29 to 88) [bar (psi)] 6 (88) [bar (psi)] 12 (175) Fill quantity [l] Water connection 1½" outer thread Rittal Liquid Cooling Package...
  • Page 70: Kw Versions

    Cooling circuit Cooling medium Water (see Internet for specifications) Coolant inlet temperature [°C] [bar (psi)] 2 to 6 (29 to 88) [bar (psi)] 6 (88) [bar (psi)] 12 (175) Fill quantity [l] Water connection 1½" outer thread Rittal Liquid Cooling Package...
  • Page 71: External Fuse/Breaker Sizes (Us)

    13.3 External fuse/breaker sizes (US) 208 V 2~ 230 V 1~ Number of fans MCA [A] Max. fuse [A] MCA [A] Max. fuse [A] 12.5 11.3 15.3 13.8 18.0 16.3 Tab. 38: Max. Ampere/pre fuse chart Rittal Liquid Cooling Package...
  • Page 72: Spare Parts

    Flow meter 10-200 3396.691 Temperature sensor, hot/cold air 3396.692 Temperature sensor, water inlet 3396.693 Temperature sensor, water return 3396.694 Fuse box with breaker, EMC filter and power pack Tab. 39: Spare parts list – Liquid Cooling Package Rittal Liquid Cooling Package...
  • Page 73: Accessories

    A de- tailed listing of the complete range of accessories can be found at the Internet address specified in section 20 "Customer service addresses". Rittal Liquid Cooling Package...
  • Page 74: Further Technical Information

    Further technical information 16.1 Hydrological information To avoid system damage and to ensure safe opera- tion, Rittal GmbH & Co KG recommends the use of system water or an additive whose composition does not differ from the hydrological data presented below: pH value 7 –...
  • Page 75: Characteristic Curves

    Number of fans in LCP Fig. 78: Cooling output of the LCP Rack/Inline in the "30 kW" version LCP Inline flush 3311.148/548 (15 ºC water inlet) Number of fans in LCP Fig. 79: Cooling output of the LCP Inline flush Rittal Liquid Cooling Package...
  • Page 76 Cooling output of the LCP Inline flush with three fans LCP Inline flush CW (3311.148/548) with 4 fans (15 ºC water inlet) 20 (1.2) 40 (2.4) 60 (3.6) Flow rate [l/min; (m³/h)] Fig. 81: Cooling output of the LCP Inline flush with four fans Rittal Liquid Cooling Package...
  • Page 77 LCP Rack/Inline CW (3311.268/568) with 5 fans (15 ºC water inlet) 80 (4.8) 100 (6) 120 (7.2) 140 (8.4) Flow rate [l/min; (m³/h]] Fig. 83: Cooling output of the LCP Rack/Inline in the "60 kW" version with five fans Rittal Liquid Cooling Package...
  • Page 78: Pressure Loss

    Device pressure loss LCP Rack/Inline CW, 30 kW (3311.138/148/238/538/548) 20 (1.2) 30 (1.8) 40 (2.4) 50 (3) 60 (3.6) 70 (4.2) 80 (4.8) Water flow rate [l/min; (m³/h)] Fig. 85: Pressure loss of the Liquid Cooling Package in the "30 kW" version Rittal Liquid Cooling Package...
  • Page 79 Device pressure loss LCP Rack/Inline CW, 60 kW (3311.268/568) 20 (1.2) 40 (2.4) 60 (3.6) 80 (4.8) 100 (6) 120 (7.2) 140 (8.4) Water flow rate [l/min; (m³/h)] Fig. 86: Pressure loss of the LCP Rack/Inline in the "60 kW" version Rittal Liquid Cooling Package...
  • Page 80: Overview Drawings

    16 Further technical information 16.3 Overview drawings Fig. 87: Overview drawings of LCP Rack/Inline Rittal Liquid Cooling Package...
  • Page 81 16 Further technical information Fig. 88: Overview drawing of LCP Inline flush Rittal Liquid Cooling Package...
  • Page 82 16 Further technical information Fig. 89: Fan configuration Rittal Liquid Cooling Package...
  • Page 83: Circuit Diagram

    16 Further technical information 16.4 Circuit diagram Fig. 90: Circuit diagram Rittal Liquid Cooling Package...
  • Page 84: Control Unit Hardware For The Fan Modules

    X1 / X2 pin assignment: GND fan 1 CAN 1/2 high SPD_1 actual value, fan 2 CAN 1/2 low GND fan 2 +24 V SPD_3 actual value, fan 3 GND fan 3 SPD_4 actual value, fan 4 +24 V Rittal Liquid Cooling Package...
  • Page 85: Hardware For Startup Current Limitation

    Socket for fan 1, 2 (X1) – 8-pole Flow sensor, inlet Socket for fan 3, 4 (X2) – 8-pole Control valve, inlet Socket for fan 5, 6 (X3) – 8-pole Heat exchanger Earthing (3x) Non-return valve, return Temperature sensor, return Rittal Liquid Cooling Package...
  • Page 86: Preparation And Maintenance Of The Cooling Medium

    For the proper operation of a recooling sys- tem that uses water on at least one side, the composition of any additive used or system water should not deviate substantially from hydrological data presented in section 16.1 "Hydrological information". Rittal Liquid Cooling Package...
  • Page 87: Frequently Asked Questions (Faq)

    Further, this avoids problems arising from condensation and desiccation which results from overcooling. In what output ranges is the Rittal Liquid Cooling Package available? The cooling output of an air/water heat exchanger is How is the airflow in the enclosure achieved and what...
  • Page 88 Connection to the cooling water This achieves considerable savings in the invest- network is made in the floor. Further, Rittal has many ment and operating costs of a data centre. years of experience in the field of air/ water heat ex- changers.
  • Page 89 Whenever the cooling output of the room air condi- server enclosure are standard products within the tioning system is not sufficient to handle the heat Rittal family of enclosures. All components and ac- loads of current high performance servers. With an cessory parts can be used without limitation.
  • Page 90 Does the maximum depth available for installed equipment correspond with the enclosure's depth? Almost the entire depth of the enclosure can be used for installed equipment. No other space for installed mechanical equipment, e.g. fans, is required. Rittal Liquid Cooling Package...
  • Page 91: Glossary

    Fig. 95: "Front to back" cooling principle with bayed LCP Rack Rittal Liquid Cooling Package...
  • Page 92: Customer Service Addresses

    For complaints or service requests, please contact: Tel.: +49(0)2772 505-1855 E-mail: service@rittal.de For customer service in the USA, please contact: Tel.: 800-477-4000 E-mail: Customerservicefax@rittal.us Homepage: www.rittal.us For complaints or service requests in the USA, please contact: Tel.: 800-477-4000 E-mail: Service@rittal.us Rittal Liquid Cooling Package...
  • Page 94 Enclosures Power Distribution Climate Control IT Infrastructure Software & Services vRITTAL GmbH & Co. KG Postfach 1662 · D-35726 Herborn Phone +49(0)2772 505-0 · Fax +49(0)2772 505-2319 E-mail: info@rittal.de · www.rittal.com...

Table of Contents