Do you have a question about the GENIUS MT and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Termo GENIUS MT
Page 1
GENIUS MT SIZES: 6-11, 10-11, 20-11, 20-21 ENERGY TYPE: ELECTRIC, GAS Translation of the original operating instructions Subject to technical changes. Read carefully before use. Keep safe for future use. LEGAL NOTICE www.termo.no...
Page 2
T. +47 701 97 500 F. +49 (0) 8141 395-130 Visit our website www.termo.no For user tips and recipies You can contact us almost 24 hours a day, 7 days a week, 365 days a year: T. +47 701 97 522 E.
Operating modes ..................20 Additional features ..................21 Special programmes ................... 22 HACCP report....................23 USB interface ....................23 Appliance structure and operation ........24 Appliance general structure ..............24 Structure operation ..................26 Opening and closing the door ..............27 www.termo.no...
Page 4
Ongoing operation of the cooking and baking process operation ..........................92 Last® 20..................104 Call up Last® 20................... 104 Programme list/favourites ............111 10.1 Starts the programme .................111 10.2 Programme list options/favourites options .........111 10.3 Searching, changing and starting programmes/favourites ..114 www.termo.no...
Page 5
Manual cleaning of other parts of the appliance ......155 14.5 Semi-automatic cleaning ................. 156 14.6 Fully automatic cleaning (autoclean®) ..........158 14.7 Exiting cleaning ................... 161 QuickMode ..................163 15.1 QuickMode ....................163 15.2 Directmode ....................166 Settings and Service ..............172 16.1 Changing the general settings............... 174 www.termo.no...
Page 6
17.2 Eliminate faults .................... 212 Maintenance instructions ............214 18.1 Level monitoring Eloma liquid cleaner PRO or Eloma rinse aid 214 18.2 Water treatment ..................215 18.3 Starting up the cleaning programme ..........216 Disposal and environmental protection ......218 www.termo.no...
Every update or supplement published by the manufacturer must be added to the operating instructions. We recommend that you add additional instructions, including responsibilities for the supervision and reporting of specific aspects of operation, e.g. relating to work organisation, work procedures or the employed staff. www.termo.no...
Improper commissioning, improper operation or incorrect maintenance of the device. • Faults which are caused by failure to adhere to these installation and operating instructions. You will find detailed information on liability for material defects and the warranty in our general terms and conditions. www.termo.no...
Action to prevent the hazard. NOTE Type and source of hazard Consequence: Failure to observe will lead to material damage. Action to prevent the hazard. INFORMATION: Tip on operation. Tab. 2: Meanings of the pictograms and signal words used www.termo.no...
MARKING! "Equipotential bonding connection!" MARKING! "Connections for hard and soft water" MARKING! "Connections for cleaner and rinsing agent" MARKING! "Waste water connection" MARKING! "Completed device testing and quality control" Tab. 3: Overview of the device signs used www.termo.no...
– Persons who do not possess the aforementioned qualifications – Persons with limited psychological, sensory or mental abilities Make sure that repairs and maintenance work on the device are only carried out by an authorised Eloma service partner. www.termo.no...
Notify the fire services. – Extinguish fat fires with a fire extinguisher for class F fires. Never use water. Extinguish other fires, e.g. with an ABC extinguisher, CO2 extinguisher or an extinguishing agent suitable for the respective fire class. www.termo.no...
Page 14
(recommended maximum insert height approximately 1.60 m from the access level). Fig. 1: Sticker, Caution! Hot fluids in insert containers (included with delivery) www.termo.no...
Page 15
Only connect USB sticks with a Flash memory. Do not use force to insert USB sticks. Always insert USB sticks before reading/writing and do not remove them until the data transfer has been completed. www.termo.no...
Page 16
On devices with an autoclean® cleaning programme: Keep the cooking chamber door closed at all times whilst the autoclean® cleaning programme is in progress. The "Do not open door!" symbol is highlighted in red on the display screen. www.termo.no...
Page 17
Risk of asphyxiation and explosion in case of gas leakage! Adhere to the rules of conduct in case of a gas leakage (see section 2.2.1). Adhere to the maintenance intervals (see section Fehler! Verweisquelle konnte nicht gefunden werden.). www.termo.no...
Page 18
Have maintenance work is carried out by an authorised Eloma service partner only. Adhere to the maintenance intervals (see section Fehler! Verweisquelle konnte nicht gefunden werden.). Adhere to the rules of conduct in case of fire (see section 2.2.1). www.termo.no...
The user and operating instructions for user support, settings and running operation can be found in Section 7 Manual cooking / Manual baking, and instructions on the topic of multiple selection for parallel operation can be found in Section 12 Multi cooking PRO/Multi baking PRO. www.termo.no...
The additional timer function can be used to enter a time at which the cooking programme is to start or end. An end time cannot be set if a cooking step is controlled by the core temperature. Available in all operating modes. www.termo.no...
The cooking step ends as soon as the temperature reaches the set target core temperature. 3.4.3 Regenerating Regeneration can be used to reheat fully cooked foods gently after they have cooled. www.termo.no...
• Cooking/baking programmes • Protocols (HACCP, fault lists, log files) • Images • Sounds 3.6.2 USB to device DATAtransfer The following data can be copied from the USB stick to the device: • Cooking/baking programmes • Images • Sounds www.termo.no...
– Double glazing on door with LED lighting and triple glazing Cooking chamber door Drip tray Hand shower Cooking chamber Ventilation slats USB connection port with locking panel Operating panel with On/Off key Supply air opening Exhaust air pipe www.termo.no...
Page 25
Double glazing on door with LED lighting and triple glazing Cooking chamber door Drip tray Cooking chamber USB port Ventilation slats Hand shower Operating panel with On/Off key Supply air opening Exhaust air pipe Exhaust gas pipe draft diverter (for gas devices) Emergency opening handle Tray trolley www.termo.no...
Special programmes, Weekly programming PRO, Multi Baking PRO, Cleaning and care, Settings and service. USB port with cover – Data exchange between other devices or PC via USB sticks (software updates, programmes, images, sounds, protocols, etc.) Fig. 4: Operating panel www.termo.no...
4.3.2 Opening a door with safety door lock (optional) Push the door handle down. – The device door latches in the ventilation position. – The door handle moves back into the latched position. Allow steam to escape. www.termo.no...
1.60 m, measured from the access level. Always remove the containers in a horizontal position and, wherever possible, only move them with a cover attached. www.termo.no...
Page 29
INFORMATION: • Transport the tray trolley/mobile plate rack for table-top devices with a transportation trolley! • Only use a transportation trolley if the table-top device is placed on a base frame or base cabinet of the same height. www.termo.no...
Page 30
Position the transportation trolley as near as possible to the table-top device. Apply the brake on the castors of the transportation trolley. Push the tray trolley/mobile plate rack through the insertion frame and onto the transportation trolley. Secure the tray trolley/mobile plate rack on the transportation trolley. www.termo.no...
Page 31
Open the cooking chamber door at the end of the cooking process. Attach the bow handle. Release the brakes on the castors with brakes. Roll out the tray trolley/mobile plate rack. Fig. 8: Tray trolley with bow handle without containers www.termo.no...
Page 32
Adhere to the direction of the arrow on the frame and handle. Only use the supplied handle. CAUTION! Material damage due to protruding handle! Door glass breakage. Remove the handle before closing the cooking chamber door. www.termo.no...
The device is ready for operation. 4.5.2 Swichting on the device for long breaks in operation (idle mode) Open the operating company's water connection. Press the On/Off key. – The start setting is displayed. – The device is ready for operation. www.termo.no...
This duration can be modified by qualified personnel. 4.6.2 Switching off the device for longer breaks in operation (idle mode) Press the On/Off key. – The display is extinguished. Close the operating company's water connection. Open the cooking chamber door. www.termo.no...
When the power supply is restored, the device runs in standby mode. Further instructions (continue or cancel cooking programme) are displayed. INFORMATION: Power failure during the autoclean® programme: Only safety rinsing can be started; no other function is available. Fig. 10: Screen after unexpected deactivation (e.g. power failure) www.termo.no...
The hand shower may only be used to clean the cooking chamber, not for cooling. Pull out the hose with hand shower by the hose. Hold the hand shower firmly when using it. To wind on the hand shower, allow it to slowly slide back into the mount. www.termo.no...
Page 37
Two probe variants are available: • External core temperature probe • External sous vide probe (for vacuum cooking) Fig. 11: Connection socket for external core temperature probe and sous vide probe Fig. 12: External core temperature probe and sous vide probe with connection www.termo.no...
Page 38
The core temperature probe can be plugged into the next product and the core temperature sensor feature will continue to be on. No repeated starting/no need to re-enter the entire programme. Cooking with the core temperature probe will only be stopped when Stop is selected. www.termo.no...
Field Bestätigen (Confirm) Confirm selection/entry, entries and changes are accepted. Field Schließen (Close) Close selection/entry, entries and changes are not accepted. Tab. 6: Symbols used during startup Fig. 13: screens Willkommen (Welcome) and Allgemeine Einstellungen (General Settings) at StartUp www.termo.no...
) / ( Einstellen Uhrzeit (time setting) screen is displayed. Set the hours and minutes using the number field or the ( ) / ( ) keys. Confirm/cancel with ( ) / ( Allgemeine Einstellungen (general settings) screen is displayed. www.termo.no...
Allgemeine Einstellungen (general settings) screen is displayed. Allgemeine Einstellungen (General Settings) Open the keyboard field in the screen with ( Select a keyboard in the scroll field. Confirm/cancel with ( ) / ( Allgemeine Einstellungen (general settings) screen is displayed. www.termo.no...
Select the (Existing) programme list field in the scroll field. Confirm/cancel with ( ) / ( Allgemeine Einstellungen (general settings) screen is displayed. 5.3.2 Loading your own programme lists Fig. 17: Screens Upload eigener Programmlisten (Uploading custom programme lists) USB stick www.termo.no...
Page 43
Plug in the USB stick and confirm with ( Upload-Fortschritt (Upload Progress) screen is displayed. INFORMATION: If the upload was not completed, an error message “Upload failed” will appear. Allgemeine Einstellungen (General Settings) screen is displayed after successful upload. www.termo.no...
Open the Stand-by Bild (Stand-by Image) field in the Einstellungen (General Settings) screen with ( A screen with a (pre-installed) selection of standby images appears. Highlight the stand-by image. Confirm/cancel with ( ) / ( Allgemeine Einstellungen (General Settings) screen appears. www.termo.no...
Page 45
The following selection options are available: • 15 min, 30 min, 45 min and 60 min Select the desired time field. The line is displayed in blue. Confirm with Continue in the Startup screen. Auswahl Startbildschirm (Start screen selection) screen appears. www.termo.no...
Page 46
Home screen with direct programme access Select the desired start setting. Confirm with Continue in the Startup screen. Auswahl Vorgabe (Default selection) Individuelle Passworteinstellungen (Custom Password Settings) screen appears. Fig. 22: Screen Auswahl Vorgabe (Default selection) Individuelle Passworteinstellungen (Custom Password Settings) www.termo.no...
Page 47
Confirm the Standard field if default passwords are to be used OR define your own passwords, then enter new passwords for the different access levels. The screen for entering the password for the desired level appears. 10. Enter passwords for different access levels. www.termo.no...
Page 48
Fig. 24: Screen Display mode selection greyed out/enabled Select a greyed out/enabled display mode and confirm with Continue. Anzeige Setup-Ende (Setup end display) is shown. Fig. 25: Screen Anzeige Setup-Ende (Setup end display) After confirmation, the system is restarted. www.termo.no...
Allgemeine Einstellungen (General Settings) screen appears. Scroll to the Restart Startup field and select. The screen with the control question appears. Confirm/close with ( ) / ( If confirmed, startup will be performed again after the next appliance start. www.termo.no...
Manuelles Kochen (Manual cooking) Switch to the home screen. Field Manual baking Manuelles Backen (Manual baking) Switch to the home screen. Field Last® 20 Display the list of the last 20 cooking and/or baking programmes called up. www.termo.no...
Page 51
A description of the icons appears on all screens. Notes & Errors (on all screens only in case of errors, malfunctions or notes) Switch to the specific error code by touching it. Tab. 7: Elements of the start screen www.termo.no...
By selecting it, the operator opens another screen with various options. • Field Ändern (Change) • Field Display/Change Programme Details • Field Schließen (Close) Field Start • Programme is started. Tab. 8: Elements on the home screen with direct access to the programmes www.termo.no...
Page 53
Fig. 29: Screen und programme information Programmdetails (Programme details) INFORMATION: Last®20, programme list or favourites can be set to be directly displayed in Settings and service. NOTICE Touch the desired function field on the touch screen to continue. www.termo.no...
If active, the filed will be highlighted in blue. Temperature, humidity, cooking/baking time and core temperature settings and active additional features are displayed. Touch the desired value field (e.g. Temperatur (Temperature)). The input screen (e.g. temperature) will appear. Set/change values (e.g. temperature, see below). www.termo.no...
Page 55
Field Schrittgarzeit (Step cooking time) Changing to the step cooking time (h:min:sec) set. Field Schrittgarzeit (Step cooking time) with programme time display (bottom) Field Programmstart (Programme start) Starts the programme. Field Programmstopp (Programme stop) End programme. www.termo.no...
