Reassembly - Philips 3000 Series Service Manual

Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

Disassembly- and Reassembly advice
• Now the Motor housing can be removed by
lifting: Grip on back side with one hand, with
other hand push down in the Dust chamber.
• To replace the motor (37) and PCB (32):
The PCB is connected to the Motor with 2 wires
through the Motor housing.
Remove the Motor housing Cover by unclicking
the 3 clicks.
Watch out: Valve assy spring jumps out !
Remove the Motor rubber (38).
Pull the motor to the outside and remove the 2
X
Y
wires
and
connected to the PCB.
Now the motor and PCB can be replaced.
(see exploded view)

Reassembly

• The Motor rubber needs to be replaced correctly,
safety valve can be replaced and afterwards the
Motor housing cover can be clicked on.
• Replace Motorassy in the Lower housing.
• Fix all the screws (E).
• Replace the Cordwinder assy and reconnect de
2 wires to the PCB on the Motor housing.
• First leed the cord through the Cord outlet, then
the Cordwinder assy can be replaced.
• Keep the cable and plug in its original position!!!
• Replace the Top housing and fix all the screws
(B) and (C).
• Now the Dustcover assy can be replaced by
using a screwdriver.
• Remark: Safety valve cannot be supplied
separately, make sure that this can be re-used.