Lawler 3000 Installation & Maintenance Manual

Lawler 3000 Installation & Maintenance Manual

Thermostatic shower valve

Advertisement

Quick Links

NOTICE!
No mixing valve will work satisfactorily if improperly installed. We suggest, therefore, that you read
these instructions carefully before installing and follow directions as outlined. Handle the mixing valve with care.
CAUTION: When maintaining and adjusting the
mixing valve, all fixtures should be isolated from
use. Lawler Manufacturing Co., Inc. recommends
that you work safely at all times and in a manner
consistent with the OSHA Lock/Tagout standard,
29 CFR 1910.147 and other applicable standards.
This installation & maintenance manual covers all
configurations of the Model 3000.
3500 less stop & check valves
B
72047_3500-50_STD_DRW_NODIMS.pdf
A
A
C
DIMENSIONS
Valve Number
A N.P.T. B N.P.T.
3500
1/2"
Dimensions are for reference purposes only. For rough-in dimensions
please refer to Lawler's Revit/BIM models found at temperedwater.com.
ASSE 1070 Approved
ASSE Lead Free Certified
Certified to CSA B125.3
INSTALLATION &
MAINTENANCE MANUAL
D
C
D
1/2"
7-1/2"
5-1/8"
Design and specifications subject to change without notice.
Please refer to temperedwater.com to ensure most
current data sheet and other design solutions.
Model 3000
Thermostatic Shower Valve
3800 less stop & check valves
A
Valve Number
3800
Dimensions are for reference purposes only. For rough-in dimensions
please refer to Lawler's Revit/BIM models found at temperedwater.com.
3900 less stop & check valves
A
E
E
Valve Number
3-1/2"
3900
Dimensions are for reference purposes only. For rough-in dimensions
please refer to Lawler's Revit/BIM models found at temperedwater.com.
temperedwater.com
73047_3800-50_STD_DRW_NODIMS.pdf
B
A
C
DIMENSIONS
A N.P.T.
B N.P.T.
1/2"
1/2"
74147_3900-50_STD_DRW_NODIMS.pdf
B
A
C
DIMENSIONS
A N.P.T.
B N.P.T.
1/2"
1/2"
temperedwater.com/patents
5330 East 25 th St.
Indianapolis, IN 46218
Phone (317) 261-1212
Fax (317) 261-1208
D
C
D
3-1/2"
4"
D
C
D
10-1/2"
5-1/2"
M 3000 E

Advertisement

loading

Summary of Contents for Lawler 3000

  • Page 1 Dimensions are for reference purposes only. For rough-in dimensions that you work safely at all times and in a manner please refer to Lawler’s Revit/BIM models found at temperedwater.com. consistent with the OSHA Lock/Tagout standard, 29 CFR 1910.147 and other applicable standards.
  • Page 2 Inspection and Cleaning Valve Maintenance Shut off hot and cold water supply to mixing valve. Set The Lawler thermostatic mixer should be checked mixing valve handle on maximum hot position. Remove periodically for proper operation and cleaning. See body screws #9. Turn mixing valve handle toward cold “INSPECTION AND CLEANING VALVE.”...
  • Page 3 Checking the Thermostat Thermostatic Shower Valve Cut-away If cold seat #13 on thermostat is worn or deeply indented, remove it and replace with a new one. If there is a question as to the thermostat being good, hold thermostat under cold water faucet and insert an eraser capped pencil into the center of thermostat.
  • Page 4 GUARANTEE We guarantee the Lawler Mixing Valve to be free from def ects in workmanship and material, and for a period of one year from date of purchase, will replace any parts found by us to be defective. We will not be held responsible, however, for any labor incidental to, or for any damages caused by defective material.

This manual is also suitable for: