  • Page 1 H205 H225 P100 P115 P100 P115 L125 L250 L375 ISA S.r.l. Division TASSELLI Via del Lavoro, 5 06083 Bastia Umbra - Perugia - Italy Tel. +39 075 80171 - Fax +39 075 8000900 www.isaitaly.com PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 2: Table Of Contents

    NOTES / IMPORTANT NOTES INTRODUCTION MANUFACTURER’S CONTACT DETAILS SAFETY STAFF TRAINING SAFETY DEVICES APPLIED 2.2.1 SAFETY DEVICES PRESENT 2.2.2 FIXED GUARDS 2.2.3 ISOLATING THE ELECTRICTY SUPPLY RESIDUAL RISKS 2.3.1 RISK OF CONTACT WITH LIVE PARTS 2.3.2 FIRE 2.3.3 EXPLOSIVE ATMOSPHERE 2.3.4 SLIPPING 2.3.5...
  • Page 3 Attachment 1 DECLARATION OF CONFORMITY Attachment 2 DISCHARGE Attachment 3 DUCTING Attachment 4 BRACKETS Attachment 5 SIDE ASSEMBLY Attachment 6 UNPACKING AND HANDLING Attachment 7 BRACKETS Attachment 8 MIRROR Attachment 9 BASE BOARDS Attachment 10 CHANGE IN SHELVES Attachment 11 HOOKS Attachment 12 SPACER REAR...
  • Page 4: Notes / Important Notes

    If lost or destroyed, you can request a copy of the manual from ISA S.r.l. division TASSELLI by specifying the exact model, serial number and year of manufacture. The manual refl ects the manufacturing technology at the time of supply.
  • Page 5: Introduction

    1.1 Introduction ISA S.r.l. division TASSELLI employs materials of the best quality and as they enter the company, we constantly monitor their storage and the use as part of the manufacturing process to prevent damage, deterioration and failure. All manufacturing elements are designed and manufactured in order to guarantee reliability and high safety standards.
  • Page 6: Safety

    2. SAFETY The buyer is responsible for training personnel using the appliance on the risks, safety devices and general health and safety rules required by the laws of the country where the appliance is installed. Users/operators should be aware of the position of all the controls and how they work, as well as of the features of the appliance.
  • Page 7: Isolating The Electricty Supply

    2.2.3 Isolating the electricity supply Before conducting any maintenance work on the equipment or part of it, it is necessary to section the power supply that powers it Danger Therefore remember, in the event of maintenance operations in which the operator cannot prevent accidental closure of the circuit by others, to totally disconnect the appliance from the mains electricity.
  • Page 8: Explosive Atmosphere

    2.3.3 Explosive atmosphere The equipment must not be located in an area classifi ed as an explosion risk according to 1999/92/EC such as: Zone 0 An area in which there is a permanent, long-lasting or frequently explosive atmosphere made up of a mixture of air and fl ammable substances in the form of gases, fumes or steam. Zone 1 An area in which the formation of an explosive atmosphere, made up of a mixture of air and fl...
  • Page 9: Foodstuffs Safety

    2.3.9 Foodstuffs safety The refrigerator cabinet described herein is meant to be used to display packaged products. As such, it is not designed for direct contact between the foodstuffs and display surfaces. If the foodstuffs do accidentally make contact with the surfaces and for a rather long time, the product may be contaminated.
  • Page 10: Disposal Of Waste Material

    3. DISPOSAL OF WASTE MATERIAL During normal operation, the appliance does not generate any environmental contamination. At the end of its life cycle, or if it is necessary to proceed to permanent decommissioning, we recommend following the procedures below: DISPOSAL (User) The symbol, applied to either the product or its packaging, indicates that the product should not be considered as normal domestic waste, but should be taken to a waste collection point for the recycling of electrical and electronic appliances.
  • Page 11: Installation

    4. INSTALLATION This manual supplies the information necessary for correct unpacking, procedures for positioning and connection to mains electricity. 4.1 Storage and unpacking The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas away from the elements and direct sunlight, at a temperature between 00 and +40 °C.
  • Page 12: Technical Specifications

    5. TECHNICAL SPECIFICATIONS This appliance is exclusively intended to display and sell cheeses, milk products and/or fresh pre-packed products. The manufacturer is not liable for injury to persons or damage to property or the appliance itself caused by the displaying of products other than those described above. Uses not allowed: - Food preservation.
  • Page 13 5. TECHNICAL SPECIFICATINS PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 14: Installation And Levellig

    5.1 Installation and Levelling The installation of the apparatus involves the formation of channels as that described in fi gure, typically consisting of one or more counters and from the shoulders of the ends. If the channel were to be installed against walls, the minimum distances of: •...
  • Page 15: Technical Plan - Air Cooled

