ZEBRA-24.60 The present user manual applies to volumetric microwave security sensor ZEBRA-24.60 (hereinafter “Sensors” for all modifications) available in three modifications: ZEBRA-24.60, ZEBRA-24.60.A with an extended temperature range and ZEBRA-24.60.BT configurable via wireless Bluetooth interface. The user manual contains information necessary for studying sensors and the principle of their operation, installation, powering and commissioning.
Birds and small animals with the linear dimensions up to 0.3 m moving in the detection zone at a distance less than 5 m from the sensor Operation of the second sensor with a different frequency letter on the same area with partial overlap of the detection zone ZEBRA-24.60 User Manual October 17, 2019...
Operating conditions The sensors are resistant to environmental conditions and mechanical stress. The temperature range for ZEBRA-24.60 and ZEBRA-24.60.BT: -40° to +80°С The temperature range for ZEBRA-24.60.A: -60°to +80°С. The sensors are configurable via Bluetooth interface at - 25° to + 75°C.
Page 6
50-55 m 55-60 m Note: the distances given in table 1.1 are approximately and can be slightly different depending on the factory adjustment errors, sensitivity settings, surface effect and reflecting objects in the detection zone. ZEBRA-24.60 User Manual October 17, 2019...
Page 7
ZEBRA-24.60 ZEBRA-24.60. ZEBRA-24.60. 1.2.2 Detection zone parameters of ZEBRA-24.60 meet ones given in item 1.2.1 under conditions of items 1.2.2.1, 1.2.2.2. 1.2.2.1 The protected area (site) should meet the following requirements: Maximum height of irregularities shouldn`t exceed + 0.3 m Height of the grass cover shouldn`t exceed 0.2 m...
Page 8
The sensor goes back to the standby mode within 5 seconds after alarm. 1.2.8 The sensors ZEBRA-24.60 and ZEBRA-24.60.BT are powered from 10 up to 30 V DC with the maximum pulsation of 0.03 V. The maximum power consumption is 1.5 ZEBRA-24.60 User Manual...
Page 9
ZEBRA-24.60 The sensor ZEBRA-24.60.A is powered from 20 up to 28 V DC. The current consumption is 270 mA at a voltage of 24 V. 1.2.9 The sensor ZEBRA-24.60.A has a built-in automatic heat stabilizer, which is activated when the ambient temperature drops below minus 25 ± 5 ºС and ensures operation of the sensor at minus 60 ºС.
ZEBRA-24.60 Сomponents 1.3.1 The sensors have three modifications (please see table 1.2). Table 1.2 – Modifications of ZEBRA-24.60 Modifications ZEBRA-24.60 ZEBRA-24.60.A ZEBRA-24.60.BT 1.3.2 Table 1.3 shows the completeness of sets. Table 1.3 – Delivery set of ZEBRA-60(24) Name Q-ty Note ZEBRA-24.60...
Page 12
Table 1.5 – Kit of tools and accessories Name Q-ty Note 1 Kit of tools and accessories: S10х10 1.1 Wrench/open end spanner 1.2 Cable USB-B M- USB-A M (1.8 м) Note – When ordering, please note frequency letters. ZEBRA-24.60 User Manual October 17, 2019...
– The appearance of the cable gland and conduit adapter for the Note corrugated tube may differ from ones shown on the picture. Figure 1.2 – Construction of ZEBRA-24.60 ZEBRA-24.60 User Manual October 17, 2019...
Page 14
Figure 1.3 shows the configuration elements located under the lid. 1 – ALARM LED 2 – TAMPER LED 3 – USB PORT Figure 1.3 – Configuration elements of ZEBRA-24.60 1.4.3.2 Mode indication: In the mode ALARM the LED is ON within 3 seconds In the mode OPERATION the LED is OFF.
Page 15
After the automatic control has been done, the sensor switches to the standby mode. When triggered, the sensor generates an alarm within 3 seconds and then switches to the normal state within 5 seconds. ZEBRA-24.60 User Manual October 17, 2019...
Tablet on basis of Android with the Bluetooth-interface (for modification ZEBRA-24.60.BT) Remote computer connected to the sensors via interface RS-485. Marking 1.6.1 The sensor marking contains: Trademark name Sensor name Serial number Year and quarter of manufacture. ZEBRA-24.60 User Manual October 17, 2019...
Page 17
Address, telephone number (fax), e-mail and website of the supplier Power supply voltage range Application area Application properties (functional specifications) Picture of the appearance of the sensor Date of packaging Manipulation signs and signs of transportation conditions. ZEBRA-24.60 User Manual October 17, 2019...