Page 56
Field Schrittübersicht (Step overview) Switch to step overview. Field Home Switch to the home screen. Field Zurück (Back) Switch to the last screen display. Tab. 9: Manuelles Kochen / Manuelles Backen (Manual cooking/baking) screen elements www.termo.no...
Page 57
70 °C 20 °C … 100 °C 158 °F 68 °F … 212 °F Active dehumidification control deactivated (default) Level 5 Active dehumidification control activated (levels 1 to 5, if set) Preheat adjustable Tab. 10: Available settings for manual cooking www.termo.no...
Page 58
(levels 1 to 5 can be selected) Preheat adjustable Tab. 11: Setting ranges for baking INFORMATION: The description of how to set the values applies to all Manual cooking/Manual baking operating modes; any deviations or differences are explicitly pointed out. www.termo.no...
Page 59
– (30 °C/86 °F to 130 °C/266 °F) by means of the numeric keypad in steam mode a message will appear and the value will be set to the minimum or maximum value after confirming the message with ( www.termo.no...
Page 61
Fig. 35: Display Manual cooking (left) and manual baking without steam injection (right) in continuous operation INFORMATION: When time is entered as 00h:00min:00sec for manual cooking and baking without steam injection, continuous operation ( ) will be set. www.termo.no...
Page 62
If the setting range (24 h) is exceeded, a message will appear and the value will be set to the maximum value (24h:00min:00sec) after confirming the message ( Fig. 36: “Time entry outside the setting range!” 7.1.5 Changing the core temperature Fig. 37: Screen Einstellen/Ändern der Kerntemperatur (Set/Change core temperature) www.termo.no...
Page 63
If the value falls below or exceeds the setting range (20 °C/68 °F to 100 °C/212 °F), a message will appear and the value will be set to the minimum or maximum value after confirmation ( Fig. 38: Note “Core temperature entry outside the setting range” www.termo.no...
Page 64
If a value falls below or exceeds the setting range, a message will appear and the value will be set to the minimum or maximum value after confirmation ( For moisture value: Setting range 1 % to 100 % For humidification value: Setting range 10 ml to 990 ml www.termo.no...
Page 65
MANUAL COOKING / MANUAL BAKING Fig. 40: Note “The moisture/humidification value entered is outside the setting range” 7.1.7 Changing the resting time (Only for manual baking with steam injection) Fig. 41: Screen Set/Change the resting time www.termo.no...
Page 66
Resting time entry outside the setting range! If the setting range (00h:03min:00sec) is exceeded, a message will appear and the value will be set to the maximum value (00h:03min:00sec) after confirming ( Fig. 42: Note “Resting time entry outside the setting range” www.termo.no...
Page 67
Activate fan pulsing at the selected fan speed. Field Vorheizfunktion (Preheat function) Set and activate preheating (10%). Field E/2 (Energiesparen) (energy saving) Set to half energy consumption. ½ Σ Field half-loaded Activate half loading Field SPS® Activate the Steam protection system. www.termo.no...
Page 68
Manuelles Kochen/Manuelles Backen (Manual cooking/manual baking) screen. The Additional Features screen appears. Touching the ON/OFF toggle or step activates/changes an additional function. Confirm your entry with ( ) or close with ( Manuelles Kochen / Manuelles Backen Return to the (Manual cooking/baking) screen. www.termo.no...
Page 69
MANUAL COOKING / MANUAL BAKING Setting/changing the fan speed Fig. 44: Screen Lüftergeschwindigkeit einstellen (Set Fan Speed) Switching fan speed pulsing on/off Fig. 45: Fan speed pulsing set www.termo.no...
Page 70
1-degree steps via ( ) / ( Confirm your entry with ( ) or close with ( Zusatzfunktionen (Additional features) Back to the screen with changed preheating temperature Fig. 47: Screen note “Temperature entry outside the setting range” www.termo.no...
Page 71
300°C/572°F), a message will appear and the value will be set to the minimum or maximum value after confirmation ( Switch E/2 (energy saving function) on/off Fig. 48: Additional function E/2 set Σ½ – half-loaded Fig. 49: Additional half loading function configured www.termo.no...
Page 72
MANUAL COOKING / MANUAL BAKING Switch the SPS® - Steam Protection System on/off Fig. 50: SPS® additional function set Setting/changing the ADC (Active Dehumidification Control) Fig. 51: Setting the screen ADC and dehumidification level www.termo.no...
Page 73
Step overview with one- / three-step programmes Fig. 53: Screen with three-step programme (e.g. screen step Betriebsart (Operating mode) Symbol Designation/function Field Start Starts the programme. Field Delete Deleting a cooking step. Field Duplizieren (Duplicate) Duplicating a cooking step. www.termo.no...
Page 74
Select operating mode for the cooking step Convection/baking without humidification Manual combisteam Manual cooking with steam Manual baking with steam injection Setting value of the cooking step (e.g. temperature) Cooking/baking time of the cooking/baking step Tab. 13: Elements on the Step overview screen www.termo.no...
Page 75
Work procedures deleting cooking step Select the cooking/baking step to be deleted. Delete the step with theGar-/Backschritt Löschen (Delete cooking/backing step) ( ) field. The selected cooking/baking step is deleted. The number of cooking/baking steps is reduced by value 1. www.termo.no...
Page 76
MANUAL COOKING / MANUAL BAKING 7.1.11 Setting the start/end time Sets the start time Fig. 54: Work procedures for screens Setting the Startzeit (Start time) www.termo.no...
Page 77
Endzeit (End time) Symbol Designation/function Field Home Switch to the home screen. Field Zurück (Back) Switch to the last screen display. Field Bestätigen (Confirm) Confirm entry. Field Schließen (Close) Cancel your entry and close the screen view. www.termo.no...
Page 78
After starting the programme, • the start time will be displayed as soon as it is entered. • the end time will be displayed along with the end time and also the remaining time before the programme starts displayed. www.termo.no...
Page 79
The settings for one or several cooking/baking steps are defined. • A maximum of 400 programmes can be stored as a number with up to 20 cooking/ baking steps. Fig. 57: screen with further entries (optional) Programm speichern (Save programme) www.termo.no...
Page 80
Work procedures Saving programme Touch the Speichern (Save) ( ) field. The screen to enter a programme name with the keyboard appears. Entering a programme name using the screen keyboard and confirming with ) changes to the task overview. www.termo.no...
Page 81
Entering the programme name is required. All other entries are optional. Entering programme information Enter additional information using the screen keyboard and confirm with ( Additional information will appear when the programme starts. Fig. 58: Screen Eingabe von Zusatzinformationen (Entering additional information) www.termo.no...
Page 82
Assignment to Menu Group Symbol Designation/function Breakfast Lunch Snacks Dinner Field Bestätigen (Confirm) Confirm your entry and move to the next input screen. Field Schließen (Close) Close entry, go back to last step. Tab. 16: Overview of the menu groups www.termo.no...
