    POS-SCANNER TABLE OF CONTENTS ASSEMBLY ................................1 1.1............................2 ASSEMBLY ELEMENTS 1.2. ASSEMBLY PROCEDURE ..........................2 1.2.1. Assembly of the Weighing kit in the scanner chassis.................. 2 1.2.2. Leveling............................... 4 1.3..............................5 LATE MOUNTING CONNECTIONS............................... 6 2.1.
  • Page 5: Assembly

    TEST AND AJUSTMENT MANUAL ASSEMBLY 49-TPOSE-PSC-EN02...
  • Page 6: Assembly Elements

    POS-SCANNER 1.1. ASSEMBLY ELEMENTS 1.- Weighing kit ( including CPU, loadcell and plate holder). This kit is already assembled. 2.- Column with two displays ( vendor and buyer) including the connection cable between scale and display. 3.- Connection cable scale-scanner (Ref: BB-5897).
  • Page 7 TEST AND AJUSTMENT MANUAL Once the kit is placed in the right position, it must be screwed by means of the 4 allen screws. 49-TPOSE-PSC-EN02...
  • Page 8: Leveling

    POS-SCANNER 1.2.2. Leveling Once the kit has been screwed, the scale must be leveled by means of the vial placed in the front of the scale. To modify the leveling, the legs of the scale must be turned. Turn the legs for levelling...
  • Page 9: Plate Mounting

    TEST AND AJUSTMENT MANUAL 1.3. PLATE MOUNTING Place the plate on the plate holder and verify the right leveling of the plate by means of an external level. To fix the levelling of the plate, use the plate leveling screws. Once the plate is leveled, the position of the screws must be fixed by means of an adhesive type LOCTITE 242 or similar.
  • Page 10: Connections

    POS-SCANNER CONNECTIONS 2.1. CONNECTION SCALE-SCANNER The reference of the connection cable Scale-Scanner is BB-5897. This cable must be plugged in one side in the coonector marked as SCALE SCANNER of the scale and in the other side in the connector marked as AUX PORT of the scanner.
  • Page 11: Connection Scale-Display

    TEST AND AJUSTMENT MANUAL 2.2. CONNECTION SCALE-DISPLAY The connection cable display-scale is supplied mounted and plugged in the displays, the other side must be plugged in the connector marked as SCALE DISPLAY of the scale. 2.3. MAINS SUPPLY CONNECTION The connection of the scanner to the mains supply must be done by means of the connector and the supply cable of the scanner.
  • Page 12: Test

    POS-SCANNER TEST The test functions permit the user to check all of the important elements of the scale in order to assure that they function correctly; or in the case of a malfunction, find the faulty element quickly. The scale must be turned off to leave test mode.
  • Page 13: Adjustment

    TEST AND AJUSTMENT MANUAL ADJUSTMENT These functions allow the user to program, adjust and calibrate the scale. IMPORTANT NOTE: this should only be done by authorized personnel. The scale must be turned on for at least two hours before being adjusted. It must also be perfectly level and the temperature and humidity must be stable.
  • Page 14: Latitude Adjustment

    POS-SCANNER 4.4. ADJUSTMENT. This allows an adjustment to be done. The default value of 0 will always be shown. Change this to a value of 1 and press the ‘*’ key. Do not enter this option if you are not qualified or if you do not have the calibrated weights.
  • Page 15: Weight Adjustment

    TEST AND AJUSTMENT MANUAL 4.8. WEIGHT ADJUSTMENT. Once the zero weight adjustment is made, the display will show a default weight, relative to the scale capacity, to be used in the weight adjustment. This adjustment weight may be modified by using the keyboard.
  • Page 16: Telecharge

    POS-SCANNER TELECHARGE The reference of the Telecharge cable is BB-5918. 5.1. DESCRIPTION OF TELECHARGE CABLE BB-5918 5.2. CONNECTION FOR TELECHARGE The Telecharge cable Ref: BB-5918 must be connected to the Telecharge connector of the CPU. TELECHARGE CONNECTOR 49-TPOSE-PSC-EN02...
  • Page 17: Communications

    TEST AND AJUSTMENT MANUAL 5.3. COMMUNICATIONS The cable to connect the scale to PC or POS has the reference BB-5896 and it must be plugged in the connector marked as SCALE COM of the scale. Never use a communications cable different to the one shown above. 49-TPOSE-PSC-EN02...
  • Page 18: Programming Of Communications

