CHINSC ELECTRIC 200 Series Operation Manual

General purpose vector ac drive
Table of Contents

Advertisement

200 Series General Purpose Vector AC Drive
Operation Manual
Material Version
: V3.4
Date of Filing
: 2021-04-14
Company Standard
: Q/903703SSC002-2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for CHINSC ELECTRIC 200 Series

  • Page 1 200 Series General Purpose Vector AC Drive Operation Manual Material Version : V3.4 Date of Filing : 2021-04-14 Company Standard : Q/903703SSC002-2019...
  • Page 2: Table Of Contents

    200 Series General Purpose Vector AC Drive Contents Contents Chapter 1 Safety and Notes ..................... 1   1.1 Safety Notes ......................1   1.2 Notes ........................1   Chapter 2 Specifications and Selection ................3   2.1 Naming Rules ......................3  ...
  • Page 3 Contents 200 Series General Purpose Vector AC Drive Chapter 5 Function Parameter Simple List ..............33   Chapter 6 Key Function Parameter Explanation In Detail ..........58   Chapter 7 Communication Protocol ................68   7.1 Communication Allocation ..................68   7.2 Salve Machine Address ..................68  ...
  • Page 4: Chapter 1 Safety And Notes

    200 Series General Purpose Vector AC Drive Chapter 1 Safety and Notes Chapter 1 Safety and Notes 1.1 Safety Notes 1. The AC drive should be installed and adjusted by professional electrical technicians, otherwise there is a danger of electric shock! 2.
  • Page 5 Chapter 1 Safety and Notes 200 Series General Purpose Vector AC Drive The electrolytic capacitor of the main circuit and the electrolytic capacitor on the printed board may explode during incineration. The incineration of plastic will produce poisonous gas, please deal with it as industrial waste.
  • Page 6: Chapter 2 Specifications And Selection

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection Chapter 2 Specifications and Selection 2.1 Naming Rules 200 - G 15 P 18.5 T4 B/Z/F-ET - N/2N/A 200:General purpose vector ac drive Upgraded version 230-QM:Ball mill special purpose...
  • Page 7 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 200-G3.7/P5.5T4B-N 10.5 9/13 3.7/5.5 200-G5.5/P7.5T4B-2N 14.6 13/17 5.5/7.5 200-G7.5/P11T4B-2N 11.0 20.5 17/25 7.5/11 200-G11/P15T4B-N 17.0 26.0 25/32 11/15 200-G15/P18.5T4B-N 21.0 35.0 32/37 15/18.5 200-G18.5/P22T4B-N 24.0 38.5 37/45 18.5/22 200-G22/P30T4B-2N 30.0...
  • Page 8 200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 230-QM55T4/Z-ET-A 85.0 113.0 230-QM55T4/F-ET-A 230-QM75T4/F-ET-A 114.0 157.0 230-QM93T4/F-ET-A 134.0 180.0 230-QM110T4/F-ET-A 160.0 214.0 230-QM132T4/F-ET-A 192.0 256.0 230-QM160T4/F-ET-A 231.0 307.0 230-QM185T4/F-ET-A 242.0 350.0 230-QM200T4/F-ET-A 250.0 385.0 230-QM220T4/F-ET-A 280.0 430.0 230-QM250T4/F-ET-A 355.0...
  • Page 9 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 260-KH280T4-2N 396.0 525.0 260-KH315T4-2N 445.0 590.0 260-KH350T4-2N 500.0 665.0 260-KH400T4-A 565.0 785.0 260-KH450T4-A 650.0 825.0 260-KH500T4-A 700.0 883.0 260-KH550T4-A 770.0 975.0 260-KH630T4-2N 1000.0 1400.0 1100 260-KH700T4-2N 1200.0 1450.0 1300...
  • Page 10 200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 280 Model and technical parameters Input Current Output Adaptive Power Capacity VFD Model Input V Current A Motor KW 280-FB7.5T4B-X 11.0 20.5 280-FB11T4B-X 17.0 26.0 280-FB15T4B-X 21.0 35.0 280-FB18.5T4B-X 24.0...
  • Page 11: Technical Specification

    Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 2.4 Technical specification Item Specification Rated voltage T4 series: 3 phase 380V, ±15% Frequency 50/60Hz ±5% T4 series : 3 phase 0~380V Voltage 0~3000Hz Frequency G Type: 150% rated current for 1 minute, 180% rated current for 3 seconds;...
  • Page 12: 200-N Product Outline And Installation Aperture Size

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 2.5 200-N Product Outline and Installation Aperture Size 2.5.1 200-N G0.4~G18.5KW Outline and Outer Size of Hang Machine Plastic Casing AC Drive Weight Installation VFD Model (Kg) aperture 200-G0.4T4B-N 200-G0.75T4B-N...
  • Page 13: 200-N G22~G550Kw Outline And Outer Size Of Hang Machine Metal Casing Ac Drive

    Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 2.5.2 200-N G22~G550KW Outline and Outer Size of Hang Machine Metal Casing AC Drive Installation Weight VFD Model (Kg) aperture 200-G22/P30T4B-2N 200-G30/P37T4B-2N Φ7 200-G37/P45T4-2N 200-G45/P55T4-N Φ8 200-G55/P75T4-N 200-G75/P93T4-N 200-G93/P110T4-N Φ10...
  • Page 14: 230 Series Ball Mill Special Purpose Ac Drive Product Outline Drawing And Installation Hole Size

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 2.6 230 Series Ball Mill Special Purpose AC Drive Product Outline Drawing and Installation Hole Size Rings Dashboard Cover base Lower door panel Rear door panel...
  • Page 15 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive Weight Installation VFD Model (Kg) aperture 230-QM22T4B/Z-ET-A 230-QM30T4B/Z-ET-A Φ10 230-QM37T4/Z-ET-A 230-QM45T4/Z-ET-A 230-QM45T4/F-ET-A Φ12 230-QM55T4/Z-ET-A 230-QM55T4/F-ET-A 230-QM75T4/F-ET-A 230-QM93T4/F-ET-A 1000 Φ14 230-QM110T4/F-ET-A 230-QM132T4/F-ET-A 230-QM160T4/F-ET-A 230-QM185T4/F-ET-A 1400 Φ14 230-QM200T4/F-ET-A 230-QM220T4/F-ET-A 230-QM250T4/F-ET-A 230-QM280T4/F-ET-A 1600 Φ14...
  • Page 16: 260 Series Engineering Type Vector Ac Drive Product Outline Drawing And Installation Hole Size

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 2.7 260 Series Engineering Type Vector AC Drive Product Outline Drawing and Installation Hole Size Rings Dashboard Cover base Lower door panel Rear door panel...
  • Page 17 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive Installation Weight VFD Model aperture (Kg) 260-KH30T4B-A 260-KH37T4B-A Φ10 260-KH45T4-A 260-KH55T4-2N Φ12 260-KH75T4-2N 260-KH93T4-2N 260-KH110T4-2N 1000 Φ14 260-KH132T4-2N 260-KH160T4-2N 260-KH185T4-2N 260-KH200T4-2N 1400 Φ14 260-KH220T4-2N 260-KH250T4-2N 260-KH280T4-2N 260-KH315T4-2N 1600 Φ14...
  • Page 18: 270 Series Movable Crusher Special Purpose Ac Drive Product Outline Drawing And Installation Hole Size

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 2.8 270 Series Movable crusher Special Purpose AC Drive Product Outline Drawing and Installation Hole Size 2.8.1 270 Series 11~18.5KW Outline and Outer Size of Hang Machine Plastic Casing...
  • Page 19: 270 Series 132~400Kw Outline And Outer Size Of Hang Machine Metal Casing Ac Drive

    Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive Installation Weight VFD Model aperture (Kg) 270-PS22T4B 270-PS30T4 Φ7 270-PS37T4 270-PS45T4 Φ8 270-PS55T4 270-PS75T4 270-PS93T4 Φ10 270-PS110T4 2.8.3 270 Series 132~400KW Outline and Outer Size of Hang Machine Metal Casing...
  • Page 20: 280 Series Factory Explosion-Proof Ac Drive Movement Product Outline

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection Installation Weight Model VFD aperture (Kg) 270-PS132T4 67+200*3 217+217 Ø12 270-PS160T4 270-PS185T4 270-P200T4 77+200*2 102+200*3 270-PS220T4 Φ12 +102 270-PS250T4 270-PS280T4 270-PS315T4 204.5+200* 127+200*3 270-PS350T4 1055 450 Φ14 +127 +204.5 270-PS400T4 2.9 280 Series Factory Explosion-proof AC Drive Movement Product Outline...
  • Page 21 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 22~37KW AC drive outline drawing and outline size diagram...
  • Page 22 200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 45~75KW AC drive outline drawing and outline size diagram...
  • Page 23 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 93~110KW AC drive outline drawing and outline size diagram...
  • Page 24 200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 132~185KW AC drive outline drawing and outline size diagram...
  • Page 25 Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 200~280KW AC drive outline drawing and outline size diagram Installation Weight VFD Model aperture (Kg) 280-FB7.5T4B-X 280-FB11T4B-X Φ9.5 22.5 280-FB15T4B-X 280-FB18.5T4B-X 280-FB22T4B-X 280-FB30T4B-X Φ9.5 280-FB37T4-X 280-FB45T4-X 353.5 Φ9.5...
  • Page 26: Keyboard Outline Size

    200 Series General Purpose Vector AC Drive Chapter2 Specifications and Selection 280-FB55T4-X 280-FB75T4-X 280-FB93T4-X Φ9.5 280-FB110T4-X 280-FB132T4-X 280-FB160T4-X 347.5 Φ11.5 280-FB185T4-X 280-FB200T4-X 280-FB220T4-X Φ11.5 280-FB250T4-X 280-FB280T4-X 2.10 Keyboard Outline Size 1、Keyboard Outline Size(mm) 23,3 2-M3 2、Keyboard Back Fixed Opening Size Without Keyboard Tray(mm) 3、Keyboard Tray Outline Size...
  • Page 27: The Disassembly And Installation Of The Keyboard

    Chapter2 Specifications and Selection 200 Series General Purpose Vector AC Drive 17.5 Keyboard Tray Outline Size Keyboard Tray Open Size 2.11 The Disassembly and Installation of the Keyboard Disassembly the Keyboard: According to the indication of Figure 1,please press the operation panel clip down with the index finger, then put up the operation panel as the direction of the Figure 2.
  • Page 28: Chapter 3 Mechanical And Electrical Installation

    200 Series General Purpose Vector AC Drive Chapter 3 Mechanical and Electrical Installation Chapter 3 Mechanical and Electrical Installation 3.1 External Electrical Components Selection Guide Recommended Recommended Recommended Recommended Power Air Switch Input Side Main Output Side Main Contactor Control Circuit...
  • Page 29: Main Circuit Terminal And Wiring

