Page 3
Self sealing pressure module connection to prevent fluid leaks. • Fast thermal stability for devices connected directly to the test port connection, less than one minute. Optional extra. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | i...
Page 4
This includes: the applicable local safety procedures, this publication, and the instructions for the accessories, options and equipment you are using it with. Read more safety conditions in the 132M9252 safety guide. Copyright 2022 Baker Hughes Company. ii | PV 62X / PV 62X-IS Instruction Manual–English...
Hydraulic pressure release valve. Use to release all pressure in the system. Unscrew the valve fully to access the hydraulic fluid reservoir. Hydraulic priming pump. Refer to Section 5.3 for filling and priming instructions. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 1...
The test port uses “Quick fit” pressure adaptors. These are easy to remove, change and install. The “Quick fit” adaptors are available in NPT and BSP (parallel) thread types. Adaptors for other thread types are available from Druck. Copyright 2022 Baker Hughes Company. 2 | PV 62X / PV 62X-IS Instruction Manual–English...
Make sure that there are no missing items. Note: Use only original parts supplied by the manufacturer. Refer to Chapter 1 for a description of the pressure station controls. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 3...
To do equal adjustments (up or down) at the end of the procedure, turn the volume adjuster to the middle of its range of operation. Close the pressure release valve clockwise. Copyright 2022 Baker Hughes Company. 4 | PV 62X / PV 62X-IS Instruction Manual–English...
Note: To get the maximum vacuum, turn the volume adjuster fully clockwise. Close the pressure release valve clockwise. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 5...
This chapter gives instructions on how to operate the PV 623G / PV 623-IS pressure station to supply the necessary pressure. Before you start: • Read and understand “Safety” on page ii. Copyright 2022 Baker Hughes Company. 6 | PV 62X / PV 62X-IS Instruction Manual–English...
Note: To prevent contamination use only one type of hydraulic fluid in the pressure station. Replace the pressure release valve. Turn fully clockwise until firmly shut. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 7...
Connect the equipment under test to the PV 623G / PV 623-IS test port, see Chapter 2. Make sure that the reservoir contains sufficient hydraulic fluid; see Section 5.3. Use the following steps to set the necessary pressure. Copyright 2022 Baker Hughes Company. 8 | PV 62X / PV 62X-IS Instruction Manual–English...
Close the refill valve fully clockwise (finger tight only). Note: Closing the refill valve seals off all pressure in the test port and the pressure module connection. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 9...
Applicable skin and eye protection. • A sufficiently large container to hold the hydraulic fluid. • Applicable materials to clean the pressure station, refer to Chapter 7. Copyright 2022 Baker Hughes Company. 10 | PV 62X / PV 62X-IS Instruction Manual–English...
The correct PRV helps prevent overpressure and damage to the equipment under test. To adjust the PRV, see Section 6.3. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 11...
This chapter gives procedures to maintain the unit in a good condition. 7.2 Repair Do not do repairs to this equipment. Return the equipment to the manufacturer or an approved service agent. Copyright 2022 Baker Hughes Company. 12 | PV 62X / PV 62X-IS Instruction Manual–English...
Page 19
• Channel Settings: Units = Bar; Utility = Leak Test • Settings: Test Time = 00:01:00 (1 minute) Let the pressure become stable for 1 minute. Copyright 2022 Baker Hughes Company. English–PV 62X / PV 62X-IS Instruction Manual | 13...
Page 22
700 bar (10,000 psi) 300 to 700 bar (4,350 to 10,000 psi) IO620-PRV-H5 Hydraulic 1000 bar (15,000 psi) 600 to 1000 bar (8,700 to 15,000 psi) Copyright 2022 Baker Hughes Company. 16 | PV 62X / PV 62X-IS Instruction Manual–English...
Page 24
Copyright 2022 Baker Hughes Company. This material contains one or more registered trademarks of Baker Hughes Company and its subsidiaries in one or more countries. All third- party product and company names are trademarks of their respective holders. bakerhughes.com...