Advertisement

Quick Links

MP Gas Controls S.p.A.
Instructions for installation, use and maintenance
Art. 401
Art. 401
Compile: R.A.
Rev.0 del 01/21
English
Pag. 1 of 11

Advertisement

Table of Contents
loading

Summary of Contents for MP 401

  • Page 1 Art. 401 MP Gas Controls S.p.A. Compile: R.A. Pag. 1 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art. 401 English...
  • Page 2 General Information Installation and Assembling Thermocouple Fixing Gas Inlet and Outlet Connection Chapter 3 - Maintenance General Notes MP Gas Controls S.p.A. Compile: R.A. Pag. 2 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art. 401 English...
  • Page 3: Product Description

    7. Gas outlet 8. Pilot outlet (if present) 9. Production date (year/week or production batch ), and range of temperature 10. Valve code MP Gas Controls S.p.A. Compile: R.A. Pag. 3 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art.
  • Page 4: Technical Properties

    Applications: heating Group: Kind of gas: I, II, III Safety device endurance test : 10.000 (CE) MP Gas Controls S.p.A. Compile: R.A. Pag. 4 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art. 401 English...
  • Page 5: Overall Dimensions

    Art. 401 1.3 - Overall dimensions Indicative dimensions; for more information see assembly drawing. MP Gas Controls S.p.A. Compile: R.A. Pag. 5 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art. 401 English...
  • Page 6: Chapter 2 - Installation

    After installing or replacing the valve / valves, the installer must always check for gas leakage. MP Gas Controls S.p.A. Compile: R.A. Pag. 6 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21...
  • Page 7: Installation And Assembling

    Fix the gas valve on the Carter by the nut , as shown on fig. 1. fig. 1 Nut M12 x 1 (Cod.14307) Carter Ideal torque: 12 Nm Max. torque: 15 Nm MP Gas Controls S.p.A. Compile: R.A. Pag. 7 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art. 401 English...
  • Page 8 Available magnet-on and magnet-off currents: • 200 / 80 mA • 290 / 110 mA • 200 / 40 mA • 180 / 40 mA MP Gas Controls S.p.A. Compile: R.A. Pag. 8 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art.
  • Page 9 Replacement of injector Unscrew the injector to be replaced by the means of an exagonal spanner n°7. Screw-in new injector with a torque of 3,5 - 4 Nm MP Gas Controls S.p.A. Compile: R.A. Pag. 9 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21...
  • Page 10: Chapter 3 - Maintenance

    The parts of the device mounted or adjusted during manufacturing and not intended for manipulation by the user or installer must be adequately protected. Info and contacts MP Gas Controls S.p.A. Compile: R.A. Pag. 10 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21...
  • Page 11 Art. 401 MP GAS CONTROLS S.P.A. VIA NEZIOLE 2 25055 - PISOGNE (BS) - ITALY +39 0364 89020 info@mpgascontrols.com MP Gas Controls S.p.A. Compile: R.A. Pag. 11 of 11 Instructions for installation, use and maintenance Rev.0 del 01/21 Art. 401...

Table of Contents