8 ASYMETRICAL VS SYMETRICAL DATA SIGNALS: ....12 9 ARTNET, FEATURES AND HINTS: ..........13 10 ARTNET NODE PHYSICAL LAYOUT........13 11 CONNECTING THE ARTNET NODE TO A PC ......15 11.1 PC....... 15 HYSICAL CONNECTION OF THE ET NODE TO A 11.2...
Following symbols are used to identify important safety information on the product and in this manual. p.7/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Never bypass the fuse or change the fuse with another type or value as is rated in this manual. p.8/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
SPI compatible, but in reality, this is seldom the case. Timing is very important on an SPI-variant bus, so it might be possible that you will not find a setting on the ArtNet node which is compatible with your ledstrip. (or that it is not stable)
On the picture above, you can clearly see DO (data output) and DI (data input) To overcome the problems with longer cable lengths, Lux Lumen made the 6 outputs on the card so, that they output a symmetrical signal. This makes that you can have longer cable lengths as in standard non symmetrical SPI-variants.
Power input IP-address Ethernet ports MAC-address Software version Serial Number Data output ports RJ45 connector p.13/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Page 14
The ArtNet node has 6 six independently programmable data output ports. The Artnet node has an internal switch on the ethernet ports. This switch can handle up to 300 DMX universes in broadcast. So this means, it can handle up to 300 DMX universes on its artnet ‘input’, and send 300 DMX universes to the...
Connecting the ArtNet node to a PC 11.1 Physical connection of the ArtNet node to a PC. If you want to view or change the settings of the ArtNet node you need to connect a windows PC to the ArtNet node.
For example: 5.11.654.231 is an IP address in subnet number 5. You have to set the IP address on your PC to the same subnet as the IP address of the ArtNet node. Since the ArtNet standard always uses IP addresses in the subnet ‘2’, the IP address on the PC has to be 2.xxx.xxx.xxx.
11.4 Change subnet on a PC To set the PC to the same subnet as the ArtNet node you have to set a fixed IP address on your PC. - Click on the windows “start” button in the left bottom corner.
Page 19
- find the adapter corresponding with the connector you used to connect to the ArtNet node. usually it is the “ethernet” adapter. - Right click on the adapter. - Click on “Properties” Select “Internet Protocol version 4 (TCP/IPv4) p.19/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 –...
Page 21
- Fill in the wanted IP address. The first numbers should be ‘2’, the same as the IP address of the ArtNet Node (this is the subnet). The last number must be different to avoid IP conflict. We recommend using the following first two digits: 2.0.xxx.xxx.
11.5 Set your PC back to the old settings: p.23/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
It is not possible to connect another node to the network via the output ports. A data output port on the ArtNet node only sends out the data with the protocol and universe(s) configured for that port. If nothing configured no data will be send out that port.
• In case of YD pixels of the first generation, which uses SPI + Clock signal, both of them can be combined over one cable. p.25/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
On the webpage you can obtain info about the settings of the ArtNet node. You cannot change the settings via the web page. With a browser (eg.chrome) surf directly to the IP address of the ArtNet node. In the example below, the IP address of the node is 2.121.16.69. p.26/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK –...
Once you did run this .exe file, you will see a screen similar to the one below. p.27/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44...
Page 28
All detected nodes will appear on the left side. When you click on the node you can change the settings. p.28/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Page 29
As example, you can see what text appears if you hold your cursor on the field ‘512’. p.29/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Page 30
On the PCB are solder-points to re-direct the clock line to the data line connector. See chapter 8.2 for more info. p.30/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
It is possible to specify 10 completely different universes in any order. Duplicate universes are not allowed. Enter a number between 0 and 32767 p.31/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
We strongly recommend to select this txt, and paste it in a .txt file, and save this in a safe environment. Please name this file with the IP address of the ArtNet node, so you can easily retrieve Example of this .txt file:...
Load settings from file In the ArtNet configurator you can load settings from a text file. When you replace an ArtNet node find the file named with the IP address from the old ArtNet node and open it. Copy the text from the file and paste it in the text field in the ArtNet configurator.
Warranty service is valid for one year from the date of purchase by the consumer, as evidenced by invoice date given out by your point of sale. Warranty service Service under warranty can only be done by Lux Lumen. Coördinaties: Lux Lumen Kernenergiestraat 53 A...
Page 39
IP and IK degree, mentioned in the product specifications in this manual. Repairs, modifications or cleaning carried out by a non Lux Lumen service centre. Use of spare parts, software or consumables, which are not compatible with the product.
RMA procedure To send material back to Lux Lumen, you need a RMA (Return Material Authorization) document that you will receive from Lux Lumen. Without the RMA document, we cannot accept the material. The procedure to obtain a RMA: Step1: Customer contacts Lux Lumen about warranty, defects if material has to be returned.
Page 41
• °C: Temperature in degrees Celsius • din-rail: rail used in electrical installation according to ‘Deutsche Industry Norm’ specifications p.41/41 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK – BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Need help?