This specification describes the type, dimension, performance, technical characteristics, warnings and cautions of the lithium ion recharge-
able cell. The specification only applies to N 18650CP cell supplied by energy inside.

2 Definition

2.1 Standard charge method
At 25 ± 2°C, the cell is charged to 4.2 V at constant current of 0.5 C (1625 mA), then charged at constant voltage of 4.2 V until the current
tapers to ≤ 0.01C (32 mA) followed by resting for 5 min.
2.2 Standard discharge method
Under 25 ± 2°C, the cell is discharged to 2.5 V at a constant current of 0.2 C (650 mA).
2.3 Nominal capacity
Nominal capacity, signed as capacity and using mAh as unit, is obtained by discharging a cell via standard discharge method after it is stan-
dard charged.

3 Cell model and dimensions

3.1 Description and model
Description: Cylindrical Li-Ion rechargeable cell
3.2 Cell dimensions
Cell physical dimensions listed in Figure 1 (unit: mm), withtube

4 Cell characteristics

Unless otherwise specified, the cell is fresh cell and tested by standard charge and standard discharge.
Nominal capacity
Minimum capacity
Nominal voltage
Charge cut-off voltage
Discharge cut-off voltage
Max charge current
Max discharge current
Storage temperature
Humidity range
Internal resistance
Weight
www.energyinside.de
www.energyinside.de
Specification for Lithium-Ion Rechargeable Cell
XCell N18650CP-35E
3350mAh by standard charge and discharge
3250mAh by standard charge and discharge
3.6 V
4.20 V
2.50 V
1C (25°C, not for cycle life)
3C (25°C, not for cycle life)
1 year: -20~25°C
3 months: -20~45°C
1 month: -20~60°C
0 ~ 60% RH (non-condensing)
≤ 35 mΩ (AC Impedance, 1000 Hz)
≤ 49g
148187

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N18650CP-35E and is the answer not in the manual?

Questions and answers

Summary of Contents for XCell N18650CP-35E

  • Page 1 148187 Specification for Lithium-Ion Rechargeable Cell XCell N18650CP-35E 1 Preface This specification describes the type, dimension, performance, technical characteristics, warnings and cautions of the lithium ion recharge- able cell. The specification only applies to N 18650CP cell supplied by energy inside.
  • Page 2 148187 www.energyinside.de 5 Technical requirements 5.1 Cell operating conditions Charge temperature 0 ~ 45°C, Discharge temperature -20 ~ 60°C 5.2 Cell testing conditions Unless otherwise specified, all tests stated should be done at 25 ± 2°C. 5.3 Requirement of the testing equipment The voltage measurement device: not less than 0.5 grade The current measurement device:...
  • Page 3 148187 www.energyinside.de 5.5 Environmental and safety characteristics 5.5.1 Vibration No fire, No explosion, No leakage, The maximum mass loss ≤0.1% After standard fully charge, cell shall be attached to a vibration table directly and subjected to vibration that consists of 10 Hz to 55 Hz to 10 Hz at the speed of 1Hz/min in 90~100mins.The total excursion of the vibration is 0.8mm (0.060 inches).
  • Page 4 148187 www.energyinside.de 6 Package picture Small box / Big box / Pallet (100pcs cells in a small box, 2 small boxes in a big box) 7 Shipment The cell shall be shipped in voltage range of 3.5 ~ 3.8 V or in accordance with customers‘ requirement. The remaining capacity before char- ging shall be changed depending on the storage time and conditions.
  • Page 5 148187 www.energyinside.de Do not disassemble or modify the cell. Do not transport or store the cell together with metal objects such as necklaces, hairpins, coins, etc. Make sure the cell is not with conspicuous damage or deformation. 10 Don’t connect the cell to an electrical outlet directly. 11 If the cell leaks and the electrolyte splashes into the eyes, rinse the eyes with clean running water immediately for at least 15 minutes, and go to hospital for treatment if necessary.

This manual is also suitable for:

148187

Table of Contents