Page 83
Meat Fish Pasta Garnishes Vegetables Dessert Regenerating Field Bestätigen (Confirm) Confirm your entry and move to the next input screen. Field Schließen (Close) Close entry, go back to last step. Tab. 17: Overview of the product groups www.termo.no...
Page 84
ProConnect software. They can also be saved on a USB stick and transferred to the device. Assigning and saving programme images Fig. 61: Assigning programme images stored in the appliance www.termo.no...
Page 85
MANUAL COOKING / MANUAL BAKING Fig. 62: Uploading and assigning custom programme images Assigning and saving programme sounds Fig. 63: Assigning programme sounds stored in the appliance www.termo.no...
Page 87
Barcode and product code management A barcode and/or product code can be saved for each cooking/baking programme. This makes it possible for the programmes to be easily recalled by scanning the barcode of an item, or keying in its product code. www.termo.no...
Page 88
Confirm your entry and move to the next input screen. Field Schließen (Close) Close entry, go back to last step. Field Zeichen löschen (Delete characters) The character entry is deleted. Tab. 18: Elements on the screens Entering a barcode/product code www.termo.no...
Page 89
Programm speichern (Save programme) in the screen, call up the programme and continue with ( The screen for entering the ID number appears. Enter an ID no. Confirm your entry with ( close with ( Save programmes Return to the screen. www.termo.no...
Page 90
Often used cooking/baking programmes can be marked as favourites. These are then displayed in alphabetical order via the <Favoriten (Favourites)> home screen. The desired programme can be found and called up by scrolling through or searching it. Fig. 67: Screens Adding a programme to favourites www.termo.no...
Page 91
INFORMATION: Programm speichern (Saving programmes) All entries into the screen will only take effect after confirmation on the screen. Fig. 68: Finish saving the programme and return to the Manuelles Kochen/Manuelles Backen (Manual cooking/baking) screen, Saved programme www.termo.no...
Starting manual settings in the screen (left) or Manuelles Backen (Manual Baking) screen (right) Schrittübersicht (Step Overview) Manuelles Start the manual cooking/baking programme in the Kochen/Manuelles Backen (Manual cooking/baking) or Schrittübersicht (Step Overview) screen by touching the Start ( ) field. www.termo.no...
Page 93
Fig. 72: Screen to stop the running programme Nachfrage (Request) INFORMATION: Additional features (e.g. preheating) must be selected before starting the programme. The symbol of the additional function appears on the progress line of the screen. www.termo.no...
Page 94
Field Anzeige der aktuellen Ist-Temperatur (Display of the current actual temperature) Field Manuelle Befeuchtung / Beschwadung (Manual humidification/steam injection) Briefly humidify/steam inject the cooking chamber manually by selection. Field Back-/Garzeitverlängerung (Additional Baking/cooking time) Extend cooking time by selecting appropriate setting (setting: 1 min). www.termo.no...
Page 95
Field Start Vorheizen (Start preheating) Start preheating. Field Stopp Vorheizen (Stop preheating) Stop preheating. Tab. 19: Elements of the Ongoing operation screen 8.1.3 Preheat Fig. 73: Screen Preheating running (left) and End preheating (right) Fig. 74: Cooling to preheat temperature screen www.termo.no...
Page 96
Additional parameter setting under Service/Settings: Manual Temp and Active Temp. • Manual Temp: low energy consumption (fan), needs however to be supported by the user. • Active Temp: quick, but consumes additional water and energy. Default setting: Auto Temp (automatic, without water consumption) www.termo.no...
Page 97
Extending the cooking time Fig. 76: Display before and after additional cooking time INFORMATION: • The cooking/baking time of the last programme step is extended in one- minute steps by default. • The cooking/baking time can be extended. www.termo.no...
Page 98
ONGOING OPERATION OF THE COOKING AND BAKING PROCESS 8.1.5 Changing settings for manual cooking/baking Fig. 77: Changing settings during operation INFORMATION: During operation, only settings for a cooking/baking step which is currently active has not yet been started, can be changed. www.termo.no...
Page 99
Confirm your entry with ( ). The current programme is continued with the changed values. INFORMATION: Without confirmation of the changes and without further activity, the programme will continue to run without any changes after a short time. www.termo.no...
Page 100
The actual values appear for a short time. Touch the actual core temperature ( ) field. The core temperature is displayed. 8.1.7 Continuous operation Fig. 79: Screen (left) and Start Laufender Betrieb des Garprogramms (Ongoing operation (right) in continuous mode of the cooking programme) www.termo.no...
Page 101
When you close ( ), the programme continues to run. Manuelles Kochen / Manuelles Backen (Manual When you confirm ( ), the cooking/baking) screen will appear. Open the door, allow any steam to escape. Remove the cooked/baked product as necessary. www.termo.no...
Page 102
End of the expired cooking/baking programme without restarting INFORMATION: The cooking/baking programme ends when – the time of the last step has elapsed. – The target core temperature of the last cooking/baking step has been achieved. – green progress bar is complete. www.termo.no...
Page 103
ONGOING OPERATION OF THE COOKING AND BAKING PROCESS 8.1.9 Re-starting/repeating the programme Fig. 82: Repeating/restarting the same programme Working steps Load the appliance with the same food. Touch the Neustart (New Start) ( ) field to start the same programme. Remove any finished food when finished. www.termo.no...
INFORMATION: Only the last 20 selected cooking/baking programmes are displayed in chronological order (last programme first) as a list. Fig. 83: Start screen with the Last® 20 tile (left) and Last® 20 list after selecting the tile (right) www.termo.no...
Page 105
− Symbol Steam operating mode (one-step - multi-step) − Symbol for operating mode baking with steam injection (single-step - multi-step) − Programme symbol (manual cooking / manual baking - multi-stage) Field Programme Options By selecting it, the operator opens another screen with the functions: www.termo.no...
Page 106
Touch the Ändern (Change) ( ) field or Programmdetails (Programme details) ( ) field. Touching the Schließen (Close) ( ) field discards the changes and returns to the jump screen. (for all others see below) Starts the programme with ( www.termo.no...
Page 107
Programmoptionen (Programme options) Symbol Designation/function Field Ändern (Change) Change programmes. Field Display/Change (other) programme details Display and change further details/functions. Field Schließen (Close) Close the Programme Information screen. programme options Tab. 421: Elements of the screen www.termo.no...
Page 108
Programmes can also be overwritten or saved as a copy under a new name. 9.1.3 Display/Change Programme Details Fig. 87: Display/Change Programme Details www.termo.no...
Page 109
Switch to the screen. Field Startzeit (Start time) Sets the start time. Field Endzeit (End time) Sets the end time. Field Home Switch to the home screen. Field Zurück (Back) Switch to the last screen display. www.termo.no...
