Download Print this page

VATA 2365 User Manual

Advanced venipuncture training aid

Advertisement

Quick Links

Advanced Venipuncture
Training Aid
– 2365/2366
USER MANUAL
308 South Sequoia Parkway, Canby, Oregon 97013 USA
ph. 503.651.5050 | fax 503.651.5052 | email info@vatainc.com | www.vatainc.com

Advertisement

loading

Summary of Contents for VATA 2365

  • Page 1 Advanced Venipuncture Training Aid – 2365/2366 ™ USER MANUAL 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 | fax 503.651.5052 | email info@vatainc.com | www.vatainc.com...
  • Page 2 The Advanced Venipuncture Training Aid™ – 2365/2366 features four barely discernable blue veins of 3 different diameters – with the fourth vein deeply placed – in a semi-transparent, tissue-like pad.
  • Page 3: Product Components

    Product Components Base Vein pad of Dermalike II™ Hinged cover plate for vein pad Bubble Trap White Cap Bubble Trap Blood Bag with Simulated Blood Stopcock 2366 Darkly Pigmented www.vatainc.com...
  • Page 4: Helpful Hints

    See video: www.vatainc.com/2365video • The simulated blood provided is only for use in models and is not intended for any other use. To replace, use VATA’s simulated blood, items #1491 quart or #1494 gallon. We do not recommend using VATA’s...
  • Page 5: Setup Instructions

    Set-up Instructions 1. Place finger on tab and push in to open hinged cover. 2. Open cover to a vertical position until an audible “click” is heard, confirming the top is in the locked position. 3. Remove bubble trap from holder. 4.
  • Page 6 Set-up Instructions, Cont. 5. Turn handle on stopcock to a vertical position; model will prime in under 1 minute. 6. Model is primed when simulated blood is visible in the bottom of the bubble trap. If model does not prime see next step.
  • Page 7: Storing Instructions

    Storing Instructions 1. Remove stopcock from the cover. 2. Remove the simulated blood bag from the hook on the cover. 3. Place simulated blood bag below the level of the vein pad and simulated blood will drain from the model in under 1 minute.
  • Page 8 Storing Instructions, Cont. 5. When the model is completely drained, turn the handle on the stopcock to a horizontal position. 6. Place the simulated blood bag back onto the hook in the cover. 7. Snap the stopcock back into the holder –...
  • Page 9 Storing Instructions, Cont. 9. Screw cap back onto the bubble trap. 10. Snap bubble trap into holder – an audible “snap” will confirm proper placement. 11. Stabilize base and apply closing pressure to cover to release from the locked position – an audible “click” will confirm disengagement.
  • Page 10 Care & Filling of Simulated Blood Bag The model is supplied with a simulated blood bag containing 80 cc. When simulated blood needs to be added to the bag, close the stopcock by turning to a horizontal position. Remove bag from hook in cover.
  • Page 11 Advanced Venipuncture Training Aid™ Lightly Pigmented 2366 Advanced Venipuncture Training Aid™ Darkly Pigmented 0385 Optional Carrying Case for items 2365 & 2366 2367 Simulated Blood Reservoir – with Stopcock 2368 Replacement Bubble Trap 2381 Vein and Tissue Pad Replacement, Lightly Pigmented...
  • Page 12 You Might Also Like These Products... 1352 1353 Two-Vein Venipuncture Training Aid, Lightly Pigmented - Dermalike II™ – 1352 Two-Vein Venipuncture Training Aid, Darkly Pigmented - Dermalike II™ – 1353 1354 1355 Four-Vein Venipuncture Training Aid, Lightly Pigmented - Dermalike II™ – 1354 Four-Vein Venipuncture Training Aid, Darkly Pigmented - Dermalike II™...

This manual is also suitable for:

2366