Fully compatible with fixed and handheld Savi® readers, these tags feature up to 270 feet (82.3 meters) of omnidirectional line-of-sight range. Battery life, using lithium cells, is typically five years. SaviTag ST-614/ST-615 is also certified as safe for operation with live ordnance.
Savi Fixed Reader SR-650-101 or SaviReader 410R. Maximum transmit power: 0.6 mW Air protocol: ST-614 only: EBCS Commands (22-bit tag identification supported) ST-614 and ST-615: Savi EchoPoint Air Protocol 2.1 (32-bit tag identification supported) SaviTag ST-614/ST-615 Installation Guide...
Page 9
Communication range: Up to 12 feet from EchoPoint SP- 651/652-211 Signpost. Up to 3.5 feet from (Intermec) SMR- 650 Mobile Readers. Up to 12 feet (3.66 meters) with Savi Signpost (model SP-65x-xxx) Air protocol: Savi EchoPoint Air Protocol 1.1 Network...
Description: SaviTag ST-614-001 and SaviTag ST 615-001 Onboard memory: 1K Serial EEPROM – User memory Contacting Customer Support If you cannot find the information you need in this guide, contact Savi Customer Support. ◆ Call 1-888-994-SAVI (North America only) or 1-408-743-8888 between 9 a.m.
Page 11
Contacting Customer Support ◆ Send email to help@savi.com. ◆ Check www.savi.com/support for information. When you contact Savi Customer Support by telephone or email, have the following information available: ◆ Contact information (company name, your name, email, and phone number) ◆...
Page 12
C H A P T E R Introduction SaviTag ST-614/ST-615 Installation Guide...
SmartChain Mobile Manager cannot process this command while Note: the Savi Mobile Reader is charging. If the external power supply to the mobile reader is plugged in, you must disconnect it and remove the mobile device from the charging unit to run the command.
Page 14
C H A P T E R Installing SaviTag ST-614/ST-615 Select Enable/Disable Tag UHF Receiver. Savi SmartChain Mobile Manager searches for and displays a list of all SaviTag ST-614/ST-615 within range and indicates if they can be enabled or disabled.
The battery will last approximately three to five years. When the battery is too low to support two complete shipments, the tag will report a low-battery message to the SaviChain software. At that time, the SaviTag ST-614/ST- 615 battery is depleted and the tag must be replaced.
Page 16
SmartChain Mobile Manager cannot process this command while Note: the Savi Mobile Reader is charging. If the external power supply to the mobile reader is plugged in, you must disconnect it and remove the mobile device from the charging unit to run the command.
Placing the Tag Savi SmartChain Mobile Manager searches for and displays a list of all SaviTag ST-654 within range and indicates if they can be enabled or disabled. Select a tag to disable its UHF receiver. Select OK to close the confirmation message.
C H A P T E R Installing SaviTag ST-614/ST-615 SaviTag ST-614/ST-615 will achieve a 270-foot (82.3 m) read range to SR-410 and SR-650 fixed readers. To achieve the most consistent communications with SaviTag ST-614/ST-615, the fixed readers must be mounted: ◆...
◆ Tie-wraps (included in STA-610-RPK) ◆ Twine ◆ Screws Mounting SaviTag ST-614/ST-615 Using Pressure Sensitive Tape The recommended mounting method is pressure-sensitive tape (PST) to attach a SaviTag ST-614/ST-615. The only brand of PST that Savi SaviTag ST-614/ST-615 Installation Guide...
Page 20
Technology recommends for mounting SaviTags is 3M Corporation’s Automotive Acrylic Plus Attachment Tape. For ease of installation, during manufacturing Savi installs this PST on the back of the tag. PST mounting kits are also available for separate purchase. Figure -3 SaviTag ST-614/ST-615 factory installed PST Preparing the Surface for PST Application PST is suitable for almost any smooth, flat surface made of metal or plastic.
Page 21
SaviTag ST-614/ST-615 is to be attached to the shipping container or asset. Be sure that the surface to which the tapes will be applied is flat. Spray a liberal amount of general purpose cleaner onto the mounting surface. SaviTag ST-614/ST-615 Installation Guide...
Page 22
If the surface is heavily soiled, use a mild soap and water solution to scrub the surface clean. Ensure that the mounting surface is free from moisture and condensation. SaviTag ST-614/ST-615 Installation Guide...
PST as outlined in “Removing Pressure Sensitive Tape-Mounted Tags” on page 25. Determine where the SaviTag ST-614/ST-615 is to be attached to the asset. Use a marker to mark on the shipping container or asset the location of the rivet holes on the tag.
Installing SaviTag ST-614/ST-615 Mounting SaviTag ST-614/ST-615 Using Other Methods You can mount SaviTag ST-614/ST-615 using some or all of the fasteners listed on page 19. You will need to provide your own rivets or screws. Figure -6 SaviTag ST-614/ST-615 mounting holes The tag is equipped with a tie-wrap groove to ensure that SaviTag ST- 614/ST-615 is securely fastened.
Removing Pressure Sensitive Tape-Mounted Tags Removing Pressure Sensitive Tape- Mounted Tags Savi recommends that you leave the tag attached to the asset for later reuse, but if it is necessary to remove the tag: Lift one end of the RFID tag with a putty knife or chisel and separate the tape.
Page 26
C H A P T E R Installing SaviTag ST-614/ST-615 SaviTag ST-614/ST-615 Installation Guide...
❖ Corrosive liquids ❖ Peel test (50 pounds of peel force) Savi’s tests confirm the excellent adhesion integrity and reliability of 3M PST. ◆ 3M Corporation conducted a longevity test of PST. They found no significant degradation in the performance of PST even after five years of service on a test vehicle.
Page 28
C H A P T E R Appendix A: PST Reliability and Durability SaviTag ST-614/ST-615 Installation Guide...