    5.2 Technical plan - AIR cooled P100 P115 1000 mm 1145 mm 1100 mm 1245 mm 795.5 mm 940.5 mm Cabinet feet 32 mm Drain pipe Ø 40 mm Terminal box Control board Standard endwall (optional) PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 16: Technical Plan - Water Cooled

    5.2 Technical plan - WATER cooled P100 P115 1000 mm 1145 mm 795.5 mm 940.5 mm Cabinet feet 32 mm Drain pipe Ø 40 mm Terminal box Control board Standard endwall (optional) H20 IN / H20 OUT 1/2” F Piping H20 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 17: Load Limits

    5.3 Load limits Attention It is fundamental not to exceed the load limits indicated in order not to alter the correct air circulation and thus prevent a high product temperature. The limits indicated refer to a static and evenly distributed load. Therefore dynamic overloads due to violent loading operations are excluded, which must be prevented foe safety reasons.
  • Page 18: Connecting The Water Line (Water Cooled)

    5.5 Connecting the water line (water cooled) If provided in the condensation water, the device provides for the connection to an external line with water at Pmax <4 bar. The following table shows the data required for the sizing of the line and the external cooling system. Panda water cooled condensation version chilled water...
  • Page 19: Description Of The Appliance

    6. DESCRIPTION OF THE APPLIANCE To ensure the operator's safety, appliance devices should be kept in constant working order. Regarding this, the manual has the purpose of illustrating use and maintenance of the appliance and the operator has the responsibility and the duty to respect it scrupulously. 6.1 Composition Once the appliance is installed, it is an integral part of the electric plant, a cooling plant and a hydraulic plant and can be schematized according to the following layout.
  • Page 20: Identification

    6.3 Identifi cation Symbols of Compliance Identifi cation of the Company Product Manager Production Order Type Model Name Article Serial Number Production Date 9 - 10 Power supply - Voltage and Frequency Gross Capacity Absorption at Rated Capacity Absorption during Defrosting Absorption of Heating Elements Lamp Power Fuse Value...
  • Page 21: Control Panel

    7. CONTROL PANEL Switch-on/off lights on the counter Key lights Optional. In the control panels with CAREL controller, and ELIWELL DIXELL the button lights are integrated in the keys of the same units. The counter subject of this manual, can be fi tted with an electronic command and supervision unit which, even being an integral part of the appliance, is provided with a separate manual to be consulted for all details.
  • Page 22: Cleaning

    8. CLEANING 8.1 Inside the cabinet a) Remove the product contained in the cabinet and put it immediately in a relevant cold storage container in order to guarantee correct preservation. b) Switch the appliance off. Wait at least 4 to 6 hours, until the ice on the evaporator has melted completely, before proceeding with cleaning operations.
  • Page 23: Maintenance

    9. MAINTENANCE The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table below, calling the authorised Technical After-sales assistance when indicated. OPERATION FREQUENCY AUTHORISED PERSONNEL CLEANING THE EXTERNAL SURFACES CLEANING THE ACCESSIBLE INTERNAL PARTS (without the use of tools) CONTROL POWER SUPPLY CABLE, USER...
  • Page 24: Faults - Technical After Sales Assistance

    10. FAULTS - TECHNICAL AFTER-SALES ASSISTANCE If the appliance is not working properly or stops working, before contacting the Customer support centre, check the following: FAULT CAUSE SOLUTION AUTHORISED PERSONNEL THE APPLI- Blown protective fuse Previously fi nd the cause of the intervention USER ANCE IS of the switch, and then re-introduce the new fuse.
  • Page 25: Warranty Terms And Conditions