If such factors take place, due to reflections and interferences the detection zone is distorted. 2.1.6 On objects with the increased lightning statics, it is necessary to use lightning units. The lightning units should be used when the length of connecting lines exceeds 300 ZEBRA-24.60 User Manual October 17, 2019...
Check the completeness of the sensor. 2.2.2.4 Check the presence of the quality department stamp in the passport of the sensor. 2.2.2.5 The sensors should be free from defects like deep scratches and dents. ZEBRA-24.60 User Manual October 17, 2019...
Install the posts. As posts it is recommended to use metal pipes with a diameter of 70…90 mm. The height of the post above the ground should be at least 1100 mm. In areas with much snow, the above-ground part of the post should be at least 1500 mm. ZEBRA-24.60 User Manual October 17, 2019...
Page 21
2.3.2.5 The above-ground part of the post should be at least 1100 mm. Figure 2.1 shows the post installation. ZEBRA-24.60 User Manual October 17, 2019...
Page 22
5 - holes to enter the main cable; 6 - concrete (gravel); 7- rebars to prevent an unauthorized demounting; 8 - ground. Note 1 At size A, lay the ground after the installation. 2 Dimensions are given in mm. Figure 2.1 – Post installation ZEBRA-24.60 User Manual October 17, 2019...
Page 23
If the posts can`t be installed and there is a rigid fence, so it is recommended to mount ZEBRA-24.60 on brackets 1000 or 1250 mm long. Such brackets can be used for mounting sensors and junction boxes on the fence or to the wall.
Page 24
ZEBRA-24.60 2.3.4.2 Mount the sensors on brackets following item 2.3.3. ZEBRA-24.60 User Manual October 17, 2019...
Page 25
- 2 pcs Note: Mounting on the post using a protective visor (from the mounting kit). Visor pos. 7 is to mount by outdoor installation. Dimensions are in mm. Figure 2.2 – Mounting on the post ZEBRA-24.60 User Manual October 17, 2019...
Page 26
Installation order of ZEBRA-24.60 on the protected surface. 2.3.5.1 Depending on the application task, the sensors ZEBRA-24.60 can be mounted on brackets with overhang of 500, 350 and 120 mm: 500 mm bracket is recommended, if the top of the fence is protected with physical protection means (reinforced twisted barbed tape, razor wire etc.) (see...
Page 27
- 2 pcs.; - 1 pc. 6 - screw М6х50 - 4 pcs.; Figure 2.3 – Mounting on bracket 500 mm (350 mm) Note: Mounting on the surface without protective visor. Dimensions are in mm. ZEBRA-24.60 User Manual October 17, 2019...
Page 28
Figure 2.5 shows mounting of the sensor using brackets 500, 350 120 mm 2.3.5.9 Rotation angle of the transceiver on the bracket: In the horizontal plane - 180 In the vertical plane: up – through angle 17 , down – through angle 45 ZEBRA-24.60 User Manual October 17, 2019...
Page 29
350 mm should be used because of absorption and reflections from the wall the technical characteristics can be deteriorated. The size and material of the fence is not standardized. The fence should be rigid. ZEBRA-24.60 User Manual October 17, 2019...
Page 30
White Supply plus (+) Brown Supply minus (-) Yellow Relay contacts (NC) Pink Purple Tamper circuit (TAMPER) Black Green Remote control (RC) RS-485 «В» Blue RS-485 «A» For sensor Grey Bluetooth activation ZEBRA-24.60.BT only ZEBRA-24.60 User Manual October 17, 2019...
Page 31
2.3.6.3 To activate the Bluetooth interface on ZEBRA-24.60.BT, connect the grey wire of the transceiver unit to “+” supply. 2.3.6.4 Figure 2.6 shows the connection diagram using the lightning guard unit (LGU)
Page 32
2.3.7.1.1.1 Start the file Config Zebra Sensors_install_v2.04 on the computer. 2.3.7.1.1.2 After the file has been started, it will appear the following window. Figure 2.7 To install the program follow the instructions of the installer shown in Figures 2.8-2.11. ZEBRA-24.60 User Manual October 17, 2019...
Page 33
ZEBRA-24.60 Figure 2.8 Figure 2.9 ZEBRA-24.60 User Manual October 17, 2019...
Page 34
ZEBRA-24.60 Figure 2.10 Figure 2.11 ZEBRA-24.60 User Manual October 17, 2019...
