Table of Contents AP BIO 400/500/1000/2400 Unit type code ................3 Overview of Units and Packaged Content ........ 4 2.1 Series ......................4 2.2 Packaged content ..................4 Safety and User Information ............5 3.1 Availability of the operation manual ............5 3.2 Scope of the operation manual ..............
Unit type code AP BIO 400/500/1000/2400 Unit type code FläktGroup AP BIO Series Product line AP BIO 04 - 400 05 - 500 Size 10 - 1000 24 - 2400 Filter set B - biological (anti virus & bacteria) Control S - standard system Fan control...
Overview of Units and Packaged Content AP BIO 400/500/1000/2400 Overview of Units and Packaged Content Series For detailed information on individual unit series refer to the data sheets or the quotation text for the unit. Packaged content The following components are included in the packaged content: –...
Safety and User Information AP BIO 400/500/1000/2400 Safety and User Information This is an original operation manual verified by the manufacturer. FläktGroup AP BIO series units are constructed using state-of-the-art technology and according to recog- nized safety regulations. Use the FläktGroup units only in a technically sound condition for the intended purpose, observing the current operation manual and taking safety aspects and potential hazards into account.
Safety and User Information AP BIO 400/500/1000/2400 Identification of safety instructions The following designations/symbols are used in this manual to specify safety instructions: 3.4.1 DANGER – Death/serious irreversible injury Indicates an (extremely) hazardous situation which will result in death or serious irreversible injury if the safety instructions are not followed.
Safety and User Information AP BIO 400/500/1000/2400 3.4.4 ATTENTION – Environmental or material damage ATTENTION Indicates actions that can result in damage to equipment or property. Examples: ATTENTION Environmental damage! Heavily contaminated filters can have a negative impact on production processes. Depending on the filtered-out materials, contaminated filters are therefore classi- fied as hazardous waste and must be properly disposed of according to the pre- vailing directives and laws.
Safety and User Information AP BIO 400/500/1000/2400 Safety-conscious work procedures When carrying out installation or maintenance jobs FläktGroup recommends to ob- serve the following instructions: • Wear suitable protective clothing during all work, such as protective footwear, gloves, safety goggles, etc. •...
Safety and User Information AP BIO 400/500/1000/2400 Proper use AP BOI air purifiers are only used indoors, i.e. in standard environments according to IEC 60721-3-3 and are designed exclusively for internal filtration and decontamination of air. • Children are not allowed to operate the unit. •...
Safety and User Information AP BIO 400/500/1000/2400 3.11 Spare parts Only original FläktGroup spare parts are allowed, since FläktGroup is not liable if third-party spare parts are used. 3.12 Disposal Equipment and operating supply materials must be disposed of according to material type in an environmentally friendly manner –...
– Low Voltage Directive (LVD) 2014/35/EU – Electromagnetic Compatibility (EMC) 2014/30/EU – Certified Quality Management System ISO 9001 4.1.1 General overview Fig. 4-1 General overview AP BIO 400, 500 and 1000 1: Control panel 2: Indoor air inlet 3: Pre-filter ISO ePM1 55% (F7)
Page 12
Technical Description AP BIO 400/500/1000/2400 Fig. 4-2 General overview AP BIO 2400 1: Control panel 2: Indoor air inlet 3: Access door with key 4: Pre-filter ISO ePM1 55% (F7) and HEPA H14 AirFend filter 5: Power socket with integrated switch 6: Identification plate 7: Rear casters 8: Clean air outlet...
Technical Description AP BIO 400/500/1000/2400 Functional description 4.2.1 AP BIO air purifier (Model 2400) Fig. 4-4 Functional overview 1: Indoor air inlet 2: Control panel 3: Indicator light 4: Fan 5: Air outlets 6: Second HEPA H14 filtration barrier 7: First ISO ePM1 55% (F7) filtration barrier The control panel (2) used to adjust the air flow rate of the unit.
Technical Description AP BIO 400/500/1000/2400 Technical data AP BIO Fig. 4-5 Example dimensions AP BIO 400 AP BIO 400 AP BIO 500 AP BIO 1000 AP BIO 2400 Air flow range 90 - 400 m 90 - 500 m 180 - 1000 m...
AirFlow Surface Type Size Class Frame Gasket Order code AP BIO 400 305 x 305 x 292 galvanized steel U-profile ZAP 04 FB AP BIO 500 305 x 305 x 292 galvanized steel U-profile ZAP 05 FB AP BIO 1000 305 x 610 x 292...
