Summary of Contents for SmartRoom SR-ZSPWBPW-PI11-01

  • Page 1 SmartRoom 红外入侵探测器 SR-ZSPWBPW-PI11-01 产品使用说明书 ©2015 南京物联传感技术有限公司 出版号:2015-0505.V01...
  • Page 2 欢迎您使用SmartRoom红外入侵探测器产品说明书 ● 是南京物联传感技术有限公司的注册商标。本手册中提到的所有 其他产品名称或商标是其各自品牌所有者的商标或注册商标。 ●使用前请您认真阅读产品使用说明书,确保正确地、安全地使用。 ●SmartRoom红外入侵探测器产品(以下简称“本产品”)为南京物联传感技术 有限公司(以下简称“我司”)出品的智能家居安防类产品。本产品需要与智能 家居相应APP客户端同步使用,并须使用本产品自带的配件,如您未正确地安装 及使用本产品,而造成的损失,我司将不承担任何责任。 ●我司随时可能对本说明书中的产品信息进行更新,恕不另行通知。请您及时 关注我司资讯,并下载最新版的APP客户端。 ●未经我司的明确书面许可,任何个人及企业不得复制本说明书的全部或部分内 容,不得使用我司注册商标。对非法使用我司商标的行为,我司将依法追究行为 人及企业法律责任。 ●欢迎您登录我司官网www.wulian.cc,了解更多智能家居产品信息。...
  • Page 3 功能图示 多功能按键 系统指示灯 磁铁 入侵感应区 电池盒 主体正面 底座 主体背面...
  • Page 4 产品特点 ●通过APP客户端,可进行远程操作及监控。 ●设防状态下,当探测到警戒范围内移动物体时,报警信息可第一时间传送至 客户端,且能够与相关报警设备联动使用,多重设防。 ●用无线传输方式报警,反应迅速,抗干扰能力强,误报率低。 ●环境温度变化自动补偿灵敏度。 ●探测角度可自由调节,探测范围广、且调节方便快捷。...
  • Page 5 软件下载 下载方式一: 请扫描产品包装盒上的二维码,下载软件客户端。 下载方式二: 官网下载:http://www.wulian.cc/service.shtml 温馨提示:初次使用时,请先安装APP客户端,并仔细阅读产品说明书;请时 常关注我司资讯,以便及时更新。...
  • Page 6 安装步骤 注:建议将本产品安装在距离地面约2.4m-4m的位置; 安装方式一:可直接放置于任何固定的平面使用。 安装方式二:墙面/吸顶安装 第一步:在墙面/顶面预定位,装入两颗膨胀管;再用自攻螺丝将底座固定。 底座 膨胀管 螺丝 墙面&顶面...
  • Page 7 第二步: 打开电池盖,装入一粒CR2电池后卡上电池盖。 CR2电池 电池盖 主体背面...
  • Page 8 第三步:将本产品主体直接吸扣在底座上,并调整至合适角度,安装完成。 注:安装完成前,请先进行联网设置。 墙面&顶面...
  • Page 9 联网设置 1、加网设置 快击【多功能按键】4次,单次快击时间不超过1秒,申请加入ZigBee网络,搜网 过程中【系统指示灯】呈绿色闪烁;成功加入ZigBee网络后,【系统指示灯】呈 绿色长亮2秒后熄灭。 快击4次 (单次快击时间不超过1 秒) 搜索网络时,【系统指示灯】 闪烁;成 功 入 网 后 , 长 亮 2 秒熄灭 主体正面 主体背面...
  • Page 10 2、退网设置 长按【多功能按键】10秒,【系统指示灯】闪烁4次后熄灭,恢复出厂设置, 同时退出ZigBee网络。 长按10秒 【系统指示灯】闪烁4次后熄灭 主体正面 主体背面...
  • Page 11 备注: ●设置前,请确认无线网关(需另外购买)ZigBee网络正常工作。同时,请确 认本产品处于通电状态,且处于网关的有效通信距离内。 ●当本产品需要加入到其他网关时,请先退出当前网关,再进行联网设置。 ●恢复出厂设置默认为不加入ZigBee网络。...
  • Page 12 如何使用 正常工作情况下,【系统指示灯】不闪烁;设防状态下,一旦有移动物体进入探 测区,【系统指示灯】呈红色闪烁1次,同时向移动智能终端发出报警信息。...
  • Page 13 注意事项 ●本产品安装高度须按照说明书规定的范围,以免安装过高或者过低,影响探 测角度和探测距离,探测范围内避免有隔屏、家具、大型盆景或其他隔离物, 建议不要安装在有强气流活动位置。 ●本产品应远离空调、冰箱、火炉等空气温度变化敏感的地方,建议不要安装 在有强气流活动位置,防止窗外的热气流扰动和人员走动引起信号误报。 ●本产品需定期进行例行试验,发现故障并及时排除,以免有盗情不报警。 ●本产品切勿跌落、撞击,以免损坏内部器件。 ●请勿擅自拆卸或改装本产品及其配件。 请更换正确型号的电池,以免有爆炸危险!请按照操作指示处理废旧电池!...
  • Page 14 产品参数 IEEE 802.15.4 ZigBee/SmartRoom 通信协议 直径为6米的圆周(安装高度为3米) 探测范围 一次事件 探测灵敏度 0.2~3.5m/s 探测速度 30μA 待机功耗/待机电流 2.3-5 安装高度范围(m) DC 3V CR2*1 电源参数 64×38 外形尺寸(直径×厚度,mm) 净重(g) PC+ABS,白色 材质颜色 UL94 V-2 阻燃等级 -10℃~45℃ 工作环境温度 ≤95%RH (不凝结) 工作环境湿度...
  • Page 15 订购信息 产品名称 SmartRoom红外入侵探测器 产品型号 SR-ZSPWBPW-PI11-01 材质/颜色 PC+ABS,白色 货号 SRPN1311301...
  • Page 16 南京市雨花台区凤集大道15号创业创新城-北柚11栋 邮编:210039 服务热线:400-928-9288 官网:www.wulian.cc...
  • Page 17 SmartRoom ISO9001:2008 Certified Smart PIR Motion Detector SR-ZSPWBPW-PI11-01 User Manual ©2015 Nanjing IOT Sensor Technology Co., Ltd. Publication No.:2015-0505.V01...
  • Page 18 Federal Communications Commission (FCC) Compliance Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 19 Federal Communications Commission (FCC) Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference.
  • Page 20 ●Please read this manual carefully and keep it properly before using. ●SmartRoom Smart PIR Motion Detector (hereinafter referred to as “this product”) is smart home security product produced by Nanjing IOT Sensor Technology Co., Ltd. (hereinafter referred to as “Wulian”).
  • Page 21: Function Illustration

