Four-character display
Displays status, provisioning, and
alarm messages. See tables below
for a list of message descriptions.
Normal operation.
Green LED
Flashing Green LED
HDSL2 acquisition.
Red LED
Fuse alarm.
System alarm.
Flashing Red LED
Customer Remote Loopback (CREM)
Yellow LED
or Network Local Loopback (NLOC)
is in effect.
Flashing Yellow LED
System is in Armed (ARM) mode.
Off
Line power is off.
L
T
OOPBACK
ESTING
Initiate loopback testing from the HiGain Solitaire Monitor screen or use the MODE and SEL
buttons. The inband codes below can also be sent by a test set.
A3LB Loopback Commands
Loopback
Inband Code
NLOC
1111-1111-0001-1110 (FF1E)
(a)
NRG1
1111-1111-0000-0100 (FF04)
(a)
NRG2
1111-1111-0000-0110 (FF06)
NREM
1111-1111-0000-0010 (FF02)
SMJK
1111-1111-0100-1000 (FF48)
100000
11000
CREM
0011-1111-0001-1110 (3F1E)
CRG1
(a)
0011-1111-0000-0100 (3F04)
(a)
CRG2
0011-1111-0000-0110 (3F06)
CLOC
0011-1111-0000-0010 (3F02)
Loopdown
1111-1111-0010-0100 (FF24)
11100
100
(a) Regenerators (doublers) are supported in firmware version 3.0 and higher.
For more information about the HiGain Solitaire HDSL2 maintenance screens, refer
to the H2TU-C-388 List 1E technical practice, section number 152-388-115-xx. This
practice can be downloaded from the Customer Site portion of the ADC Web page at
www.pairgain.com. A password is required for access to the Customer Site Web pages.
If you do not have a password, contact your ADC sales representative.
Front-Panel Alarm Messages
Message
Description
LOSW
The HDSL2 loop has lost sync.
LLOS
No signal is detected at the DSX-1 input to the H2TU-C.
RLOS
No signal is detected at the DS1 input to the H2TU-R.
MAL
The margin on HDSL2 loop has dropped below the threshold setting.
LAIS
Local Alarm Indication Signal.
(a)
RAIS
Remote Alarm Indication Signal.
(a)
RRAI
An RAI alarm from the Customer Premises Equipment (CPE) with a failure from the network.
(a)
TRCI
An RAI alarm from the CPE with no failure from the network. Sends RAI-CI to the
network.
LA
The attenuation on the HDSL2 loop has exceeded the maximum threshold value.
(a)
DBER
A system DS1 Bit Error Rate (BER) alarm.
HBER
A system HDSL2 Block Error Rate (BER) alarm.
SHRT
A short between the Tip and Ring of the HDSL2 pair.
GND
The HDSL2 loop is grounded.
OPEN
A line power open condition.
(a)
PRMF
H2TU-R Performance Report Messaging BER threshold exceeded at far end.
(a)
PRMN
H2TU-R Performance Report Messaging BER threshold exceeded at near end.
(a) Alarm messages are listed in order of priority. ALRM displays prior to any alarm message. Pressing the
SEL button initiates an Alarm Cutoff (ACO) message.
Front Panel
List number
HiGain
SOLITAIRE
HDSL2
L
H
2
T
CLEI code label
U
C
3
8
8
SETUP
MODE SEL
Status LED
STATUS
RS
232
DCE
PAIRGAIN
Configuration number
RS-232 Craft port
The Bantam 210 jack provides bidirectional communication
between the H2TU-C and a maintenance terminal
for access to maintenance, provisioning, and
performance screens. Use jack adapter 120-1035-01
to connect a standard 9-pin terminal cable between the
serial port on a PC and the H2TU-C craft port.
Description
DSX-1 signal is looped back to the network at the
H2TU-C.
DSX-1 signal is looped back to the network at H2RU1.
DSX-1 signal is looped back to the network at H2RU2.
DSX-1 signal is looped back to the network at the
H2TU-R.
DSX-1 signal is looped back to the network at the
H2TU-R SmartJack module. (Choose any one of the
three commands.)
Signal from customer is looped back to the customer at
the H2TU-C.
Signal from customer is looped back to the customer at
H2RU1.
Signal from customer is looped back to the customer at
H2RU2.
Signal from customer is looped back to the customer at
the H2TU-R.
Deactivates any of the above loopbacks. (Choose any
one of the three commands.)
(a)
Maintenance Terminal Modem Settings
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control: OFF
Terminal emulation software: VT100
System option buttons (for manual setting of
system parameters)
Use MODE and SEL to manually modify user options,
initiate loopbacks, and display DSX-1 line parameters.
1
Press the MODE button for 1 second and release.
The front panel alternately displays the first
system parameter and its current setting.
2
Press SEL to step through all possible system
settings for the displayed parameter.
3
Press MODE to update the parameter and advance
to the next parameter.
4
After scrolling through all the parameters, press SEL
to confirm changes when prompted with a CONF NO
message, or press MODE to cancel all changes.
