    OPOP, LLC Zašovská 750, 757 01 Valašské Meziříčí Tel.: 571 675 589, fax: 571 611 225 WATER HEATER H 425 EKO Content Introduction Characteristics of the water heater Technical description Technical parameters List of replaceable parts List of supplied accessories...
  • Page 2: Introduction

    - by careful reading the manual and by complying with all prescribed rules and regulations. OPOP, LLC 2 . CHARACTERISTICS OF THE WATER HEATER The design and surface of the steel water heater of the H4xx EKO line are designated for individual and central heating of family houses or suitable production facilities with a maximum hydrostatic height of the heating water of 20 m.
  • Page 3 a) The front area behind the boiler head wall is formed by a feeding shaft with a cast-iron, sliding grate. b) The middle part forms the burning area, padded with a fireclay lining and a stainless steel pipe, through which about 40% of secondary air flows. The remaining 60% of the air flows through two side openings, located immediately under the first water plate.
  • Page 4 Picture B Note - A great advantage of the perfect burning of this boiler is the fact that the secondary air, which we can regulate by the above mentioned revolving valves, is preheated! Preheating takes place in the air chamber, which forms a part of the boiler body. It means that the air that enters the fire chamber and the area between the partitions does not have the temperature of the surrounding environment °C °C...
  • Page 5: Technical Parameters

    position. This position is marked by a line for an easy orientation – see Picture C. The power output of the boiler can be increased by making the opening gradually bigger. Picture C The mouthpiece for adding water as well as the smoke hub are located on the center axis of the rear part of the boiler.
  • Page 6 Parameter name Unit Coal Wood Operational draft - prescribed Table 2 Operational draft - minimal Nominal heat output [kW] WATER HEATER H425 EKO Efficiency 79.4 79.3 Boiler class pursuant to ČSN EN 303-5 Boiler weight [kg] Split Mouthpiece type output / input (internal thread) G1 1/2"...
  • Page 8 Daiagram: DRAFT REGULATOR, MANOMETER, COOLING LOOP, THERMOMETER Table: Position Part name Quantity Position Part name Quantity H425 EOK boiler Grate mechanism body Secondary pipe Sliding cast-iron grate Cleaning lid Slanting cast-iron grate Manometer Fireclay fitting II (30x275x400) Side cover (left) Fireclay fitting I (30x100x400) Front cover...
  • Page 9: List Of Replaceable Parts

    5. List of replaceable spare parts List of spare parts Position of the spare part from page 8 Stoking door Cleaning door Ash door Slanting cast-iron grate Sliding cast-iron grate Stoking valve plate / stoking valve pin 28, 29 Cleaning lid Grate mechanisms Ash drawer 10) Front cover...
  • Page 10: List Of Supplied Accessories

    6. List of supplied accessories Scraper and hook for cleaning boiler surfaces Broom (holder + steel brush) Filling valve Draft regulator for combustion air Manometer MCS 48, Thermometer TSC 48 Security thermal valve TS 130 or STS 20 (not a part of the package) Lever of the grate mechanism Operating manual with a warranty sheet Cleaning lid...
  • Page 11 b) Installing fireclay lining and the secondary pipe: Because the fireclay lining could get damaged during transportation, these fitting are delivered in a separate package. After the boiler is placed in its location and connected to the given system, insert the fireclay fittings in it in accordance with Picture E.
  • Page 12: Water Heater Operation

    8. Water heater operation Prior to starting the fire for the first time, the following has to be done: Making sure that the boiler and the entire heating system is filled with water or some other heat-conducting medium and correctly deaerated. Making sure that the drafting routes are sealed.
  • Page 13: Ash Removal

    Note: Upon reaching the required temperature of the output water (for example, 80 C), release the chain on the holder of the regulator and set such a length that the valve is open only 2-3 mm. In this way, the regulator will maintain the required temperature of the boiler. We do not recommend setting the valve in a way that the suffocating lid on the stoking door is completely closed.
  • Page 14: Maintaining The Water Heater And The Heating Apparatus

    8. The cleaning lid closes the area between the rear air hole of the partition and the ash drawer. Next, take out the fireclay lining with the secondary pipe from the boiler. Clean the pipe thoroughly. Using the scraper and the steel brush, scrape off ash and soot from the boiler walls.
  • Page 15: Safety Instructions For The Assembly And Operation Of The Water Heater

    The manufacturer recommends installing a suitable mixing device in the heating circle, especially when using a circulation pump, in Note: order to make sure that the input temperature of the heated water in the boiler does not drop under 65°C. Water hardness must comply with ČSN 07 7401.
  • Page 16: Assembly Of The Discharge Valve

    Note: The longer the burning period after grating, the smaller volume of secondary air is necessary, and vice versa. 10.2 Assembly of the discharge valve At the rear bottom part of the boiler, a ½” mouthpiece is welded. Screw (and pack) the discharge valve into it.
  • Page 17: Sorting Construction Products And Structures Based On Their Reaction To Fire

    should rise toward the chimney; the recommended slant is at least 5% (3°). We also recommend that it is attached directly - no more than one pipe elbow. The water-heating system must be executed in accordance with ČSN 06 0310:2006 (Central Heating, Project Design and Assembly), ČSN 06 0830:2006 (Security Devices for Central Heating and Service Water Heating), ČSN 07 7401 (Water and Steam for Thermal Energy Devices with Steam Working Pressure up to 8 MPa, ČSN EN 303-5 (Boilers for Central Heating –...
  • Page 18: Instructions For Assembling And Using Pressurized Expansion Containers

