The Fuel Suction System is specifically designed to convey 6 mm diameter pellets from a main silo to a cyclone on a boiler reserve tank, providing it is installed together with a suction system (a DOMUSA TEKNIK Kit Spider) or a DOMUSA TEKNIK prefabricated textile silo including a pneumatic extraction device (cyclone) or a DOMUSA TEKNIK suction nozzle kit for on-site tanks..
There is a ventilation slot on the rear of the tank to prevent a vacuum from being created inside it. Do not cover this slot, and keep it free from any obstacles that could block it. Do not cover BIOCLASS iC 66 | HC...
Page 7
If you are using a Kit Spider removal system, it is not essential to run the return hose to the silo, but we recommend doing so to prevent the areas the hose opens onto from getting dirty. BIOCLASS iC 66 | HC...
Page 8
Before carrying out any work on the boiler's electrical installation of the Fuel suction system, always ensure the boiler is disconnected from the mains. Make sure that none of the cables come into contact with a hot surface (e.g. fireplace or smoke chamber). BIOCLASS iC 66 | HC...
For correct assembly of the hoses, they should be fixed to the walls and/or floor using suitable fasteners throughout the entire installation, to ensure stability. The recommended maximum distance between the fixing points is 80 -110 cm. BIOCLASS iC 66 | HC...
Page 10
IMPORTANT: must be connected to the earth connection terminals provided for this purpose. DOMUSA TEKNIK will hold no liability for malfunctioning of the Fuel Suction IMPORTANT: System if the installation does not comply with the above recommendations. BIOCLASS iC 66 | HC...
To ensure the correct working of the suction system, cover or clear the slots of the aerator until optimal extraction is achieved IMPORTANT: It is essential to ensure that both sections of the suction pipe are earthed BIOCLASS iC 66 | HC...
2.4 Start-up In order for the guarantee to be valid, the Fuel suction system must be started up by personnel authorised by DOMUSA TEKNIK. Before beginning the start-up process, the following must be complied with: The Fuel Suction System must be connected to the electrical mains power.
“On”. The periods adjusted with " “symbol will be marked in the time zone of the top of the display. Press to record the last timer adjustments and it returns to "Configuration" menu. BIOCLASS iC 66 | HC...
3.2 Functioning with a Textile Silo or Suction noozle In the case of an installation with a fabric silo or suction nozzle kit supplied by DOMUSA TEKNIK, the suction turbine will be activated every time the cyclone sensor detects a lack of pellets and will remain in operation during the cycle time set by the user in parameter P.22 of the “Technician”...
3.3 Functioning with a Kit Spider If the installation is made in combination with the Kit Spider pellet removal system of DOMUSA TEKNIK, whenever the tank filling sensor detects that the pellet level is low, the electronic control will begin each cycle by starting up the suction unit and Kit Spider motor at the same time, turning the kit’s rotary...
Page 17
If the suction system becomes blocked, this could mean there are insufficient NOTE: pellets in the main silo or that the pneumatic hose installation has become blocked or is defective. BIOCLASS iC 66 | HC...
Also, to ensure correct functioning of the boiler we recommend inspection of the whole pellet loading system once a year by the DOMUSA TEKNIK Authorised Technical Service, at the same time as the annual service.
You must remove the suction turbine and clean it using a compressed air or vacuum cleaner. The motor of the suction turbine has carbon brushes. Replace the brushes when the consumption reaches approximately 55 tones of pellet. BIOCLASS iC 66 | HC...
6 TECHNICAL DATA TECHNICAL CHARACTERISTICS VALUE Maximum suction length Maximum suction height Suction hose diameter Connection voltage 230 V ~ 50 Hz Maximum electrical consumption Maximum electric power 1700 BIOCLASS iC 66 | HC...
7.2 Electrical connection for installation with a DOMUSA TEKNIK Textile Silo Boiler power supply board 14 13 N 12 11 10 9 N 8 N N 6 Fuel suction system power supply cable Fuel suction system communication cabl Brown Blue...
7.3 Electrical connection for installation with a DOMUSA TEKNIK Kit Spider Communication connector. Kit Spider connector Filling sensor connection. J10: Fuel suction system connector. J11: BIOCLASS iC 66 | HC...
Place the cover over the filling hole as shown in the latches. figure. Use the transportation handle to carry the ash Remove the lid using the latches and empty the ash. drawer. Replace the ash drawer, ensuring it is hermetically sealed. BIOCLASS iC 66 | HC...
The ash drawer must be emptied with the boiler switched off. Never touch the screwas it could trap your hand. DOMUSA TEKNIK shall not be liable for any injury or damage caused to people, animals or property as a result of incorrect handling of the ash drawer or the ash itself.
Page 27
NOTES: ......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................BIOCLASS iC 66 | HC...