Download Print this page
General Components GC0653 Quick Start Manual

General Components GC0653 Quick Start Manual

Digital timer for air heaters

Advertisement

Quick Links

QUICK START
GC0653
DIGITAL TIMER
FOR AIR HEATERS
1. LCD DISPLAY LAYOUT
Scheduled Programs
Timer LCD is comprised
of several distinct
segments, such as
Menu Options, Day of
Week, Scheduled
Programs and Time &
Value field.
Day of Week
2. SETTING TIME AND DAY OF WEEK
Using [<] and [>] keys, navigate
to Clock Icon and press Ok.
Days of Week segment lights up.
Select current day using
[<] and [>] keys and press Ok.
Hours segment begins to flash.
Set hour (military time, 0-23) using
[<] and [>] keys and press Ok.
Minutes segment begins to flash.
Set minutes using
[<] and [>] keys and press Ok.
Day of week and time
are now set.
3. MANUAL VENTIALTION MODE
GUIDE
Using [<] and [>] keys, navigate to
Ventilation Mode started.
Select fan intensity between 01
and 07 using [<] and [>] keys
Menu Options
Press Power Button to exit
Fan will ramp down and stop.
Time & Value
4. MANUAL HEAT MODE
Using [<] and [>] keys, navigate to
Select heat intensity between 01
and 07 using [<] and [>] keys
Press Power Button to exit
Heater will cool down and stop.
Please note, it takes approx. 2-3
minutes for the heater to start
heating or to come to a full stop.
Fan Icon and press Ok.
ventilation mode.
Heat Icon and press Ok.
Heating Mode started.
manual heating mode.
5. SWITCHING BETWEEN SETPOINT
AND VARIABLE HEAT MODES
While in heat mode, press and
hold Ok button for 3 seconds to
toggle between Variable Heat
and
Setpoint
(thermostatic)
modes.
In Setpoint Mode, heater will
maintain
preset
ambient
temperature (between 5°C and
35°C) based on the reading of
internal or external temperature
sensors.
In Variable Heat Mode, heater
will continuously produce heat
based on the setting 01 – 07,
which translates into 0.5Kw – full
capacity (2, 4 or 5Kw, depending
on model).
6. HIGH ELEVATION MODE
When heater is used at elevations between
1500m and 4000m above sea level, heater
should be operated in High Elevation Mode to
make sure enough oxygen is provided for
efficient combustion of fuel.
To toggle High Elevation Mode, press [<]
and Ok buttons simultaneously while in heating
mode. This works in both Setpoint and Variable
Heat modes.
It is not recommended using the heater at
more than 4000m above sea level.

Advertisement

loading

Summary of Contents for General Components GC0653

  • Page 1 3. MANUAL VENTIALTION MODE 5. SWITCHING BETWEEN SETPOINT GUIDE AND VARIABLE HEAT MODES While in heat mode, press and GC0653 hold Ok button for 3 seconds to Using [<] and [>] keys, navigate to toggle between Variable Heat Fan Icon and press Ok.
  • Page 2 7. SETTING SCHEDULED OPERATION 8. FUEL LINE PRIMING 9. READING AND CLEARING ERRORS Digital timer allows you to read This function enables fuel pump for a and clear six most recent faults short period of time to help get rid of air inside the Using [<] and [>] keys, navigate stored in heater’s ECU.
  • Page 3 11. °C/°F AND LANGUAGE Using [<] and [>] keys, navigate to Clock Icon and press [<] and [>] keys simultaneously. press Ok. press Ok. Select “on” for option “00”. Option “01” switches between Celsius (“on”) and Fahrenheit (“of”) Option “02” switches language: “on”...