Safety Instructions; Scope Of Delivery - Dometic Frigo DC Service Manual

System flushing for electrical transport refrigeration system
Hide thumbs Also See for Frigo DC:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Frigo DC
1

Safety Instructions

The manufacturer accepts no liability for damage in the following cases:
• Faulty assembly or connection
• Damage to the product resulting from mechanical influences and incorrect connec-
tion voltage
• Alterations to the product without express permission from the manufacturer
• Use for purposes other than those described in this manual
1.1
General Safety
DANGER!
• Only with stationary cooling (optional): In stationary operation the transport
refrigeration system operates with a voltage of 230 V which causes a risk of death.
Ensure that you do not come into contact with live parts.
WARNING!
• Assembly and repair of the transport refrigeration system may only be carried out by
qualified personnel who are familiar with the associated risks and the relevant reg-
ulations. Improper repairs can cause considerable danger. If repairs are necessary,
contact the service center in your country.
• Inhalation of gaseous refrigerant can cause suffocation. Ensure that the refrigerant is
properly drained off with an A/C service unit before opening the cooling system.
• If the transport refrigeration system shows visible damage, it must not be put into
operation.
• Risk of injury due to leaking liquids if the transport refrigeration system is damaged.
Liquids leaking on the floor can cause people to slip and injure themselves. Immedi-
ately wipe up any leaking or dripping liquids or absorb them with a suitable binding
agent and dispose of them in an environmentally friendly manner.
1.2
Safety during Installation
WARNING!
• The installation may only be carried out by persons who have a certificate of compe-
tence, for example in accordance with EC Regulation 307/2008, for installation and
start-up of transport refrigeration systems.
• Wear protective clothing (especially eye protection and protective gloves) when
working on the transport refrigeration system.
2

Scope of Delivery

No. in fig. 1
1
2
3
EN
Amount
Description
1
Adapter for filling hose 3/8"
1
Adapter for filling hose
1
Adapter, straight 5/8"
Scope of Delivery
Ref. no.
8885400343
8885400162
8885400541
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Frigo dc2500Frigo dc3500

Table of Contents