    Chapter 3 Mechanical and Electrical Installation 200 Series General Purpose Vector AC Drive 3.2 Main Circuit Terminal and Wiring Braking unit DC reactor Braking resistor Input power supply MCCB Motor AC Driver and motor earthing 485+ Motor casing 485- Relay output:...
  • Page 30 200 Series General Purpose Vector AC Drive Chapter 3 Mechanical and Electrical Installation External reactor wiring G132KWand bigger power, the add external reactor connect P、(+) terminals outside point. The AC Drive output U、V、W Connect 3-phase motor terminals Grounding terminal Grounding terminal 2、Main control circuit terminals drawing...
  • Page 31 Chapter 3 Mechanical and Electrical Installation 200 Series General Purpose Vector AC Drive Output voltage or current could be selected by the JP9 jumper of the control board. FM1—GND Analog output 1 Output voltage range: DC 0V~10V; Output current range: DC 0~20mA.
  • Page 32 200 Series General Purpose Vector AC Drive Chapter 3 Mechanical and Electrical Installation JP9: JP19 JP2 JP19: JP2: 485- 485+...
  • Page 33: Chapter 4 Keyboard Operation And Display

    Chapter 4 Keyboard Operation and Display 200 Series General Purpose Vector AC Drive Chapter 4 Keyboard Operation and Display 4.1 Introduction Of Keyboard Operation and Display Interface Through the keyboard operation panel, we could modify the functional parameter to the AC Drive, monitor the working condition and perform the operational control (start, stop) of AC Drive, its outline and functional zone are as follows.
  • Page 34: Descriptions Of Function Indicators

    200 Series General Purpose Vector AC Drive Chapter 4 Keyboard Operation and Display 4.2 Descriptions of Function Indicators RUN: When light off, the ac drive is in stop status, when light on, the drive is in running status. REMOT: Keyboard operation, terminal operation and remote operations (communication control)
  • Page 35 Chapter 4 Keyboard Operation and Display 200 Series General Purpose Vector AC Drive In the second level menu state, if the parameter is without flash bit, it indicates that the function code couldn’t be modified, it may be caused by the following reasons: 1) The function code is non-modifiable parameters, such as actual monitoring parameters and run recording parameters and so on.
  • Page 36: Chapter 5 Function Parameter Simple List