Shipping and storage AP BIO 400/500/1000/2400 Shipping and storage Delivery The units will be delivered with casters and with mounted filters. Upon receipt of the units, inspect them for shipping damage and verify that the ship- ment is complete (refer to chapter 2.2 "Packaged content") according to the freight bill. Take photographs of all visible transit damage.
Shipping and storage AP BIO 400/500/1000/2400 TRANSPORT WITH PACKAGING Only appropriately equipped personnel must perform the transportation in compliance with the applicable safety regulations. Lifting and rigging the unit must only be per- formed using lifting devices appropriately designed to support the entire weight of the unit.
Assembly AP BIO 400/500/1000/2400 Assembly Note on mounting and installing the unit! Here you will find information on how to mount and install the unit. Placement, installation and assembly may only be carried out by qualified specialists with proper professional training and experience in the relevant accident prevention regulations, as well as other generally recognized safety and occupational health codes.
Commissioning and operation AP BIO 400/500/1000/2400 Commissioning and operation ATTENTION Damage to the unit! The unit must not be operated until the proper function tests have been carried out. Overview of the operating elements 7.1.1 Control panel elements Fig. 7-1 Overview control panel 1: Display 2: Increase button 3: Decrease button...
Commissioning • Set the power switch to position ON (I). Refer to: Fig. 4-1 General overview AP BIO 400, 500 and 1000 Pos. 5 and Fig. 4-2 General overview AP BIO 2400 Pos. 5. • After a few moments, the WAIT symbol will disappear from the display.
To cut off the power supply to the unit, set the power switch to position OFF (O). Refer to: Fig. 4-1 General overview AP BIO 400, 500 and 1000 Pos. 5 and Fig. 4-2 General overview AP BIO 2400 Pos. 5.
Presence of a foreign object in the Extract the foreign object. fan area. The access door is not closed properly (AP BIO 400, Close the access door properly. The unit stops working. AP BIO 500 and AP BIO 1000) Electric power supply problem.
Maintenance of the AP BIO AP BIO 400/500/1000/2400 Maintenance of the AP BIO Replacing the filters When the Blocked filter alarm light appears (see Symbols on the control panel display), it is necessary to replace the pre-filter(s) and the AirFend filter(s). The theoretical frequency of changing pre-filters and AirFend filters is 3 months in a high-contamination environment (hospitals in 24/7 mode) and 5 months in other envi- ronments (schools, nurseries, offices, etc.).
Page 24
Wear protective respiratory mask • Exercise due caution and attention when carrying out this work. Fig. 9-1 Replacing the pre-filter AP BIO 400, AP BIO 500 and AP BIO 1000 1: Pre-filter ISO ePM1 55% (F7) 2: Upper bottons 3: Safety lock 4: Access panel •...
Page 25
Maintenance of the AP BIO AP BIO 400/500/1000/2400 Replacing the AirFend filter Fig. 9-2 Replacing the AirFend filter AP BIO 400, AP BIO 500 and AP BIO 1000 1: Lever 2: Filter quick release 3: Access panel 4: AirFend filter H14 •...
Page 26
Maintenance of the AP BIO AP BIO 400/500/1000/2400 9.1.2 Replacing the filters AP BIO 2400 Fig. 9-3 Open the AP BIO 2400 • Unlock the door with a special access key on the middle right side. • Open the first door by pressing with both hands on the door at the points shown in Fig.
Maintenance of the AP BIO AP BIO 400/500/1000/2400 Cleaning the air purifier Electrocution through hazardous voltage will lead to death or serious injury. • Disconnect the unit from the power supply and ensure the power cannot be switched back on. •...
Disassembly and Disposal AP BIO 400/500/1000/2400 10 Disassembly and Disposal ATTENTION Environmental damage! Have qualified licensed staff only dismantle and dispose of the unit! 10.1 Dismantling To dismantle the units, proceed as follows: Electrocution through hazardous voltage will lead to death or serious injury. When carrying out decommissioning and dismantling work on the unit you must: •...
Recycleur portable. Marque: FLAKTGROUP Modèles: AP BIO 400 / AP BIO 500 / AP BIO 1000 / BIO 2400 Directives : Remplissent les exigences de la Directive ErP 2018 Ecodesign. Remplissent les exigences de la Directive 2006/42/CE relative aux machines.
Page 30
Notes AP BIO 400/500/1000/2400 FG-DC_10523-GB_AP Bio_IOM-R0-12/2020 • Subject to modifications...
Page 31
Notes AP BIO 400/500/1000/2400 FG-DC_10523-GB_AP Bio_IOM-R0-12/2020 • Subject to modifications...
Page 32
WWW.FLAKTGROUP.COM AP BIO AIR PURIFIER FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience.