1.0 SAFETY INFORMATION

DO NOT SWITCH OFF THE UNIT – it is designed to run continuously. If the unit is switched
off, indoor pollutants and moisture levels may increase which could endanger your health or
damage your home. It is important to follow the advice in this manual and correctly maintain the
system to ensure a healthy indoor environment.
All wiring must be in accordance with prevailing national regulations, for example the current
IEE Wiring Regulations BS7671. The electrical installation should be inspected and tested by a
suitably qualified person after completion.
The installer is responsible for the installation and electrical connection of this system on site.
It is the responsibility of the installer to ensure that the equipment is safely and securely installed
and left only when electrically and mechanically safe.
When installing the appliance, care should be taken not to damage any hidden utilities.
Ensure that the mains supply (Voltage and Frequency) complies with the rating label.
Isolate from power supply before removing any covers. During installation / maintenance
ensure all covers are fitted before switching on the mains supply.
The appliance should be provided with a local double pole fused spur fitted with a 3 Amp fuse
and a minimum contact separation of at least 3mm.
This unit must be earthed.
Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct
runs terminating close to the fan must be adequately protected by suitable guards.
All regulations and requirements must be strictly followed to prevent hazards to life and
property, both during and after installation and any subsequent servicing or maintenance.
This appliance should not be used by children or persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the safe use of the appliance by a person responsible for their safety.
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried
out by children.
LAB964R | JAnuARy 2021
PAGE 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMX-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Domus Ventilation CMX-S

  • Page 1 CMX-S Central Mechanical Extract Ventilation (cMEV) appliance Installation Instructions 1.0 SAFETY INFORMATION DO NOT SWITCH OFF THE UNIT – it is designed to run continuously. If the unit is switched • off, indoor pollutants and moisture levels may increase which could endanger your health or damage your home.
  • Page 2 In dwellings where it is intended to install open-flue appliances and extract ventilation, the • combustion appliance should be able to operate safely, whether or not the fans are running. A way of showing compliance with The Building Regulations in these circumstances would be to follow the installation guidance shown below, and to show by tests that combustion appliances operate safely, whether or not the fans are running.
  • Page 3 2.0 GENERAL DESCRIPTION 2.3 Remote / Automatic Control Options (Supplied Separately, Wiring Section 5) The CMX-S appliance is a key part of a whole house ventilation system • Adjustable overrun timer, code AnC108A. specifically designed to improve indoor air quality in dwellings. The •...
  • Page 4 DDSEAL acrylic sealant; failure to do this will cause unnecessary air leakage and impair performance. Using the arrows moulded into the body of the CMX-S appliance as a guide, ensure that the direction of airflow is from the ‘wet rooms’ to the outside.
  • Page 5 5.0 REMOTE / AUTOMATIC CONTROL WIRING 5.3 ANC802A (Humidistat With Timer), ANC846A (Humidistat With Timer And Remote Sensor), ANC808A - Humidistat With Pull Cord 5.1 ELE150R (Switched Live Extension Board) AnC801A, AnC846A & AnC808A Wiring ELE150R Wiring 5.4 ANC813A (PIR With Overrun Timer) 5.2 ANC108A (Overrun Timer) AnC813A Wiring AnC108A Wiring...
  • Page 6 Domus Ventilation itself. Where owner upon completion of the installation.
  • Page 7 10.0 AFTER SALES AND REPLACEMENT PARTS For technical assistance or further product information, including spare parts and replacement components, please contact the After Sales Department. If ordering spares please quote the serial number of the unit together with the part number, if the part number is not known please give a full description of the part required.
  • Page 8 Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. Domus Ventilation Block C, Van Court, Caerphilly CF83 3ED, united Kingdom Email: vent.info@domusventilation.co.uk Tel: 03443 715 523 www.domusventilation.co.uk...

Table of Contents