    11. WARRANTY TERMS AND CONDITIONS The seller's warranty on the equipment is valid for 12 (TWELVE) months from the date of delivery. The warranty includes repairs or replacements of any faulty parts due to manufacturing processes or installation after written communication has been received, stating the appliance serial number and date of installation.
  • Page 26 Attachment 1 - DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY We: ISA S.r.l. Via del Lavoro, 5 - 06083 - Bastia Umbra (PG) declare under our own responsibility, that the product: PANDA Product: Serial number: ..To which this declaration refers, is in compliance with e following: MACHINERY SAFETY General electric safety Standard EN 60335-1/Ed.2002+Modifi...
  • Page 27 Attachment 2 - DISCHARGE Discharge Ø 40 mm Braga - Z max: 45° Ø 40 mm Quick connections pipes Ø 40 mm Curved tube 45° Ø 40 mm PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 28 Attachment 3 - DUCTING • Screw M8x35 (rif. W9211186) • Nut M8 (rif. W9215124) • Washer Ø 8 (rif. 50030002501) • Screw M8x150 (rif. W9211131) • Nut M8 (rif. W9215124) • Washer Ø 8 (rif. 50030002501) Connecting plug - Quantity 2 Sponge tape 10x10 mm PANDA USE AND MAINTENANCE MANUAL...
  • Page 29 Attachment 4 - BRACKETS PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 30 Attachment 5 - SIDE ASSEMBLY • Screw M6x30 (rif. 50010804709) • Screw A-FOR M5x70 (rif. W9211983) • Nut M8 (rif. W9215124) • Washer Ø 8 (rif. 50030002501) Bolts included frame doors Sponge tape 10x10 mm PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 31 Attachment 6 - UNPACKING AND HANDLING PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 32 Attachment 7 - BRACKETS PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 33 Attachment 8 - MIRROR PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 34 Attachment 9- BASE BOARDS PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 35 Attachment 10 - CHANGE IN SHELVES PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 36 Attachment 11 - HOOKS PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 37 Attachment 12 - SPACERS REAR PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 38 Attachment 13 - WIRING DIAGRAM - 412100606200 - Sheet 1 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 39 Attachment 13 - WIRING DIAGRAM - 412100606200 - Sheet 2 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 40 Attachment 13 - WIRING DIAGRAM - 412100606200 - Sheet 3 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 41 Attachment 14 - WIRING DIAGRAM - 412100607200 - Sheet 1 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 42 Attachment 14 - WIRING DIAGRAM - 412100607200 - Sheet 2 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 43 Attachment 14 - WIRING DIAGRAM - 412100607200 - Sheet 3 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 44 Attachment 15 - WIRING DIAGRAM - 412100608100 - Sheet 1 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 45 Attachment 15 - WIRING DIAGRAM - 412100608100 - Sheet 2 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 46 Attachment 15 - WIRING DIAGRAM - 412100608100 - Sheet 3 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 47 Attachment 16 - WIRING DIAGRAM - 412100609100 - Sheet 1 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 48 Attachment 16 - WIRING DIAGRAM - 412100609100 - Sheet 2 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 49 Attachment 16 - WIRING DIAGRAM - 412100609100 - Sheet 3 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 50 Attachment 17 - WIRING DIAGRAM - 412100615100 - Sheet 1 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 51 Attachment 17 - WIRING DIAGRAM - 412100615100 - Sheet 2 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 52 Attachment 17 - WIRING DIAGRAM - 412100615100 - Sheet 3 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 53 Attachment 18 - WIRING DIAGRAM - 412100616000 - Sheet 1 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 54 Attachment 18 - WIRING DIAGRAM - 412100616000 - Sheet 2 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 55 Attachment 18 - WIRING DIAGRAM - 412100616000 - Sheet 3 of 3 PANDA USE AND MAINTENANCE MANUAL 428900224237...
  • Page 56 Attachment 19 - CONTROL PANEL - IR33 - Sheet 1 of 2 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. PRESSURE PRESSURE SINGLE KEY COMBINED WITH OTHER KEYS •...
  • Page 57 Attachment 19 - CONTROL PANEL - IR33 - Sheet 2 of 2 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. ICONA FUNCTION FLASHING START-UP COMPRESSOR...
  • Page 58 Attachment 20 - CONTROL PANEL - AK CC 250 - Sheet 1 of 1 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. KEYS Down for 5 seconds to enter the programming.
  • Page 59 Attachment 21 - CONTROL PANEL - EW 978 - Sheet 1 of 3 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. At start-up, the instrument conducts a LAMP TEST for a few seconds.
  • Page 60 Attachment 21 - CONTROL PANEL - EW 978 - Sheet 2 of 3 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. At start-up, the instrument conducts a LAMP TEST for a few seconds.
  • Page 61 Attachment 21 - CONTROL PANEL - EW 978 - Sheet 3 of 3 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. At start-up, the instrument conducts a LAMP TEST for a few seconds.
  • Page 62 Attachment 22 - CONTROL PANEL - XR 44 CX - Sheet 1 of 2 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. KEYS SINGLE PRESS COMBINED PRESSION...
  • Page 63 Attachment 22 - CONTROL PANEL - XR 44 CX - Sheet 2 of 2 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. ICONA FUNZIONE LAMPEGGIANTE...
  • Page 64 Attachment 23 - CONTROL PANEL - CRD XP - Sheet 1 of 3 Attention The electronic control board is installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. KEY PARAMETER FORWARD KEY BACK BUTTON DEFROSTING LED...
  • Page 65 Attachment 23 - CONTROL PANEL - CRD XP - Sheet 2 of 3 BASIC SETTINGS (parameters P00-P09) Procedure Description Result Display number Press and hold the 1 key. The display shows the number parameter. of display. Display number Press and hold the 1 key Press the 2 key.
  • Page 66 Attachment 23 - CONTROL PANEL - CRD XP - Sheet 3 of 3 ALARM SIGNIFICATION PERSONNEL AUTHORIZED Sensor fault F1. In the case of adjusting the supply air: Operation di’emergenza. In the case of weighted adjustment: Determining the actual value adjustment only with F2. Sensor fault F1 and F2.