  • Page 1 PRODUCT USER GUIDE MetroLED Configurable Lighting Rev: C1 PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE METROLED SYSTEM...
  • Page 2 • UFO MetroLED SP - Special Extrusion INTRODUCTION The UFO MetroLED is a fully configurable LED track lighting system which has been especially designed for ease-of-use and many installation environments. Available in multiple configurations and with spotlight and linear lighting modules both available with a choice of 3000K or 4000K light outputs.
  • Page 3 Component Parts List before commencing your build (see the Component Parts Section in this User Guide) PREPARE THE 12V PSU The MetroLED flexible lighting track system is powered from EITHER a multifunction, multi-voltage, 4 Amp desk top Power Supply Unit, OR an IEC input, multi-voltage boxed PSU. 4A DESKTOP PSU Remove the Desk Top PSU from its box.
  • Page 4: Component Parts

    USA plugs. Plug the mains lead into the IEC socket on the PSU – see below. The PSU is now ready for power. DO NOT CONNECT PSU TO DIMMER UNTIL METROLED TRACK SYSTEM IS FULLY ASSEMBLED AND THE DIMMER IS CONNECTED COMPONENT PARTS MetroLED component parts are detailed below.
  • Page 5 INTRODUCTION COMPONENT PARTS MetroLED component parts are detailed below. Item Description Extrusion end cap 45° end fitting Power in connector Left hand rotating corner (static corner also availbale) Right hand rotating corner (static corner also available) Corner 30m foot, unthreaded, screw plate...
  • Page 6 ASSEMBLY ACCESS PLATE REPLACEMENT PROCEDURE METROLED USER GUIDE...
  • Page 7 SLIDE ON PARTS Most MetroLED systems are shipped either fully or partly assembled. All LEDs should be already fitted to the 3 track extrusion. Assembly therefore will generally involve fitting together extrusions. Gantry Legs will be marked “Left” and “Right” to avoid confusion. CAUTION –...
  • Page 8 See examples below. Correct - pins facing the right way Incorrect - pins facing the wrong way Pushing LED fittings on the wrong way will irreparably damage the spring contacts Correct - pins facing the right way METROLED USER GUIDE...
  • Page 9: Lock Parts

    Care must be taken to push the fitting firmly down so that it is fully sitting in the track extrusion. If not fully inserted when twisting to lock, the plastic housing may become damaged which will result in the fitting not being locked in. UFO LIGHTING...
  • Page 10: Operation

    There are 3 electrical connections required before connecting the system to the mains – see drawing below: 1. Connect the extrusion power In connector track power cable to the MetroLED dimmer ensuring correct wire colour codes 2. Connect the dimmer box and cable to MetroLED dimmer ensuring correct wire colour codes 3.
  • Page 11: Operation And Maintenance

    OPERATION & MAINTENANCE ELECTRICAL CONNECTIONS The MetroLED Dimmer unit has two +ve track outputs which are limited to 3 Amps – exceeding the load on either track will cause the overloaded track to shut down and the overload indicator LED to illuminate.
  • Page 12: Troubleshooting

    fittings until overload not working LED extinguishes MetroLED dimmer overload LED Disconnect +ve wire to illuminated overloaded track at MetroLED MetroLED dimmer faulty dimmer. If LED remains illuminated replace dimmer Bad connection on Inspect joint, check connection rotating joint and ensure fully inserted LEDs on one part of fixture/gantry not...
  • Page 13: Hand Tools

    CONSTRUCTION CONSTRUCTION GUIDE This section is intended to assist approved constructors who will be cutting and preparing MetroLED. This section should be read in conjunction with the Constructors UFO 5 part video guide. HAND TOOLS 1. PPE Safety glasses (minimum requirement) 2.
  • Page 14: Cutting Tools

    The powered chop saw used by UFO is a Proxxon KGS 80 with a carbide tipped, blade having 36 teeth. The saw and blades are widely available in a 110V version in the USA or 240V versions in Europe.
  • Page 15 Insert the UFO extrusion tool into the extrusion through 90�� as shown in sketch overleaf. Clamp the extrusion and the UFO Extrusion Tool in the chop saw vice (use protective pads on the vice jaws to avoid scratching the paintwork) as shown below.
  • Page 16 CONSTRUCTION Once cut, the copper track ends must be prepared to accept the MetroLED fittings. Clamp the cut extrusion using the UFO extrusion tool as shown below (use protective material underneath the extrusion to avoid scratching the paintwork) Once clamped, carefully file the ends of the copper track to an approximate 30°angle. This angle allows the MetroLED push fit devices, electrical spring contacts to be pushed onto the track without damage, see images below.
  • Page 17 In the event of the copper track coming out of its holder (see below) the following reparative action can be taken. Insert the UFO Extrusion Tool into the extrusion prior to the raised copper track and pressing down firmly slide the tool along and over the raised track pushing it back down into its holder.
  • Page 18: Technical Specification

    INSTALLATION USING C CLIPS UFO supply C-clips for both round & rectangular MetroLED extrusions. Please ensure that: - A clip is installed at least at either end and in the centre of all runs of extrusion. - For extrusions of 1 metre or less, a minimum of 3 clips must be used.
  • Page 19: Led Specification

    3000K 0.8W 160mA ­ Linear Light 95mm 4000K 0.8W 160mA ­ Linear Light 245mm 3000K 2.3W 460mA ­ Linear Light 245mm 4000K 2.3W 460mA ­ 300mA per Overload indication MetroLED Driver Version 2 channel and shut down NOTES UFO LIGHTING...