Page 110
Wochenprogrammierungen (Weekly programming cycles) 9.1.4 Programmstart (Programme start) Working steps Touch the Start ( ) field to start the programme from the Last®20 overview. Zusatzinformationen (Additional Information) screen appears. Touch the Schließen (Close) ( ) field. laufender Betrieb (Ongoing operation) screen appears. www.termo.no...
– Displaying and filtering one or more menu groups – Displaying and filtering product and menu groups. Select - favourites – Only the cooking / baking programmes saved as favourites are displayed in alphabetical order as a list. www.termo.no...
Page 112
Switch to the Manual cooking/Manual baking settings screen. Field Start Starts the programme. Field Home Switch to the home screen. Field Zurück (Back) “ Switch to the last screen display. Tab. 22: Elements of the programme list/favourites screen www.termo.no...
Page 113
Programmliste Last Favoriten (Last favourites programme list) to the screen. (for all others see below) Starts the programme with ( Fig. 89: Screen Programmliste ohne Filter (Programme list without filter) Fig. 90: Screens (left) or (right) Programme list with filter Menu group filter Product group www.termo.no...
Touch the Change field ( ) or Details field ( Touching the Schließen (Close) ( ) field discards the changes and returns Übersicht Programmliste (Programme list overview) to the screen. (for all others see below) Starts the programme with ( www.termo.no...
Page 115
(Display/change settings of saved favourites for cooking) Backen (right) (baking) Einstellungen Garen/Backen (Settings for cooking/baking) screen for the programme appears and all values and additional features for all programme steps can be changed. Programmes can be overwritten or saved under a new name. www.termo.no...
Page 116
Go to the Weekly programming PRO screen and edit. Field Multi Cooking PRO Switch to the Multi Cooking PRO screen and edit. Field Start Starts the programme. Field Vorheizen (Preheating) Set preheating. Field Start-/Endzeit (Start/end time) www.termo.no...
Page 117
Details Entries can be made directly into the screen for – Start/end time – Preheat – Weekly programming PRO – Multi Cooking PRO/ Multi Baking PRO Wochenprogrammierungen (Weekly programming cycles) www.termo.no...
Today / this week / all Filter by time range for the weekly programme display. Display field Programme image Display field Programme name with menu Fried mushrooms group Display field Weekday and time of Tuesday 16:50 programme start www.termo.no...
Page 119
Confirm entry. Field Schließen (Close) (for data entry) Cancel your entry and close the screen. Field Zeile aufrufen (Call up line) Übersicht Wochenprogrammierung PRO (Overview of weekly Tab. 24: Elements of the screens programming PRO) Programm and add www.termo.no...
The start view is the current day (today), by selecting the appropriate fields you can switch to the current week or any other ones. 11.1 Adding a programme Fig. 97: Screen (left) and Selection screen Add weekly programme Add cooking/baking (right) programme from programme list or Cleaning programme www.termo.no...
Page 121
)or Set End Time line ( und/or lines Wiederholung (Repeat) ( Confirm your entry with ( ) or close with ( Weekly programme appears with day and start/end time in the Weekly programming PRO overview. Weekly programmes start automatically. www.termo.no...
Page 122
Setting the start/end time for weekly programming PRO Fig. 99: Start time setting for weekly programme from programme list (left) and end time setting for autoclean® weekly cleaning programme (right) Fig. 100: Setting day and time for the start/end time www.termo.no...
Page 123
The next weekly programme to be started is displayed on the stand-by screen. The stored weekly programmes will be started in the agreed periods until they are deleted. Fig. 101: Programme repeat selection screen on the left and Weekly programming PRO display (right) www.termo.no...
Page 124
Touch the line Wiederholungszeitraum (Repeat period). The overview of the current month with the suggested days (green) appears. Touch ( ) to switch to the months. Select a day. Confirm your entry with ( ) or close with ( www.termo.no...
(today, this week or all). Weekly programmes start automatically. 11.2 Changing programme Fig. 104: Wochenprogrammierung PRO ändern für Programmliste (Change Weekly screen Programming PRO for Programme List) Fig. 105: Wochenprogrammierung PRO ändern für autoclean® (Change Weekly screen Programming PRO for autoclean®) www.termo.no...
Page 126
Active Temp and drying for cleaning programmes – Start/end time – Repetition options Touch the line to be changed. Confirm your entry with ( Weekly programme appears with day and start/end time in the Weekly programming PRO overview. Weekly programmes start automatically. www.termo.no...
Confirm your entry with ( Wochenprogramm löschen? (Delete weekly The screen with the query: programme?) appears. Confirm your entry with ( ) or close with ( The weekly programme is only deleted from the Weekly programming PRO overviewed if confirmed. www.termo.no...
Multi Cooking PRO/Multi Baking PRO is called up by touching field ( ) on the start screen. Fig. 107: Screen before Selection of all Multi Cooking PRO/Multi Baking PRO programmes (left) and after (right) selection of a master programme www.termo.no...
Page 129
Display field Operating mode Active operating mode is displayed (e.g. convection) Temperature display The selected cooking chamber temperature is displayed (e.g. 210 °C). Humidity display The selected humidity in the cooking chamber is displayed (e.g. 0%). www.termo.no...
Page 130
PRO/Multi Baking PRO. Field Vorheizen (Preheating) Activate preheating (default 10%). Field Start-/Endzeit (Start/end time) Sets the start time. Sets the end time. Field Save Multi Cooking PRO/Multi Baking PRO Save Multi Cooking/Multi Baking PRO settings/ programme(s). www.termo.no...
Page 131
Display field Cooking/baking time 00:25:00 The cooking/baking time for each programme is displayed. Display Baking/cooking programme Big muffins name Display Assigned menu/product ITEMS TO BE BAKED group Auswahl (Selection) Start Multi Cooking PRO/Multi Baking Tab. 25: Elements of screens www.termo.no...
Multi Cooking PRO/Baking PRO programmes start automatically according to the specified start/end time. 12.2 Add cooking/baking programme INFORMATION: Cooking / baking programmes can be added from • Last® 20 • Programme list • Favourites to Multi Cooking PRO/Multi Baking PRO. www.termo.no...
Page 133
MULTI COOKING PRO/MULTI BAKING PRO Fig. 109: Work procedures Add a programme to Multi Cooking PRO/Multi Baking PRO (example Last® 20) www.termo.no...
Page 134
10. Touch field Multi Cooking PRO / Multi Baking PRO ( ). Select the Start field. Multi Cooking PRO/Multi Baking PRO programmes start immediately without a start/end time. Multi Cooking PRO/Multi Baking PRO programmes start automatically according to the specified start/end time. www.termo.no...
Page 135
Multi Cooking PRO programmes appears. Touch the Select insertion level field ( Level list 1 to 5 or 6 appears. Select an insertion level via the numeric keypad or keys (+/-). The insertion level appears with a number in the programme list. www.termo.no...
A start/end time cannot be set during operation. 12.3.2 Deleting the Multi Cooking PRO programme Fig. 111: Work procedures Save programme Select Löschen (Delete) ( ) in the programme line to be deleted. The programme line has been deleted. www.termo.no...
Page 137
12.3.3 Duplicating Multi Cooking PRO programme Fig. 112: Work procedures Duplicate programme Select the field Duplizieren (Duplicate) ( ) in the programme line to be duplicated. The cooking programme with the same settings is entered at the end of the list. www.termo.no...
When programmes are started, refer to the length of the progress bar (green) and the remaining time for information about the progress. 12.4.2 Start with preset time Fig. 114: with start time (left) and end time Start Multi Cooking PRO/Multi Baking PRO (right) www.termo.no...
Page 139
When the end time is preset, the time until the start of the first programme and the end time of Multi Cooking PRO/Multi Baking PRO are displayed. When programmes are automatically started, refer to the length of the progress bar (green) and the remaining time for information about the progress. www.termo.no...
Page 140
The screen programmes) appears. Markieren (Select) ( ) the desired programme () and bestätigen (Confirm) ( Liste laufender Programme (List of running programmes) The screen displayed. Programme is added, placed at the end of the list and started immediately. www.termo.no...
Page 141
Programme is terminated and programme line is deleted. 12.4.4 Multi cooking PRO/multi baking PRO - End and terminating early Programme end Fig. 117: Display of immediate programme end (1), display of remaining time for other programmes (2 and 3) www.termo.no...
Page 142
Programme lines of expired programmes (red and green) are deleted from the screen. If necessary, add/duplicate programme for new the items to be cooked/baked. When all Multi Cooking PRO/Baking PRO programmes have finished and the Start Multi Cooking PRO/Baking food has been removed, the screen appears again. www.termo.no...
Page 143
) field during operation. „Nachfrage bei vorzeitigem Programmabbruch“ (“Request for The screen early programme end”) appears. Confirm your entry with ( ) or close with ( Start Multi Cooking PRO/Baking screen appears when confirmed. Laufender Betrieb (Ongoing operation) Screen being Schließen (Closed). www.termo.no...
Possible for all appliance. Fig. 121: Screens Auswahl Niedertemperaturgaren (Low temperature cooking selection) Betriebsart (Operating mode) Fig. 122: Screens Voreinstellungen und Schrittübersicht mit Sonderprogramm (Presettings (e.g. steam operating mode) and step overview with special programme) www.termo.no...
Page 146
1% steps using the +/- fields. Confirm your entry with ( ) or close with ( If necessary, edit additional features and programme steps. Switch to the Schrittübersicht (Step overview) screen ( ). Start the special low temperature cooking programme with ( www.termo.no...
Page 147
The cooking step ends as soon as the temperature reaches the set target core temperature. Fig. 123: Screens Auswahl Delta-T-Garen (Delta-T cooking) Operating mode Fig. 124: Screens Voreinstellungen und Schrittübersicht mit Sonderprogramm (Presettings (e.g. steam operating mode) and step overview with special programme) www.termo.no...
Page 148
1% steps via +/-. Confirm your entry with ( ) or close with ( If necessary, edit additional features and programme steps; switch to the Schrittübersicht (Step overview) ) screen. Start special programme Delta-T cooking with ( www.termo.no...
Page 149
13.2.3 Regenerating INFORMATION: Regeneration can be used to reheat fully cooked foods gently after they have cooled. Fig. 125: Screens Regeneration selection Fig. 126: Screen Voreinstellungen Regenerieren für Bankett, Chargen und Teller (Regeneration settings for banquet, batches and plates) www.termo.no...
Page 150
1 h, 1 min or 10 sec via +/-. Confirm your entry with ( ) or close with ( If necessary, edit additional features and programme steps; switch to the Schrittübersicht (Step overview) screen ( ). Start the Regenerate special programme with ( www.termo.no...
Fitting for the core use a cloth and mild temperature probe detergent. Monthly External surfaces of Degreasing cleaning the unit agent or stainless steel cleaner, soft cloth. Tab. 28: Overview Cleaning intervals (manual cleaning and semi-automatic cleaning) www.termo.no...
Setting the start/end time. Closing the door Instruction Close the door. Open the door Instruction Open the door. Field Trocknungsphase (Drying phase) Select the drying phase. Hand shower Instruction Rinse the cooking/baking chamber with a hand shower. www.termo.no...
Page 153
Programme time Display of the total time of the cleaning programme. Home Switch to the home screen. Back Switch to the last screen. Cleaning and care Tab. 29: Elements of the screen (incl. autoclean®) www.termo.no...
Do not use any aggressive scouring agent or scratchy cleaning utensils (e.g. steel wool). 14.3 Manual cleaning of the cooking chamber CAUTION! Risk of burns from hot surfaces! Skin burns. Allow the device to cool down before cleaning. www.termo.no...
Damaged door seals need to be replaced immediately. Requirement • The device has been switched off. • The device has cooled down. Clean the door seal with a cloth and mild degreasing cleaning agent by hand. Remove the cleaning agent with clear water. www.termo.no...
14.5 Semi-automatic cleaning INFORMATION: Semi-automatic cleaning can only be used in the Backmaster Edition! Select the Cleaning and Care ( ) field on the home screen to start the cleaning and maintenance programme. www.termo.no...
Page 157
10. Rinse out the cooking chamber with the hand shower. Close the door. Drying phase ( ) starts to dry the cooking chamber (if selected). Press the Stop ( ) field. Cleaning and care The Start screen appears. Open the door and bring it into the locked position. www.termo.no...
The programme will automatically start immediately without settings, or according to the selected start and end times or weekly programming PRO. After the cleaning programme has finished, press the Stop field ( Cleaning & Care screen appears. The ‘Cleaning complete’ notification will appear. www.termo.no...
Page 159
Medium (normal) soiling from preparation of steamed vegetables, meat products, baked 01:05:00 h goods or fish and occasional preparation of roast or grilled products Standard/Level 3 Medium to heavy soiling from preparation of steamed vegetables, meat products, baked 01:34:00 h www.termo.no...
Page 160
00:03:00 h the first time, in order to fill the suction hoses Warm rinsing For light soiling or between cooking procedures during the daily routine 00:12:00 h Tab. 30: Cleaning and care programmes list www.termo.no...
• Direct Mode manual 15.1.1 Setting QuickMode INFORMATION: QuickMode can be set or changed in Settings/Service under – Customisation (user configuration) – Parameters in parameter 121. QuickMode is accessed by touching ( ) on the start screen. www.termo.no...
