Download Print this page

Advertisement

Quick Links

FLEX Controller
Installation and Operation Guide
ON/OFF, Dimming, DMX/COM
Configurations
www.gauzy.com • support@gauzy.com

Advertisement

loading

Summary of Contents for Gauzy LC6 FLEX Controller

  • Page 1 FLEX Controller Installation and Operation Guide ON/OFF, Dimming, DMX/COM Configurations www.gauzy.com • support@gauzy.com...
  • Page 2 Dimmer Configuration Page 10 to Page 13 ON/OFF Configuration Page 14 to Page 16 DMX/COM Configuration Page 17 to Page 24 Quick Reference Guide Page 25 to Page 27...
  • Page 3 可能会损坏该设备。 Gauzy公司对由 Connecting this device to other types of load rather than PDLC films may 于不当使用本设备而造成的任何损坏 damage the device. Gauzy Ltd. will not 不负责。 be responsible for any damaged caused by inappropriate usage of this device. 10. 如果在操作期间,闻到任何烧焦气味...
  • Page 4 PDLC PDLC peut endommager l’appareil. Gauzy puede dañar el dispositivo. Gauzy Ltd. Ltd ne sera pas responsable pour tout no será responsable de cualquier daño dégât causé...
  • Page 5 The purpose of this application note is to guide you through the process of successfully installing Gauzy’s FLEX controller. Overview Gauzy’s FLEX controller is a state of the art electronic device with many configuration options to fit in different installation scenarios. This installation manual will cover the ON/OFF, Dimming and DMX/COM functionalities.
  • Page 6 • This device was designed to control Gauzy films. Connecting this device to other types of loads rather than Gauzy films may damage the device. Gauzy Ltd. will not be responsible for any damage caused by inappropriate use of this device.
  • Page 7 Pinout HV CNTL POWER IN Note: Some features may be available only on specific models. Refer to the table on the following page.
  • Page 8: Table Of Contents

    AC Mains & High Voltage Control Terminal Terminal Description Name Number Ground AC mains input. Connect to the input 110/220 VAC Ground. Neutral AC mains input. Connect to the input 110/220 VAC Neutral. Line AC mains input. Connect to the input 110/220 VAC Line. High voltage dimmer up / ON-OFF.
  • Page 9 RS485/DMX/COM Control (available on specific models) Terminal Terminal Description Name Number DMX input connector / RS485 interface. DMX - D-Type When installed in a DMX system this is the input connector in Pin 2 the DMX chain. When installed in a DMX system this is the output connector DMX - D-Type in the DMX chain and should be connected to the next device...
  • Page 10: Ground

    DIMMER FLEX Dimming Controller is a state of the art electronic Gauzy’s smart appliance that allows dimming of Gauzy films. This manual covers the installation of the FLEX Dimming Controller. The Dimming functionality of the controller can be achieved in two different ways: •...
  • Page 11: Line

    AC LINE through relays. DOWN Line 110/220VAC Note: Do not close simultaneously more than one dry contact. Operation under this condition is not guaranteed. Note: You can also use Gauzy’s Controller Dimming Touch Panel for this configuration. Gauzy Dimming Touch Panel Dimmer...
  • Page 12 Dry Contact Dimmer Control Ground AC mains Neutral LINE 110/220VAC 32 HZ LINE/2 Film Out Line Film COMMON OUT OK ALARM COMMON COMMON MUTE COMMON DT/ON-OFF Dimmer Wall Switch Before proceeding make sure the main AC voltage is disconnected. Any electrical connection should be done by a qualified electrician.
  • Page 13: Mute

    MUTE Contact Contact Frequency Switching Gauzy’s controllers have the capability to adjust the operating frequency of the system to adapt itself and prevent flickering effects under certain lighting conditions. In addition to that, the lower the frequency used, the less power is consumed by the system.
  • Page 14 ON/OFF FLEX ON/OFF Controller is a state of the art electronic Gauzy’s Smart appliance that allows Gauzy films to turn on and off. This manual covers the installation of the FLEX ON/OFF Controller. The ON/OFF functionality of the controller can be achieved in two different ways: •...
  • Page 15 The same functionality can be achieved by connecting the ON/OFF Line terminal to the AC LINE through a relay. 110/220VAC ON/OFF Note: You can also use Gauzy’s ON/OFF Touch Panel for this configuration. Gauzy ON/OFF Dry Contact Control Interface Touch Panel Ground AC mains...
  • Page 16 The same functionality can be achieved by connecting terminals DT- ON/OFF & COMMON through a regular ON/OFF wall switch as shown in the picture above. Frequency Switching Gauzy’s controllers have the capability to adjust the operating frequency of the system to adapt itself and prevent flickering effects under certain lighting conditions.
  • Page 17 The DMX/COM functionality of the controller can be achieved in three different ways: • ON/OFF control - allows Gauzy and films to turn on and off. • DIMMER control - allows dimming of Gauzy and films. • OPEN INTERFACE control...
  • Page 18 Configuring the Flex for DMX/COM Operating Mode The Flex can work in one of the two modes: (1) DMX or (2) COM API using RS- 485 link. The selection and configuration between these two modes is done via a HyperTerminal. In order to configure the desired working mode, execute the following steps: Connect AC mains to the LINE, NEUTRAL and GROUND terminals respectively.
  • Page 19 Configure the Flex controller according to the description below: Command Syntax Command Description Examples Name Sets the DMX base A<decimal, 3 Set DMX ID address designated A001 A009 digits> to the controller. Returns the DMX Get DMX ID base address of the 001 009 controller.
  • Page 20 DMX-512 Working with the DMX Interface The Flex controller has 1 channel output. Each data is composed of an 8-bit word that refers the status of the Flex controller output. DMX protocol allowing to chain a total of 512 Flex controllers to reside in one DMX512 link (Universe).
  • Page 21 When having more than one Flex controller connected to the same DMX link, addressing must be done in such a way to avoid overlapping of the channels in the controllers: The following table shows an example for a DMX link with 4 Flex controllers: DMX ID Flex Controller Data Values...
  • Page 22 The following values should be sent to the specific DMX address ID, in order to control the On-Off: • Turns Off (Opaque): (Bin): 00000000 = (Hex): 0x00 • Turns On (Transparent): (Bin): 00000001 = (Hex): 0x01 Dimmer: • Stops the dimming output level at the moment you sent the command: (Bin): 00000000 = (Hex): 0x00 •...
  • Page 23 Configuring the Flex for COM Operating Mode In COM mode, only a single controller can be connected to the link, thus this is a point to point connection and not a daisy chain like the DMX protocol. When used in COM mode, the Flex can be accessed from a PC with a simple API using a RS-485 link.
  • Page 24 A simple command is defined to control of the output channel value: H <channel status> For example: On-Off: • H0 - Turns Off (Opaque): the output channel • H1 - Turns On (Transparent): the output channel Dimmer: • H0 - Stops the dimming output level at the moment you sent the command •...
  • Page 25 Quick Reference Guide Basic Wiring Diagram - On/Off...
  • Page 26 Basic Wiring Diagram - Dimmer...
  • Page 27 Basic Wiring Diagram - DMX...
  • Page 28 TN 09-12.01 www.gauzy.com • support@gauzy.com...