GARAN EWS-102 Calibration & Setup

GARAN EWS-102 Calibration & Setup

Advertisement

Quick Links

EWS-102 CONTROL UNIT
To begin the system
setup, press the
buttons together.
Enter the system setup menu.
Select the first menu item.
CAP
AL 1
AL 1
AL 2
AL 3
hyst
dLy
diSP
FIL
bEEP
5rES
Firmware 2.5 Rev 1 subje
and
CAL
SYST
CAP indicates the elevator maximum capacity. To view the current value press
AL 1 is the load value to trigger Alarm Relay 1. To view the current value press
AL 2 is the load value to trigger Alarm Relay 2. To view the current value press
AL 3 is similar to Alarms 1 & 2 but allows negative values to be entered. When editing the
most significant digit, instead of rolling over from 9 to 0 it included the minus sign option.
Defines the value by which the load in the lift has to drop to reset the instrument,
once the alarm has been triggered.
Defines the time from the control signal input is activated and the car load is stored.
Default =2, the available settings are: 0 = 0sec, 1 = 0.5sec, .....7 = 3.5sec.
Op on for turning the display on or off when the li is moving, the door close signal
ac vates. To change the setting, press
The filter value determines the update rate and damping factor. The available settings are:
0 = 0.4sec, 1 = 0.8sec, 2 = 1.2sec, 3 = 1.6sec.
An internal sounder beeps when an overload alarm is triggered or when the keypad is pressed.
To change the setting, press
Op on to turn the systems reset func on on or off. Leave OFF during system set up and zero and
load calibra on. Select ON a er calibra on and before entering the li into service.
To change the setting, press
Save and return to normal operation by pressing
a era i
The system setup menu allows you to set and adjust various
system parameters.
Naviga on
Use the
bu on to step through the menu items.
Press
to view the menu item
Edi ng Values
When a value is displayed, use
edit (selected digit flashes) and use
values for that digit.
Press
to save a change. The system will revert to the
opera onal display a er approx. 10 seconds. Alterna vely,
return to the opera onal display by pressing
Notes
To calibrate the EWS 102, a link must be fi ed to the control
signal input terminals
Un l a sensor is connected, the EWS will display Err6
preven ng access to the system setup and calibra on menus
For further informa on refer to EWS 102 User Manual
and use
To toggle between On and OFF.
and use
To toggle beteween On and OFF.
and use
To toggle beteween On and OFF.
twice
www.garan.co.uk
SYSTEM SETUP
to select the digit to
to step through the
twice
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EWS-102 and is the answer not in the manual?

Questions and answers

Summary of Contents for GARAN EWS-102

  • Page 1 EWS-102 CONTROL UNIT SYSTEM SETUP The system setup menu allows you to set and adjust various system parameters. Naviga on Use the bu on to step through the menu items. Press to view the menu item Edi ng Values When a value is displayed, use...
  • Page 2 EWS-102 CONTROL UNIT C LI R TION ERO Firmware 2.5 rev 1 subje a era i www.garan.co.uk Page 2 www.garan.co.uk...
  • Page 3 EWS-102 CONTROL UNIT C LI R TION LO Firmware 2.5 rev 1 subje a era i www.garan.co.uk Page 3 www.garan.co.uk...
  • Page 4 EWS-102 CONTROL UNIT ERROR CO ES ERR1 Sensor Signal Input Negative Reverse connection of sensor signal leads Err2 Insufficient Sensor Signal Installation Error Contact aran Err3 Sensor Offset Too igh Positive Installation Error Contact aran Err4 Sensor Offset Too igh Negative...
  • Page 5: System Setup

    EWS-102 CONTROL UNIT - MULTI ANALOG SYSTEM SETUP The system setup menu allows you to set and ad ust various system parameters. Naviga on Use the bu on to step through the menu items. Press to view the menu item...
  • Page 6 EWS-102 CONTROL UNIT - MULTI ANALOG CALI RATION ERO See Note 3: After the EWS 102 calibration and setup has been completed, place the the lift at the lowest floor level and re ero following the process on this page, this will finalise the Analog output calibration www.garan.co.uk...
  • Page 7 EWS-102 CONTROL UNIT MULTI ANALOG CALI RATION LOAD See note 3 to finalise Analog calibration www.garan.co.uk Firmware 5.5 Rev 1 s a era i Page 3 www.garan.co.uk...
  • Page 8: Error Codes

    EWS-102 CONTROL UNIT MULTI ANALOG SYSTEM SETUP Analog output Selec on There are seven selectable output ranges available. To view the current value press then use scroll through output types. Select and save required option by pressing 4-20 Output type 4-20mA.