We would like to thank you for your purchase of an Aurora Suspended Fire. The care and craftsmanship we put into each fire will give you trouble free heating for many years to come. CONTENTS 1. PLANNING INTRODUCTION CLEARANCE TO COMBUSTIBLES 2.
6. Insert the burner and glass fire screen Mixing of appliance or flue-system components from different sources or modifying the dimensional specification of components may result in hazardous conditions. Where such action is considered, Aurora fires should be consulted in the first instance.
AURORA SUSPENDED FIRES CLEARANCE TO COMBUSTIBLES A combustible surface is anything that can burn (i.e. plaster, wall paper, wood, fabrics etc.) These surfaces are not limited to those that are visible, but also include materials that are behind non-combustible material. Timber frames behind gyprock are considered combustible.
Page 7
AURORA SUSPENDED FIRES THE ZENTAI FEATURES WEIGHT & DIMENSIONS · Material: 3mm Steel Base Diameter 900mm · Finish: high temperature Hood Height 1250mm coating system Base Weight 37kg · Heat Output: 5.99kW Hood Weight 55kg · Colour: matte black (A range of other colours are...
Page 8
DIMENSIONS & SPECIFICATIONS INSTALLATION AND USER MANUAL CEILING BRACKET FLUE HOOD BASE...
INSTALLATION INSTALLATION AND USER MANUAL SUSPENSION BRACKET FLAT CEILING INSTALLATION: The bracket must be structurally secured within the roof, as shown on the diagram. The large round body of the ceiling bracket must protude down through the finished ceiling level by a minimum of 25mm. You must leave a 25mm clearance gap between the bracket and the ceiling.
Page 11
AURORA SUSPENDED FIRES » PITCHED CEILING INSTALLATION Custom Made For pitched ceilings we have 5 bracket sizes which your installer will adjust to achieve the exact angle for your installation. · Up to a 5 degree pitch = Flat bracket ·...
INSTALLATION INSTALLATION AND USER MANUAL LOWER FLUE LOWER FLUE LENGTHS We supply the lower flue in the standard sizes listed below. The extra length will be pushed up into the ceiling bracket, enabling you to set the correct distance from the hood to the base.
Page 13
AURORA SUSPENDED FIRES INSTALLING THE INTERNAL LOWER FLUE The lower active flue is delivered with additional length to allow for small changes to set the correct hood height. 1. First position the lower flue inside the suspension bracket 1930mm from the floor. Ensure the seam of the flue is to the back 2.
INSTALLATION INSTALLATION AND USER MANUAL HOOD INSTALLING THE HOOD 1. Once the lower active flue is secured in place lift the Hood into position and line up the bolt holes. The seam of the hood to be at the rear. 2.
AURORA SUSPENDED FIRES ZENTAI BASE The Zentai base must be secured to the floor using the circular plate and bolts provided. Ensure the base is positioned in the centre beneath the hood. Once the base is fixed to the floor, position the AB8 burner into the centre of the base and install the glass protection screen.
INSTALLATION INSTALLATION AND USER MANUAL FOR INSTALLERS CLEANING UP If the fire paint has accumulated dust, fingerprints or other residue during installation Wipe the firebox and lower flue down with a little water and a scratch free glass polishing cloth. Use a light spray of WINDEX if required. DO NOT RUB THE PAINT.
Base secured to the floor glass screen installed IMPORTANT This must be ticked and signed by the person who installs your fire and returned to aurora suspended fires following installation for any warranty claims to be honoured. NAME SIGNATURE DATE...
Page 18
Byron Bay Aurora +61 (0) 2 6686 8408 4/1 Simmons Street Ballina NSW 2478, Australia www.aurorasuspendedfires.com...
Need help?
Do you have a question about the ZENTAI and is the answer not in the manual?
Questions and answers