    Chapter 5 Functional Parameter Simple List Chapter 5 Function Parameter Simple List The function parameters of 200 series AC Drive are organized in groups by functions. And there are 16 groups from F0-FF. Each function group consists of several function codes that are identified by “Function Group No.
  • Page 37 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive direction is decided by main frequency) 4: Main frequency - auxiliary frequency ( the direction is decided by main frequency) 5: The maximum of both the direction is...
  • Page 38 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List rotation, three-wire terminal is normally open, and stops when closed. Motor control mode 0: No PG speed vector control(needs to set F3 (it needs to set F0-14=0、...
  • Page 39 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive 2: Standby state (without output voltage) 0.00~5.00Hz( Free stop after deceleration to Minimum frequency of F0-25 0.00Hz √ deceleration to stop this value) 1: 0.1Hz 2: 0.01Hz...
  • Page 40 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List selection 0: Protection(The terminal is closed before power-on and operation is not allowed) 1: No protection(The terminal is closed before power-on to allow operation) 0.00~10.00Hz F1-01 Directly start frequency 0.00Hz...
  • Page 41 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive 0: Disabled 1: Enabled Hundred units: Carrier adjustment associated frequency 0: Disabled 1: Enabled Automatic reset 0: Disable F1-16 √ operation enable 1: Enable Start frequency 0.01s~320.00s F1-17 0.01s...
  • Page 42 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List point 2 Multi-point VF voltage 0.0%~100.0% F2-06 45.0% √* point 2 Multipoint VF frequency 0.00~F0-05 F2-07 35.00Hz √* point 3 Multi-point VF voltage 0.0%~100.0% F2-08 80.0% √*...
  • Page 43 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive 0.001Ω~32.000Ω(ac drive power<=55kW) Tuning F3-04 Motor resistance of rotor ×* 0.0001Ω~3.2000Ω(ac drive power>55kW) parameters 0.01mH~320.00mH(ac drive power<=55kW) Leakage inductance of Tuning F3-05 ×* 0.001mH~32.000mH(ac drive power>55kW) stator and rotor parameters 0.1mH~3200.0mH(ac drive power<=55kW)
  • Page 44 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List 1: Upper limit frequency set by analogue V1 2: Upper limit frequency set by analogue V2 Generator torque digit 50.0~300.0% F3-20 setting ( rotation speed 140.0% √...
  • Page 45 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive selection 09: Frequency setting increment (UP) 10: Frequency setting decreasing(DOWN) 11: Frequency increase/decrease (UP/DOWN) setting clear 12: Multi-speed terminal 1 13: Multi-speed terminal 2 14: Multi-speed terminal 3...
  • Page 46 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List 0~20(When the PID pressure is unstable, F4-15 V1 input filter factor increase appropriately; when the specified input √ requires quick response, decrease appropriately) 0.00~F4-18 F4-16 V2 lower limit value 0.10V...
  • Page 47 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive (Need to connect IO 06: Zero-speed running(no output in stop) expansion card) 07: Frequency upper limit arriving (≥F0-06 output) F5-04 Reserved 08: Frequency lower limit arriving (≤F0-07...
  • Page 48 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List FDT lag detection value 000.0%~100.0%(FDT Electric Level) F5-15 5.0% √* 0.0%~250.0% F5-16 FDT torque level value 100.0% √ FDT torque level 0.0%~100.0%(FDT Electric Level) F5-17 5.0% √...
  • Page 49 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive FM2 upper limit 0.00~10.00V F5-28 10.00V √ corresponding output HDO high-speed pulse 0.0~100.0% F5-29 0.00% √ output lower limit HDO low limit 0.00kH 0.00~100.00kHz F5-30 √ corresponds output HDO high speed pulse 0.0~100.0%...
  • Page 50 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List Multi-speed 8 target PLC phase 9/ -100.0~100.0% F6-09 0.0% √ Multi-speed 9 target PLC phase 10/ -100.0~100.0% F6-10 0.0% √ Multi-speed 10 target PLC phase 11/ -100.0~100.0% F6-11 0.0%...
  • Page 51 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive time PLC phase 14 operation 0.0~3200.0s F6-30 0.0s √ time PLC phase 15 operation 0.0~3200.0s F6-31 0.0s √ time Unit: Cycle mode selection 0: Stop after operating for 1 cycle...
  • Page 52 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List (F7-08) 2: Faulty stop(E022) Tens: Feedback over-voltage protect selection 0: Invalid 1: Alarm and operation in settled frequency (F7-15) 2: Faulty stop(E024) 0.0~100.0%(100.0% Corresponding pressure gauge range) If the pressure gauge is 1.6MPA and the target...
  • Page 53 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive percentage When the feedback pressure is lower than (pressure setting value * F7-11), the wake-up timer is performed. if the wake-up timer exceeds the wake-up delay time of F7-12, the ac drive exits the dormant state.
  • Page 54 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List The unit : MF.K key function selection 0: Jog forward operation 1: Switch between forward and reverse 2: Clear UP/DOWN set 3: Main and auxiliary frequency source switch...
  • Page 55 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive 25: Communication set value 26: Module temperature 27: Accumulated power-on time H 28: PLC Elapsed time 29: PLC remaining time 30: PLC Total set time 31: Cumulative power consumption KW...
  • Page 56 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List Adjust V1 to set the main frequency within the range of F0-30~F0-31 Line 2 normal FA-14 monitoring parameter The same as F9-01 selection √ selection Peed tracking DC 10~200%...
  • Page 57 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive Hundred: Input phase loss protection 0: Invalid 1: Valid Thousands : Output loss-Phase protection 0: Invalid 1: Valid Continuous failure rest 1.0~600.0s Fb-01 30.0s √ time Motor overload 20.0~125.0%(motor rated current)
  • Page 58 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List E018: Communication over time fault E019: Current detection t fault E020: Motor’s parameter auto-learning fault E021: EEPROM w/r error E022: PID feedback disconnected fault E023: Too large AD zero drift...
  • Page 59 Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive decrease frequency level During operation, if the output current exceeds the software frequency reduction and current limit level when the load is overloaded, the drive output frequency will be reduced according to Fb-05.
  • Page 60 200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List FF-22 Present PLC stage ○ FF-23 Input terminal decimal ○ FF-24 Output terminal decimal ○ FF-25 Communication set value ○ FF-26 IGBT temperature 0.1℃ ○ ℃ FF-27 Cumulative running time H ○...
  • Page 61: Chapter 6 Key Function Parameter Explanation In Detail

