PREPARING FOR INSTALLATION:
Consider the most convenient location to mount the V-12/AWE. Use the PVC
junction box (supplied), mounted atop a PVC conduit through which the wires
will run. Count the number of pairs of 4-ohm speakers and the number of pairs
of 8-ohm speakers you are connecting. Count pairs of 6-ohm speakers as 4-ohm
pairs. Determine the correct switch position from the impedance charts in the
owner's manual.
INSTALLATION:
1. Identify the Keypad wire. Label the wire for future reference.
2. Terminate the CAT5 Keypad wire with a RJ-45 connector.
3. Locate the preprinted label sheet.
4. Detach the labels you will be using.
5. Remove the Decora style insert.
6. Remove the plastic source key caps.
7 . Insert the labels in the keycaps and position them in the appropriate source
key locations.
8. Replace the Decora style insert
9. Connect the terminated Keypad wire to the M-4KP terminal labeled SYSTEM.
10. Install the M-4KP into the device ring.
11. Fasten the cover plate
M-4KP INSTALLATION DIAGRAM
M-64 Multi-Zone
Receiver
FOUR SOURCE MULTIZONE KEYPAD
Category
M-4KP
5 Wire
Speakers
JOBSITE SYSTEMS
12331 SW 130 STREET
MIAMI, FL 33186
P 866.4JB.SITE (866.452.7483)
F 305.238.0185
WWW.JOBSITESYSTEMS.COM
©2004 Niles Audio Corporation. JobSite,
Pure Custom and Niles are registered
trademarks of Niles Audio Corporation
and the JobSite Logo is a trademark of
Niles Audio Corporation. JSM4KPPDF
Specifications subject to change without notice.
M-4KP

Advertisement

loading

Related Products for Jobsite M-4KP