Installation and Assembly (Not Provided) ------------------------------ Page 2 Preparing HPF Ring for Installation ----------------------------------------- Step 1 Placement of Ring on JD360 ----------------------------------------------------- Step 2 Drilling Holes for Ring Mounting Hardware ----------------------------- Step 3 Securing Ring to Fan ----------------------------------------------------------------- Step 4...
Placement of Ring on JD360: JD360 must not be installed/suspended during installation process. • Place ring on the JD360 destratifier deflector Preparing HPF Ring for Installation: • Center ring • With the tube connector facing up, install the (4) Nylon Loop Clamps, evenly spaced and with...
Drilling Holes for Ring Mounting Hardware: Securing Ring to Fan: • Using a Drill with a 1/8” Drill Bit and the mounting holes in the Nylon Loop Clamps • Insert (4) Nylon Push-in Ribbed Shank Rivets through Nylon Loop Clamps and into holes (installed in Step 1) as your guides, drill 4 corresponding mounting holes, as shown below.
Installing High Pressure Fog Nozzles: Connecting the Ring to Your HPF System: • Using your fingers, screw in and tighten the (8) Anti-Drip High Pressure Nozzles into the • Slip lock connectors requires the nylon tube be cut straight, cleanly, and without crimping or nozzle ports.
Maintenance Instructions: End of Season & Winterizing: • Check for plugged nozzles. WARNING: Do not remove nozzles or plugs while system is running. WARNING: Do not remove nozzles or plugs while system is running. Nozzles End of Season Care • Disassemble the nozzle/s as shown below. •...