EN
FIRST START-UP
FUNCTIONAL VERIFICATION
Make sure that the flexible hoses are well fixed, that too tight bends do not appear and that in any case
they are not crushed for any reason.
Open the water mains taps.
Check that all the hydraulic connections do not show any drips or leaks of any kind.
Dispense natural water until the water without air bubbles has completely flowed out (about 15 liters).
CLEANING
For correct cleaning, wash only with soap and water, rinse and dry with a chamois leather and soft
cloth. Absolutely avoid the use of alcohol, solvents, solid or liquid detergents containing corrosive or
acidic substances, cloths with synthetic fibers, abrasive sponges, pads with metal threads, as they could
irreversibly alter the treated surfaces.
THE USE OF THIS TYPE OF DETERGENTS FOR CLEANING THE TAP INVOLVES ANY WARRANTY ON THE
SURFACE OF THE TAP BY IB RUBINETTERIE.
MAINTENANCE AND CLEANING
REPLACEMENT OF THE PURIFIER FILTER CARTRIDGE
Having ascertained the need to replace the filter cartridge, proceed as follows:
1.
Open the purification box by unscrewing the leaflets.
2.
Close the intermediate valve by turning it counterclockwise.
3.
Dispense natural water to completely drain excess water.
4.
Rotate the cartridge clockwise and remove it.
5.
Take out a new purifier filter cartridge.
6.
Insert the new cartridge at the base of the head, matching the flap with the space made in the ring
nut of the head itself.
7.
Engage and vigorously turn the filter counterclockwise.
8.
Open the intermediate valve by turning it clockwise.
9.
Set the digital meter again.
10. Close the purification box by screwing the leaflets on the lid.
11. Open the natural water completely and wait until the outgoing water is perfectly clear (about 15
liters).
FILTERED WATER IS A KIND OF FOOD AND MUST BE USED WITHIN 1-2 DAYS.