Display Code
Description (normal operating messages in bold)
A=xx
The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ
The multiplexers of the H2TU-C-388 and H2TU-R are trying to establish synchronization.
AnL
The multiplexers of the two devices on Span n are trying to establish synchronization
with each other, where n is the number of the span.
ARM
Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT?
The H2TU-C is not receiving a response from the H2TU-R.
FERR
A framing bit error occurred at H2TU-C DSX-1 input.
FLDL
Flash download of firmware updates. (Contact Customer Service for update procedures.)
HES
H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV
A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx
Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to
21.5 dB). Any value of 6 dB or greater is adequate for reliable system operation.
MNGD
The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED ON
Indicates that the HDSL2 loop is not grounded or shorted.
PWR FEED OFF
HDSL2 span power is turned off.
SIG
The tranceivers of the H2TU-C and H2TU-R (or the H2TU-C and first regenerator) are
trying to establish contact with each other on Span 1 of the HDSL2 loop.
SnL
The tranceivers of the two devices on Span n are trying to establish contact with each
other, where n is the number of the span.
Front-Panel Configuration Options Using MODE and SEL
Display Code
Description (default values in bold)
EQL
Sets the DSX-1 Equalizer to: 0 (0 to 133 ft.), 133 (133 to 266 ft.), 266 (266 to 399 ft.),
399 (399 to 533 ft.), 533 (533 to 655 ft.).
RLBO
Sets the H2TU-R line buildout to 0 dB, -7.5 dB, or -15 dB.
LPBK
Enables (ENA) or disables (DIS) SmartJack loopback commands.
FT1
Enables (ENA) or disables (DIS) system response to DDS latching loopback commands
for fractional T1 applications.
SPLB xxxx
Configures the system for generic (GNLB) or special inband loopback commands (A2LB,
A3LB, A4LB).
PWRF
OFF = disables HDSL2 powering. ON = HDSL2 line voltage is -185 Vdc maximum.
HBER
1E-6 or 1E-7 = alarm activates when the HDSL2 BER alarm threshold exceeds 10
NONE = prevents generation of a system alarm due to BER.
DBER
Enables (ENA) or disables (DIS) fixed 24-hour DSX-1 BER alarm threshold.
LBTO
Loopback timeout = NONE, 20, 60, 120 minutes.
DS1
DSX-1 line code = B8ZS or AMI.
CONV
H2TU-R frame format conversion = OFF (framing determined by the DS1 frame formatting
option), ACON (autodetection of framing and potential frame conversion at the H2TU-R),
or FCON (autodetection of framing and forced frame format conversion at the H2TU-R).
FRMG
DS1 frame formatting = AUTO (auto framing mode) or UNFR (unframed mode).
ALMP
Enables system to output an alarm pattern: AIS or LOS.
BPVT
Enables (ENA) or disables (DIS) Bipolar Violation Transparency.
NLBP
Enables the H2TU-R to transmit either AIS or LOS towards the CI for any network loopback.
TLOS
Enables (ENA) or disables (DIS) a logic loopback at the H2TU-R when an LOS occurs at its
DS1 input.
RTPV
Enables (ENA) or disables (DIS) remote provisioning.
PRM
OFF = no enhanced Performance Report Messaging; SPRM = Supplemental PRM;
NPRM = Network PRM; S + N = SPRM + NPRM.
NAIS
If ALMP is set to AIS, this option specifies which pattern is sent to the network when a
remote LOS or AIS occurs. CI = AIS-CI sent to the network; AIS = AIS sent to the network.
ROVR
Enables (ENA) or disables (DIS) conversion of an ESF T1 payload (from the network) with
an embedded RAI pattern to an SF-RAI pattern towards the CI at the H2TU-R. CONV
option must be set to FCON or ACON.
RACI
Enables (ENA) or disables (DIS) conversion of a DS1 SF-RAI signal received by the H2TU-R
to an SF-RAI-CI signal towards the network.
Front-Panel System Information Messages (Scroll Mode)
Code
Description
CODE xxxx
The line code setting (AMI or B8ZS).
FRM xxxx
Indicates the type of frame pattern being received from the DSX-1 (SF, ESF, UNFR).
LATT xx
Loop attenuation threshold (0 to 35 dB). Default is 0.
LIST xx
The list number of the product.
MARG xx
Margin threshold (0 to 15 dB). Default is 4.
VER x.xx
The firmware version.
(a) To scroll through system information messages, press the MODE button for 3 or more seconds.
Card-edge Connector
219
119
Ground
218
118
-48Vdc
217
117
216
116
215
115
214
114
213
113
212
112
211
111
210
110
209
109
208
108
107
207
206
106
205
105
204
104
203
103
202
102
201
101
200
100
* Fuse alarm is normally floating (0 to 80 V maximum)
and at -48 Vdc (10 mA maximum) when activated.
Front-Panel Diagnostic Messages
Frame ground
Ground
Fuse alarm*
Ring 1
DSX-1 OUT
Tip 1
Ring
DSX-1 IN
Tip
Factory use only
Ring
Tip
HDSL2 span