    POS-SCANNER 5.4. PROGRAMMING OF COMMUNICATIONS. 5.4.1. Communication characteristics For programming of communications, the process is as follows: Enter test mode by simultaneously pressing while the scales are effecting the countdown after switching on. Press Select the type of communication in accordance with the table...
  • Page 19: Characteristics Of The Protocols

    TEST AND AJUSTMENT MANUAL 5.5.2. Characteristics of the protocols Protocol Type Protocol Type 1-ANKER 8-DELTA 2-CASIO CE at 9600 9-ALFA 2-CASIO CE at 2400 10-SAMSUNG ESPAÑA 3-RIVA 11-SAMSUNG PORTUGAL 3-UNIWELL 12-UNIPROX 4-TISA 12-BMC PS2000 5-EAN at PC ICL 13-UNIPROX (with checksum) 6-SANYO 14-SHARP UP700 7-APOLLO/SAMSUNG POLONIA...
  • Page 20: Protocols Type

    POS-SCANNER 5.7. PROTOCOLS TYPE 5.7.1. Anker Cash Register Protocol Protocol Cash register Scales PPPPE WWWWWE PPPPPE IIIIIIE Where. 0x02h : 0x06h 0x30 y 0x31h 0x1Bh 0x03h WWWWW: 5 digits for the WEIGHT. PPPPP: 5 digits for the PRICE. IIIIII: 6 digits for the SUM 5.7.2.
  • Page 21: Riva / Uniwell Cash Register Protocol

    TEST AND AJUSTMENT MANUAL 5.7.3. Riva / Uniwell Cash Register Protocol Protocol Cash register Scales iWWWWWC E iWWWWWC E Where: 0x05h 0x06h 0x11h 0x02h 0x69h WWWWW: 5 digits for WEIGHT Checksum, logical sum (XOR) starting from i. 0x03h : 0x0Dh 5.7.4.
  • Page 22: Sanyo Cash Register Protocol

    POS-SCANNER 5.7.6. Sanyo Cash Register Protocol Protocol Cash register Scales A28PPPPkIIIIIKC Where: 0x05h : 0x06h PPPP: 4 digits for the PRICE Partial checksum of the first 7 characters sent IIIII : 5 digits for the SUM Total checksum of the 13 characters sent.
  • Page 23: Alfa Cash Register Protocol

    TEST AND AJUSTMENT MANUAL 5.7.9. Alfa Cash Register Protocol Protocol Cash Register Scales SWWW.WWWC Where: Sign. +: 0x2Bh -: 0x2Dh WWWWWW: 6 digits for WEIGHT. 0x2Eh 0x0Dh 0x0Ah 4.3.10. Samsung-Spain Cash Register Protocol Protocol Cash Register Scales WW.WWWC Where: 0x24h WWWWWW : 6 digits for WEIGHT.
  • Page 24: Uniprox With Checksum Cash Register Protocol

    POS-SCANNER 4.3.13. Uniprox With Checksum Cash Register Protocol Protocol Cash Register Scales 28PPPPCWWWWWkC Where: 0x32h 0x38h PPPP : PLU code. Partial Checksum (XOR of previous characters) WWWWW : 5 digits for WEIGHT 0x0Ah Total Checksum : 0x0Dh 4.3.14. Sharp Up-700 Cash Register Protocol...
  • Page 25: Kabel Cash Register Protocol

    TEST AND AJUSTMENT MANUAL 4.3.15. Kabel Cash Register Protocol Protocol Cash Register Scales ) ó (D WWW.WWWxE Where: 0x02h 0x7Ah 0x03h 0x75h 0x13h 0x57h 0x14h WWW.WWW: 6 digits for WEIGHT. 0x2Eh 4.3.16. Nci Cash Register Protocol Protocol Cash Register Scales 1) Weight request xx.xxx Kg C 2) Status request...
  • Page 27 TEST AND AJUSTMENT MANUAL True copy of the manual deposited with notified body Nº 317 The information in this manual may be modified by the manufacturer without prior notice. Ref.: 49-TPOSE-PSC-EN02 REV 03 10/04/07 49-TPOSE-PSC-EN02...