MSN01-02-03
Gruppi di continuità monofase
BATTERY BOX
INSTALLAZIONE

Advertisement

loading
Need help?

Need help?

Do you have a question about the MSN01-02-03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for K-Factor MSN01-02-03

  • Page 1 MSN01-02-03 Gruppi di continuità monofase BATTERY BOX INSTALLAZIONE...
  • Page 2 INSTALLAZIONE CABINET BATTERIE x UPS MSN Ver. 00 – 07.02.2019 GUIDA RAPIDA 1) Place the UPS and BATTERY CABINET close to each other. Posizionare UPS e box batterie fianco a fianco CABINET BATTERIE BBT12U Ver.00 07 Febbraio 2019...
  • Page 3 2) Feed the UPS with the supplied cable and the BATTERY CABINET if is present the plug on the back Alimentare l’UPS con il cavo di alimentazione fornito e il box batterie con il cavo di alimentazione fornito se la spina a pannello è...
  • Page 4 4) Connect the UPS and BATTERY CABINET with special black/red cable. WARNING: Voltage present on the terminal Collegare UPS e box batterie con lo speciale cavo rosso/nero fornito. Attenzione: una tensione continua è presente sul terminale!!! 5) Turn ON the UPS. Accendere l’UPS Ver.00 07 Febbraio 2019...
  • Page 5 INSTALLAZIONE CABINET BATTERIE x UPS MSN 1 Introduzione La serie di armadi batterie per UPS MSN è stata progettata per fornire protezione della potenza di qualità a prezzi eccezionali. I box batterie esterni sono stati progettati con alloggiamenti di batterie rimuovibili e carica batterie singoli per ottenere la massima efficienza.
  • Page 6 ATTENZIONE: solo personale qualificato può effettuare l’installazione e la messa in servizio di questi battery pack. Nota: ogni UPS ha differenti tensioni DC e ogni ups è disegnato per supportare uno specifico Battery Pack. Soltanto l’uso di uno specifico battery pack, indicato sotto, supporta uno specifico UPS. Questi battery pack devono essere gestiti con i modelli appropriati di UPS Modello Battery pack 1kVA...
  • Page 7 4 Descrizione pannello posteriore Pannello posteriore 1/2/3kVA Figura 2 pannello posteriore battery pack 1/2/3kVA 1. L'interruttore automatico CC collega e disconnette la tensione del bus CC dal pacco batteria all'UPS. L'interruttore automatico CC si disconnetterà in caso di sovracorrente. 2. Il connettore della batteria esterna è per “Daisy Chaining”, ovvero concatenare batterie aggiuntive e / o collegarsi all'UPS.
  • Page 8 1. L'interruttore di circuito CC sul retro del pacco batteria collega e disconnette la tensione del bus CC dal pacco batteria all'UPS. L'interruttore di circuito CC scatta anche in posizione OFF in caso di sovracorrente nella batteria. Figura 3 vista posteriore pacco batterie 1/2/3kVA 2.
  • Page 9 6 Specifiche di sistema MODELLI BATTERY PACK 1KVA Battery Pack 2KVA Battery Pack 3KVA Battery Pack Tensione 220/230/240 VAC Corrente AC 0.5A 1.5A INGRESSO Frequenza 50/60 Hz Protezione ingress Interruttore resettabile Tensione DC 27.5 ±0.5V 55.0 ±0.5V 82.5 ±0.5V USCITA Corrente DC 2.0A CARICATORE...
  • Page 10: Table Of Contents

    CONTENTS 1. Introduction 2. Safety 3.Front Panel Description And Operations 4.Rear Panel Description 5.Extended Battery Pack Operation 6. System Specifications Ver.00 07 Febbraio 2019...
  • Page 11: Introduction

    1. Introduction The battery pack Series of Products has been designed to provide quality power protection at outstanding prices. The External Battery Packs have been designed with removable battery cartridges and individual chargers for maximum value. 7 2. Safety IMPORTANT SAFETY INSTRUCTIONS: It is imperative to SAVE THESE INSTRUCTIONS! NOTE: Please read this manual before installing the 1KVA-3KVA battery pack, model 1KVA battery pack, 2KVA battery pack, 3KVA battery pack as it provides important safety information.
  • Page 12: Front Panel Description And Operations

    Battery Packs. Please Note: Each UPS has different DC bus voltages and each UPS is designed to mate with a specific Battery Pack. Only use the specific Battery Pack, stated below, with its appropriate UPS. These Battery Packs MUST be operated with their respective UPS models, see the table below: 1KVA battery pack 2KVA battery pack 3KVA battery pack...
  • Page 13: Rear Panel Description

    LED Description The Charging LED GREEN indicates that the battery charger in the External Battery Pack is charging normally with the AC power cord attached to the Battery pack. The Battery Test LED GREEN indicates that the DC output of the External Battery Pack is normal. To perform the Battery Test.
  • Page 14: Extended Battery Pack Operation

    3. Switch on the DC circuit breaker. At this point, the UPS will need to be started. Please refer to the recommended process in the UPS User’s Manual. NOTE: If connecting more than one Battery Pack please refer to the Daisy Chaining section. CHARGING THE BATTERY If the Battery Packs are plugged into an AC source and properly installed, the internal batteries will be charged when acceptable voltage is provided.
  • Page 15: System Specifications

    Figure 5 Daisy chain 3. The input AC Circuit Breaker will trip to the OFF position in the event that the internal Battery Pack charger draws excessive current. 11 6. System Specifications EXTENDED BATTERY PACK 1KVA Battery Pack 2KVA Battery Pack 3KVA Battery Pack MODELS Voltage...