    The boiler must be installed on a non-flammable, thermally insulating mat that overlaps the boiler on the side of the ash doors by at least 300 mm and by at least 100 mm on the other sides. If there is a possibility of a temporary occurrence of flammable gases or vapors, or during works when a temporary fire hazard or explosion hazard could arise (for example, when pasting linoleum, PVC, etc.), the appliance must be shut down prior to the occurrence of such a fire hazard.
  • Page 19: Connecting The Water Heater To A Protection Device Against Overheating

    measured using a manometer for measuring tire pressure. By adding water, adjust the pressure to a value that is higher by 10 kPa, at the most, than the hydrostatic height in the system. 8) Once you fill the system with water, mark the adjusted hydrostatic height and maximum pressure in the system upon reaching water temperature of 90°C by drawing the appropriate lines on the manometer.
  • Page 20 Cooling loop connection: Combustion air draft regulator Picture F Safety valve sensor Cooling loop Discharge of the cooling water Mouthpiece for attaching a safety valve against overheating...
  • Page 21: Safety Instructions For The Water Heater Operation

    Operating principle: slide the safety valve sensor into the shaft in the upper rear part of the boiler where it monitors water temperature in the boiler. If the temperature reaches 95°C (TS 130) or 97°C (STS 20), the valve automatically begins to open and lets water into the built-in safety exchanger, which collects heat and prevents overheating of the boiler.
  • Page 22 It is forbidden to use flammable liquids for starting fire in the appliance and to increase, in any manner whatsoever, the boiler’s nominal output during its operation (thermal overloading). Users are allowed to conduct only common maintenance and, if necessary, to replace delivered spare parts.
  • Page 23: Waste Removal

    Minimal recommended operational temperature is above 65 °C. If the temperature is lower, water steam can condensate in the burnt gases, which can have a negative impact on the correct operation of the boiler and its lifespan. In order to secure safe and economic operation of the boiler, there are several important principles that you should comply with: ...
  • Page 24: Determining The Size Of The Accumulation Reservoir

    Used packaging material complies with the requirements for packages specified by Act No. 477/2001 Sb., on Packages and on changes of some other Acts, as amended.  12. Determining the size of the accumulation reservoir Formula for determining the minimal volume of the reservoir: Vsp = 15 Tb x Qn (1-0.3 x (QH/Qmin)) Where: Vsp …..
  • Page 25: Safety And Other Regulations

    Water in the boiler is boiling: Big hydraulic resistance of the heating system, especially in the case of a self-loading system; Excessive draft in the chimney – reduce the draft; Clean the heating system by rinsing or, if necessary, install a circulation pump. 15.
  • Page 26 Warranty conditions: 1. H4eko boilers can be installed only by a company with a valid authorization to perform its installation and maintenance. 2. Installation project must be elaborated in accordance with applicable regulations. 3. The heating system must be filled with water, which meets the requirements of ČSN 07 7401 and especially its hardness must not exceed the required parameters.
  • Page 27 14. Boiler manufacturer is responsible for fuel quality in terms of combustion quality, the amount of ash, intervals for cleaning. These facts only affect the external factors such as the quality of pellets, dust and moisture in the pellets, chimney draft and correct setting of the combustion process. 15.
  • Page 28 26. The manufacturer is not liable for damage caused by handling, shipments, incorrect settings or improper use or other external factors, which are not directly caused by the individual components operation. 27. Installation company that sold the boiler to the end customer is always responsible for proper installation, boiler setup and activation.
  • Page 29: Warranty Card

    WARRANTY CARD For Water Heater H 425 EKO Manufacturer: OPOP, LLC, Valašské Meziříčí, Tel.: 571 675 589, fax: 571 611 225 Date of the expedition from the factory:________________________ Warranty conditions: The user shall be obliged to have a professional service company to put the device into operation, to conduct regular maintenance and repairs This warranty card includes quality and completeness certificate.
  • Page 30 Warranty extenstion Custommer‘s name: Boiler name: ____________________ Adress: _______________________Serial number: __________________ City: _________________________Instalation date: _________________ Answer all questions below by YES or NO or parameter value each year. Fill additional information if necessary. First Question: startup Year +1 Year +2 Year +3 If NO, write a reason Is the boiler operated at maximum...
  • Page 31 OPOP, LLC Zašovská 750 757 01 Valašské Meziříčí Bank contact: Komerční Banka a.s., Account number: 1608851/0100 Business Identification Number: 47674105, Tax Identification Number: CZ 47674105 Telephone: Business Department: 571 675 589, Secretary: 571 611 250, Production: 571 675 405 Supplies: 571 675 114, Financial Department: 571 675 472...