Page 164
QUICKMODE Fig. 131: Auswahl QuickMode über Individualisierung (Select QuickMode through customisation) screen Fig. 132: Screen Arbeitsschritte Einstellen QuickMode über Individualisierung (Work procedures for Setting QuickMode via customisation) www.termo.no...
Page 165
Last® 20 ( • Programme list ( • Cleaning & Care ( • Setting & Service ( 15.1.5 QuickMode Product Group QuickMode Product Group screen contains the following start icons: • Display of the product group(s) – Baked items ( www.termo.no...
DirectMode is a practical tool that allows the user to quickly assign e.g. one-step cooking/baking programmes with similar settings to Multi Cooking PRO/Multi Baking PRO via barcode scanning or numerical codes (Direct Mode ID No.). Programmes with different settings are ignored. Multi-step programmes can also be assigned. www.termo.no...
Page 167
DirectMode can be set and changed in Settings/Service under • Customisation (user configuration) • Parameters in parameter 121. start screen QuickMode is accessed by touching field ( ) on the Fig. 133: Auswahl DirectMode über Individualisierung (Select DirectMode through screen customisation) www.termo.no...
Page 168
Touch the line for the desired mode. The line appears in light grey. Touch ( ) and confirm your selection. Parameter The Changed Mode screen appears. Return to the previous or start screen by touching ( ) or ( www.termo.no...
Page 169
QUICKMODE Fig. 135: Screens Activate scanner (Customisation Parameters INFORMATION: For DirectMode, the parameter 126 Scanner activated must be set to ON in Settings and Service. www.termo.no...
Page 170
4 to 8 characters in Settings and Service under Customisation, or under Parameters, parameter 122 DirectMode ID length. Fig. 136: Change ID character length screens Fig. 137: Note "ID character length outside the setting range" www.termo.no...
Page 171
Cleaning & Care ( • Setting & Service ( 15.2.3 Direct Mode Direct Mode screen gives the user access to the following startup functions: • Barcode/product code entry ( • Cleaning & Care ( • Setting & Service ( www.termo.no...
Switch to Screen Allgemeine Einstellungen (General Settings) Line Protocols Switch to the Protocols screen Line Settings and Service Switch to processing for settings and service (password release is necessary!) Tab. 31: Elements of the Settings/Service screen without password release www.termo.no...
Page 173
Switch to the Protocols screen Line Upload download manager Switch to Upload/Download Manager Line Sound Manager Switch to Sound Manager Line Customization Switch to customization Line cleaning and water treatment Switch to the setting for cleaning and water treatment www.termo.no...
Line Time zone Switch to set/change timezone. Language Line Language Switch to set/change language. Automatic daylight saving field Automatic switching between standard time and daylight saving Switch to set the automatic time summer/winter time. Keypad Line Keyboard www.termo.no...
Page 175
Switch to set/change the home screen. Password manager Line Password manager Switch to password management. Restart startup command Line Restart startup command Perform startup after restarting the appliance. Tab. 33: Elements of the General Settings screen (depending on password access) www.termo.no...
Page 176
SETTINGS AND SERVICE 16.1.1 Change date/time, time zone and summer/winter time Date/time and time zone Fig. 142: Enter/change date and time Fig. 143: Confirm/change the time zone www.termo.no...
Page 177
General Settings Select the line Automatic summer/winter time in with setting the automatic summer/winter time The screen for appears. Select Automatic summer/winter time ON/OFF and confirm with ( ) or close with ( Allgemeine Einstellungen (General Settings) screen appears. www.termo.no...
Page 178
16.1.3 Select/load programme list INFORMATION: The following sources are possible for the programme list: – Programme list(s), provided by Eloma – Preinstalled programme list(s) of the appliance – Programme list(s) from the user, loaded via USB stick www.termo.no...
Page 179
SETTINGS AND SERVICE Fig. 146: Screen sequence Change/load programme lists www.termo.no...
Page 180
Allgemeine Einstellungen (General Settings) Open the Modus line in the screen with ( Einstellen Modus (Setting mode) screen is displayed. dark bright Mark the mode and confirm/cancel with( ) / ( Allgemeine Einstellungen (General Settings) screen appears in the selected appearance mode. www.termo.no...
Page 181
Allgemeinen Einstellungen Select the Stand-by Zeit (Stand-by time) line in (General settings) with Pause Time Selection screen is displayed. Select the pause time and confirm with ( ) or close with ( Allgemeine Einstellungen (General Settings) screen appears. www.termo.no...
Page 182
Fig. 149: Selecting the Startbildschirm (Home screen) via function fields Fig. 150: Selecting the via function fields with direct Startbildschirm (Home screen) programme access www.termo.no...
Page 183
Password entry with hidden (left) and open character display (right) NOTICE! To switch from hidden to open character display, use the field (***/ABC) on the left, above. Passwords Password device settings (manufacturer): "1234" Operating and security settings: “asdf” www.termo.no...
Page 184
The password prompt for the operating and security settings appears. Enter the current password and confirm with ( Allgemeine Einstellungen (General Settings) screen appears. Parameters and settings can be changed. INFORMATION: It is recommended to use different passwords for the different access levels. www.termo.no...
Page 185
Select the Restart Startup line in with ( query screen appears. Confirm your entry with ( ) or close with ( After confirmation, startup will take place after the appliance has been restarted. Allgemeine Einstellungen (General Settings) screen appears. www.termo.no...
Shows the occurring fault messages and warnings and sorts them in order of occurrence. Operating data Shows operating and consumption data. Data Copy to USB • all data • Data of the last 7 days Tab. 34: Overview of possible protocol types www.termo.no...
Page 187
Protocol View Symbol Designation/function Friday Day of the week 2019-11-29 Date HACCP report Protocol type Download Field Download from USB stick Download last 7 days Field Download from USB stick Protokolle (Protocols) Tab. 35: Elements of the screen www.termo.no...
Page 188
Select the line of the protocol type (e.g. HACCP) ( List of the last 30 days appears. Select line(s) of the day(s) ( List of programmes for that day(s) appears. Plug the USB stick into the device socket. Download the protocol(s). protocol List When finished, the screen appears. www.termo.no...
List of all parameters appears. Scroll to the desired parameter line and select it. Parameter list or numeric prompt appears. Select a line or enter numerical value (+/- or keyboard), and confirm with ) or close with ( Individualisierung (Customisation) screen appears. www.termo.no...
Page 190
Light mode II always off: The cooking chamber compartment lighting switches off after closing the door. 016: Flashing at the end Activate/deactivate with Activated: The light flashes of cooking at cooking end. Deactivated: The light does Default: Deactivated not flash at cooking end. www.termo.no...