    Chapter 6 Key Functional Parameter Explanation In Detail 200 Series General Purpose Vector AC Drive Chapter 6 Key Function Parameter Explanation In Detail Deceleration stop Setting Range: 0.00 Hz~F0-05 F1-06 Factory default: 0.00Hz braking start frequency Deceleration stop brake Setting Range: 0.000s~32.000s F1-07 Factory default: 0.000s...
  • Page 62 200 Series General Purpose Vector AC Drive Chapter 6 Key Functional Parameter Explanation In Detail will easily overheat and the drive will be easily overcurrent. If the load is heavy and the motor starting torque is not enough, it is recommended to increase this parameter. The torque boost can be reduced when the load is lighter.
  • Page 63 Chapter 6 Key Functional Parameter Explanation In Detail 200 Series General Purpose Vector AC Drive Voltage % V1-V3: Multi-segment V/F 1st~3rd stage Vb:F0-16 voltage percentage F1-F3: Multi-segment V/F 1st~3rd stage V3:F2-08 frequency V2:F2-06 Vb: Motor rated voltage V1:F2-04 Fb: Motor rated frequency...
  • Page 64 200 Series General Purpose Vector AC Drive Chapter 6 Key Functional Parameter Explanation In Detail In order to obtain better vector control performance, motor parameter tuning is required. 0: No operation; The auto-learning is banned. 1: Asynchronous motor dynamic parameter auto-learning To ensure the dynamic control performance of the drive, please select complete tuning, at this time, the motor and load being disconnected, reserve the motor no-load and confirm the motor in the standstill state.
  • Page 65 Chapter 6 Key Functional Parameter Explanation In Detail 200 Series General Purpose Vector AC Drive As shown in the figure above, in this control mode, the ac drive forward running when K1 is closed and reverse running when K2 is closed . K1 and K2 are closed or open at the same time, and the ac drive stops running.
  • Page 66 200 Series General Purpose Vector AC Drive Chapter 6 Key Functional Parameter Explanation In Detail As shown in the figure above, in this control mode, when the SB1 button is closed, press the SB2 button and the drive starts to run . K disconnects the drive for forward rotation, K closes the drive for reverse rotation;...
  • Page 67 Chapter 6 Key Functional Parameter Explanation In Detail 200 Series General Purpose Vector AC Drive counting input" (function 18). When the pulse frequency is high, the S5 port must be used. Set range: 1~32000 F4-30 Set count value Factory default: 1000 Set range: 1~32000...
  • Page 68 200 Series General Purpose Vector AC Drive Chapter 6 Key Functional Parameter Explanation In Detail F5-14 FDT electrical detection value Factory default: 50.00Hz Set Range: 00.00~F0-05 Set Range: 000.0~100.0% F5-15 FDT lag detection value Factory default: 5.0% (FDT electrical level) ON signal is output when output frequency exceeds a setting frequency FDT electrical level until the output frequency is lower than F5-14*( 1000- F5-15), the detail wave form is as the following Fig.
  • Page 69 Chapter 6 Key Functional Parameter Explanation In Detail 200 Series General Purpose Vector AC Drive Output frequency F6-15 F6-02 F6-00 F6-01 F6-16 F6-17 F6-18 Stage0 Stage1 Stage2 SP1 、 T0 、 T1 500ms Pluse Figure 6-11 Simple PLC running diagram Switch frequency point between Set range: 0.00Hz~3000.0Hz...
  • Page 70 200 Series General Purpose Vector AC Drive Chapter 6 Key Functional Parameter Explanation In Detail frequency is less than FA-29, the deceleration time 1 is selected. VF over current speed loss Factory default: 180.0% Set range: 10.0%~210.0% Fb-04 protection point Set range: 0~200...
  • Page 71: Chapter 7 Communication Protocol