Page 35
USB-slot on the transceiver unit. 2.3.7.1.2.3 Apply power to the sensor. The computer will identify the type of the USB device and will ask you to install the driver following actions in accordance with Figures 2.11-2.15. Figure 2.12 ZEBRA-24.60 User Manual October 17, 2019...
Page 36
ZEBRA-24.60 Figure 2.13 Choose the folder COM-PORT in window of Search and Installation Options. Figure 2.14 ZEBRA-24.60 User Manual October 17, 2019...
Page 37
Click Finish and the sensor is ready for use. 2.3.7.1.2.4 After the virtual COM-PORT driver has been installed, it is necessary to know its number. Please follow: DEVICES MANAGER→PORTS (COM and LPT) →USB SERIAL PORT and remember the number. ZEBRA-24.60 User Manual October 17, 2019...
Page 38
Figure 2.16 If the “Manual search” is chosen, the window shown in Figure 2.17 will be displayed, where you should specify the COM port number, network address by yourself and click the “Search” button. ZEBRA-24.60 User Manual October 17, 2019...
Page 39
If the search is successful, an inscription in green will appear showing a sensor (sensors) is found. Upon detection of several sensors, choose an appropriate one and click Standby Mode. Figure 2.17 If the “Automatic search” is chosen, the search starts immediately (Figure 2.18). ZEBRA-24.60 User Manual October 17, 2019...
Page 40
ZEBRA-24.60 Figure 2.18 ZEBRA-24.60 User Manual October 17, 2019...
Page 41
If the search failed, check the power supply and connection to the computer. If the sensor is found, the data exchange between sensor and computer begins automatically (Figure 2.19). Figure 2.19 Choose the sensor and click Standby Mode. ZEBRA-24.60 User Manual October 17, 2019...
Page 42
The “Choose the sensor” button is used to choose a sensor, if some sensors are connected. By clicking the “Options” button the window will be displayed like shown in Figure 2.21. In this window you can choose baud rate, switch on/off alarm ZEBRA-24.60 User Manual October 17, 2019...
Page 43
(by switching on/off the search method of sensors, the previous one will be active). By clicking the “Configuration” button the sensors enters the appropriate mode (item 2.3.7.2.4). Figure 2.21 ZEBRA-24.60 User Manual October 17, 2019...
Page 44
ZEBRA-24.60 The program window in the mode “Configuration” looks like shown in Figure 2.3.7.2.4 2.22. Figure 2.22 2.3.7.2.5 The factory settings of sensitivity are 50% of the column height. ZEBRA-24.60 User Manual October 17, 2019...
Page 45
The program automatically stars accessing the sensor, no restart required. The “Search” button is used to find occupied/free logical numbers, if the manual search was chosen (Figure 2.16). If the automatic search was chosen, the occupied/free logical numbers are determined automatically. ZEBRA-24.60 User Manual October 17, 2019...
Page 46
To reduce nuisance alarms activate only the subzones that should be activated in accordance to the security task. If the corresponding subzone is deactivated, there is no alarm when crossing the detection zone in this place. ZEBRA-24.60 User Manual October 17, 2019...
3.1.2 Technical service is not required during storage and transportation. 3.1.3 Perform all the works given in the appropriate schedule during the technical service. Correct the failures and revealed. ZEBRA-24.60 User Manual October 17, 2019...
In order to check remotely the sensors operability, apply the voltage of 5 … 30 3.3.2.1 V to the circuit “Remote Control” of the transceiver unit from the control panel respectively to the sensor power supply “–”. The sensor should trigger. ZEBRA-24.60 User Manual October 17, 2019...
Page 49
Remove the snow or change the height of installation of the transceiver on the pole. After changing the height of installation of the transceiver, configure the triggering threshold according to the procedures given in the present User Manual. ZEBRA-24.60 User Manual October 17, 2019...
Inspect protected area area doesn’t meet according to the requirements of necessary items 1.2.2.1, 1.2.2.2 and remove requirements. the defects. 4. The transceiver Replace the transceiver unit. unit is out of order. ZEBRA-24.60 User Manual October 17, 2019...
Mean shelf life time in the factory package at the temperature from plus 5º C to plus 40º C and the humidity 95 % at the temperature of 35º C is not less than 3 years. ZEBRA-24.60 User Manual October 17, 2019...
Strictly follow the manipulation marks on the package during transportation. Utilization The sensors are to be utilized after expiry date. The sensors are to be utilized by the operating company according to actual standard and rules of the country. ZEBRA-24.60 User Manual October 17, 2019...
Need help?