Page 191
035: Programme end To mark the end of a tone duration programme, a sound will be EndProgram heard for a certain time. The EndStep user can select a sound KeepWarm from a number of different ReachPreheat tones. StartCombiProgram Default: EndProgram www.termo.no...
Page 192
Default: 5 s time can be set. EndCombiProgram 045: Multi Cooking PRO This sound will be heard Start Ton when the user is scheduled EndProgram to add the next product to EndStep the appliance. KeepWarm ReachPreheat StartCombiProgram Default: StartCombiProgram www.termo.no...
Page 193
10 that is heard at the beginning of the Cook&Hold Default: 5 special programme can be adjusted. from 0 s to 999 s 057: Keep warm sound The playback time of the duration sound is adjustable. Default: 3 s www.termo.no...
Page 195
Default: Deactivated Activated: --:-- Deactivated: ∞ 120: Steam injection in Activate/deactivate with Steam injection can be time controlled by quantity (ml) or by duration (s). Default: Deactivated Activated: Steam injection in time Deactivated: Steam injection in quantity www.termo.no...
Page 196
1 s to 300 s This parameter defines after how many seconds from the Default: 30 s start of the programme the core temperature is measured in order to avoid incorrect measurements if the core temperature probe is too high. www.termo.no...
Page 197
Activate/deactivate with For multi-step extension in last step cooking/baking only programmes, the field Default: Deactivated additional cooking time can only be activated in the last step. Activated: only in the last step Deactivated: additional cooking time possible at each step www.termo.no...
Page 198
Default: Deactivated or not preheating is performed again when restarting the programme. Deactivated: Preheating is performed when the programme is restarted Activated: Preheating is not performed again when the programme is restarted. www.termo.no...
Page 199
This parameter specifies how many seconds should be added per door opening. 159: Hiding the menu Activate/deactivate with The menu groups in the groups programme list can be hidden. Default: Deactivated www.termo.no...
Page 200
168: Block cooking time 00:00 - 23:00 Time of blocking cooking the day after the cleaning Default: 02:00 interval was triggered Enter temperature value 171: Standby Defines the temperature temperature which is held when working in standby temperature mode. www.termo.no...
Page 201
Default: Change, Details 250: Light on during Activate/deactivate with Activate or deactivate light cleaning during cleaning Default: Off 251: Display remaining Activate/deactivate with Activate or deactivate cooking time display of remaining cooking time Default: On Tab. 36: Parameter list www.termo.no...
Use the Upload/Download Manager to upload/download from/to the device • Cooking / baking programmes and programme lists • Appliance and product images • Operating and signal sounds • Customer backups and software backups have been transferred. Fig. 158: Selection screen Upload/DownloadManager Fig. 159: Screens Download/Upload Back/cooking programmes www.termo.no...
Page 203
Screen Customer Backup and Backup Symbol Designation/function Device (green when active) USB stick (green when active) Field Download Download from USB stick Field Upload Upload to USB stick Check All field Select all. Field Deactivate all www.termo.no...
Page 204
) or single ( ) files and call up Upload ( ) /Download ( ), then start data transfer. When the transfer is complete, the files are added to the screen. INFORMATION: If data transmission was interrupted, a warning appears! www.termo.no...
With the Sound Manager, certain events can be assigned specific tones with time duration and volume, as well as their triggering times. Fig. 162: Screen Selection List Sound Manager Fig. 163: Screens (left) and (right) Event selection Setting/changing sound duration www.termo.no...
This helps to save energy and resources. By specifying the cleaning and filter change intervals with reminder messages, device necessary hygiene and gentle handling can be ensured. Fig. 165: Selection screen Cleaning and water treatment www.termo.no...
Page 207
16.6.2 Cleaning manager Fig. 167: Screen Cleaning Manager By selecting the parameters of the Cleaning Manager, the fill level monitoring and the container sizes for the Cleaner PRO and the Rinse Aid can be defined. www.termo.no...
Page 208
16.6.4 Starting up the cleaning programme INFORMATION: Cleaning programme Always start up the cleaning programme upon initial installation and after changing the liquid detergent canister. Fig. 169: Screens Cleaning start-up progress bar display www.termo.no...
Page 209
Cleaning Progress screen will appear and time will count down to 00:00:00. When the programme ends, confirm the Stop field ( The confirmation screen appears. Confirm your entry with ( ) or close with ( The Cleaning and Care screen is displayed. www.termo.no...
Replace the door seal. Water dripping The door seal is worn or from the device damaged. door Switch off measuring mode. Unit does not Measuring mode is heat switched on. Tab. 38: Description of faults, possible causes and measures www.termo.no...
The core temperature partner. probe is faulty. The combi steamer can only be operated with restrictions. Contact an Eloma service 117 / 127 The probe for steam partner. damping is faulty. The combi steamer can not be operated. www.termo.no...
Page 213
The device can only be operating mode. operated with restrictions. Contact an Eloma service 511– 513 Overheating of partner. electrical components. Re-start gas system 1. Tab. 39: Description of fault messages, possible cause and measures www.termo.no...
The container sizes can be set and the fill level monitoring can be activated via the fill level monitor. The connections for Eloma liquid detergent PRO (black) and Eloma rinse aid (blue) are marked on the appliance Fig. 172: Selection screen Canister change Replacement inquiry Requirement • The device has been switched off. www.termo.no...
Level indicator for liquid detergent/rinse aid is set to 100%. INFORMATION: Cleaning programme Always start commissioning after changing the liquid detergent canister. 18.2 Water treatment Fig. 173: Water treatment selection screen Requirement • The device has been switched off. www.termo.no...
Wasseraufbereitung (water treatment) Return with field 18.3 Starting up the cleaning programme INFORMATION: Cleaning programme Always start up the cleaning programme upon initial installation and after changing the liquid detergent canister. Fig. 174: Screens Cleaning start-up progress bar display www.termo.no...
Page 217
Cleaning Progress screen will appear and time will count down to 00:00:00. At the end of the programme ( ) confirm. confirmation screen appears. Confirm your entry with ( ) or close with ( The Cleaning and Care screen is displayed. www.termo.no...
• Name, address, telephone of the disposal company • Product types which are accepted. • Opening times/business hours of the disposal company • Information on free return options Our customer service is at your disposal for further questions. www.termo.no...
Page 219
DISPOSAL AND ENVIRONMENTAL PROTECTION Notizen www.termo.no...
Page 220
WE AT ELOMA WILL BE HAPPY TO HELP YOU WITH ANY QUESTION RELATING TO OUR PRODUCTS CUSTOMER SERVICE ____________ T. +47 701 97 500 termo@termo.no TECHNICAL SERVICE ____________ T. +47 901 97 522 teknisk@termo.no _____________ Eloma GmbH An ALI Group Company...
Need help?
Do you have a question about the GENIUS MT and is the answer not in the manual?
Questions and answers