    200 Series General Purpose Vector AC Drive Chapter 7 Communication Protocol Chapter 7 Communication Protocol 7.1 Communication Allocation Set baud rate and parity bit through F8-01. 7.2 Salve Machine Address The address of AC Drive should be set through F8-00, 0 is broadcast address, slave address could be set to 1~247.
  • Page 72 Chapter 7 Communication Protocol 200 Series General Purpose Vector AC Drive 3: Over-voltage during stop 4: Over-current during acceleration 5: Over-current during deceleration 6: Over-current in constant speed operation 7: Over-voltage during acceleration 8: Over-voltage during deceleration 9: Over-voltage in constant speed...
  • Page 73: Function Code 06: Stands For The Function Code Of Writing Variable

    200 Series General Purpose Vector AC Drive Chapter 7 Communication Protocol byte; the high byte presents the group serial number of function parameter; the low byte presents function parameter within the group number and need witch to 16 system. 2、For Example...
  • Page 74 Chapter 7 Communication Protocol 200 Series General Purpose Vector AC Drive address could not use to read the AC Drive function parameter. 2、 Examples of communication frame content The dec. time of AC Drive should change to 30.0s through upper machine, corresponding 16 system data is 012CH, and store this setting when power-off.
  • Page 75: Chapter 8 Troubleshooting

    Chapter 8 Troubleshooting 200 Series General Purpose Vector AC Drive Chapter 8 Troubleshooting The possible faults of 200-N is listed below , and the fault code indicate range is from E001 and E003 ~ E041. Once a fault occurs, you may check it according to the table and record detailed phenomena before seeking service from the supplier.
  • Page 76 200 Series General Purpose Vector AC Drive Chapter 8 Troubleshooting Fault Fault categories Possible reasons of fault Actions code The drive's and motor's power not Use suitable motor matched with each other Too short Acc time Prolong the Acc time...
  • Page 77: Common Fault And Handling Methods

    Chapter 8 Troubleshooting 200 Series General Purpose Vector AC Drive Fault Fault categories Possible reasons of fault Actions code Check the motor’s wiring, parameters’ Overtime of auto-learning settings Press STOP/RST to reset EEPROM R/W R/W fault of control parameters Seek service...
  • Page 78 200 Series General Purpose Vector AC Drive Chapter 8 Troubleshooting Phenomena Possible reasons of fault Actions Drive's input supply is inconsistent with the Check with a multi-meter and The drive doesn’t rated voltage troubleshoot the issue. display after 3-phase rectifier bridge blasted...
  • Page 79 Appendix 200 Series General Purpose Vector AC Drive Appendix 1 Wiring diagram of 230 special purpose ac drive for ball mill AC380V...
  • Page 80 200 Series General Purpose Vector AC Drive Appendix Appendix2 Wiring diagram of 230 vector ac drive for engineering type...
  • Page 81 Guarantee Agreement Warranty of the company products executes in accordance with "the quality assurance" in instructions. 1. Warranty period is 12 months from the date of purchasing the product 2. Even within 12 months, maintenance will also be charged in the following situations: 2.1.Incorrect operation (according to the manual) or the problems are caused by unauthorized repair or transformation.

This manual is also suitable for:

200-g0.4t4b-n200-g0.75t4b-n200-g1.5t4b-n200-g2.2t4b-n200-g3.0/p3.7t4b-n200-g3.7/p5.5t4b-n ... Show all