    Function Illustration Multi-functional Key System Indicator Magnet Detection Area Battery Compartment Base Back of body Front of body...
  • Page 22 Features ●Realize remote monitoring and management via APP Client. ●In the state of “Armed”, when motion is detected in detection area, the mobile smart terminal would receive alarm notifications immediately. This product could also interwork with security devices to secure your home in all aspect. ●The quick and interference-free wireless transmission of alarm notification could lower the false alarm rate.
  • Page 23: Software Download

    Software Download Option A: Download the latest smart APP by scanning QR code on the package box of this product. Option B: iOS user can download the APP by searching "Wulian Smart home" in "APP Store". Android user can download the APP by searching "Wulian Smart home" in "Google Play".
  • Page 24: Installation Instructions

    Installation Instructions Note: it is recommended to install this product 2.4m to 4m above ground. Option A:Place it on any fixed flat surface Option B:Wall/Ceiling-mounted Step One: Mount two expansion plugs on the desired location of the wall/ceilings. Then fix the base with the self-tapping screws. Base Expansion plug Self-tapping screw...
  • Page 25 Step Two: Open the cell cover and load put in a CR2 battery. CR2 battery Cell Cover Back of Body...
  • Page 26 Step Three: Attach the body directly to the base and adjust it to a suitable angle to complete the installation. Note: Set the network before installation is completed. Wall/Ceiling...
  • Page 27: Network Setting

    Network Setting 1. Add to network Click [Multi-functional Key] 4 times quickly and [System Indicator] would flash green to request to add to the ZigBee network. Then [System Indicator] goes out after staying green for 2s when it is added to the ZigBee network. Flash in searching for the network Click [Multi-functional Key] 4 times Goes out after staying on for 2s...
  • Page 28 2.Exit the network. Press on [Multi-functional Key] for 10s and [System Indicator] goes out after flashing 4 times to exit the ZigBee network successfully and restore to factory settings at the same time. Press on for 10s Goes out after flashing 4 times Back of Body Front of Body...
  • Page 29 Note: ●First make sure ZigBee network of the wireless gateway (additional purchase) is working well. Meanwhile, make sure this product is connected to power and is placed within the effective communication distance of the gateway. If remote control is needed, connect the gate to WAN. ●When this product need adding to other gateways, please exit the current gateway and then set networks.
  • Page 30 User Guide On normal conditions, [System Indicator] would not flash. In the state of “armed”, once motion is detected in detection area, [System Indicator] would flash red for once. And at the same time, the mobile smart terminal would receive alarm notification.
  • Page 31 Cautions ●This product shall be installed according to the height specified in the user manual. Installing too high or too low would cause adverse effect to the angle and distance of detection. The shield, furniture, potted plant and other partitions shall not be placed in the detective range of this product.
  • Page 32: Specifications

    Specifications IEEE 802.15.4 ZigBee/SmartRoom Communication Protocol Circumference with 6m of Diameter Detective Range ( Installation Height 3m) Once Detective Sensitivity 0.2~3.5m/s Detective Speed 30μA Standby Consumption/Standby Current 2.3-5 Mounting Height(m) CR2*3V Power Supply 64×38 Dimensions(Diameter×Height, mm) Net Weight(g) PC+ABS,White Material& Color...
  • Page 33: Purchase Information

    Purchase Information Product Name SmartRoom Smart PIR Motion Detector Product Model SR-ZSPWBPW-PI11-01 Material/Color PC+ABS,White Item No. SRPN1311301...
  • Page 34 Statement: Hereby, declares that this device is Nanjing IOT Sensor Technology Co., Ltd. in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Disposal and Recycling Information You can help protect the environment! Please remember to respect the local regulations:hand in the non-working electrical equipments to an appropriate waste disposal centre The following marking is included in the product : 0700...
  • Page 35 Building 11, No.15, Fengji Road, Yuhuatai District, Nanjing (P. C.: 210039) Email: overseas@wuliangroup.com Service Hotline: 400-889-2891 www.wulian.cc/english...