  • Page 1 Operator Manual for Element C-Band 10W BUC...
  • Page 2: Table Of Contents

    Element BUC Installation ..................10 Check packing list ....................10 Installation of mounting bracket ................10 Connecting coaxial cable and DC ..............11 Installation of OMT to CPR137G ..............11 Waterproof .......................11 Maintenance ......................13 Troubleshooting .......................13 ©Norsat International Inc. (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 3 Figure 2-5: MS 2pin for DC ............................9 Figure 3-1: Location of mounting bracket holes ......................10 Figure A-4- 1: Element 10W BUC (DC Power)......................14 Figure A-4- 2: Element 10W BUC (AC Power) ......................15 ©Norsat International Inc. (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 4 LIST OF TABLES Table 2-1: Torque Value ..............................8 Table 3-1: Torque Value .............................. 11 Table 3-4: Torque Value .............................. 11 Table B-4- 1: Acronyms and Abbreviations ........................16 ©Norsat International Inc. (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 5: Overview

    Introduction of BUC The BUC is designed to use for VSAT application. Norsat BUC has high linearity and gain stability over the full operating temperature range. The standard output operating frequency range is 5.850GHz to 6.425GHz.
  • Page 6: Safety

    The BUC should be handled with care to avoid potential safety risks. Read the following instructions prior to using the BUC. Norsat is not responsible for damages occurred by unsafe handling of the product. 1. Do not disassemble the BUC. It may cause malfunction and electrical shock.
  • Page 7: Intermediate Frequency (If)/ 10Mhz Reference Input

    Intermediate Frequency (IF) and 10MHz reference signal are provided through F or N type connector. F or N type connector is used for the input port as shown in Figure 2-1 and Figure 2-2. Figure 2-1: F-Type female connector Figure 2-2: N-Type female connector ©Norsat International Inc. (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 8: Torque Value

    2.4 AC/DC Connector MS 5pin connector is used for AC and MS 2pin connector is used for DC as shown in Figure 2-4 and Figure 2-5. CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 9: Figure 2-4: Ms 5Pin For Ac

    Figure 2-4: MS 5pin for AC Figure 2-5: MS 2pin for DC CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 10: Element Buc Installation

    Please do not block the fins so that heat sinks are open to fresh air. Adequate cooling for the BUC is important in providing years of top performance. Figure 3-1: Location of mounting bracket holes CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 11: Connecting Coaxial Cable And Dc

    Use the self-amalgamating tape provided to seal the junction between the connector and coaxial cable. Detail instruction to use the self-amalgamating tape is as following: 1. Connect the coaxial cable to BUC connector. CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 12 2. Tighten connector and coaxial cable all the way to the end. 3. Tightly wrap the connector and coaxial cable with the self-amalgamating tape. 4. Tightly wrap the waveguide filter or OMT with the self-amalgamating tape. CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 13: Maintenance

    The recommended action below provides some help to quickly isolate a fault within the BUC module. If the BUC module is defective, notify Norsat of a written description of the problem encountered, the part number and serial number of the unit in question.
  • Page 14: Figure A-4- 1: Element 10W Buc (Dc Power)

    Appendix A Mechanical Drawings Figure A-4- 1: Element 10W BUC (DC Power) CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 15: Figure A-4- 2: Element 10W Buc (Ac Power)

    Figure A-4- 2: Element 10W BUC (AC Power) CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...
  • Page 16: Table B-4- 1: Acronyms And Abbreviations

    Table B-4- 1: Acronyms and Abbreviations Acronym Definition Block Upconverter Intermediate Frequency Direct Current Gigahertz Ground M&C Monitor and Control Megahertz Millimeter Radio Frequency Receive Transmit Volt Volts Direct Current CONFIDENTIAL AND PROPRIETARY ©Norsat International Incorporated (“Norsat”) All Rights Reserved 2022-06-01 DOC-001803 Rev A...