5LG2

IMPORTANT SAFEGUARDS

1.
Do not join battery connector or turn "ON" the battery switch until
installation is complete and AC power is supplied to the emergency
driver.
2.
This product is intended for use with an emergency LED lighting load and
supplies nominal of power and a maximum voltage in emergency mode
for a minimum of 90 minutes.
3.
An unswitched AC power source is required (115-277 VAC, 50/60 Hz) to
power these units
4.
This product 's chassis must be grounded.
5.
This product is suitable for use in damp locations where the ambient
temperature is 0°C minimum, to 60°C maximum. This product is also
suitable for installation in sealed and gasleted fixture. This product is
not suitable for heated air outlets and wet or hazardous locations. For
the 10W models,m aximum allowable case temp is 66°C For the 20W
models, maximum allowable case temp is 70 °C. See the section of
this document for TC measurement location.
6.
This product contains a rechargeable LiFePO4 battery. The battery
must be recycled or disposed of properly.
7.
Make certain all connectors are in accordance with the National
Electrical Codes or Canadian Electrical Cose and any local regulations.
8.
This emergency LED driver is suitable for both factory or field
installation. For field installation, please see the instructions section.
9.
Do not install near gas or electric heaters.
10.
The use of accessory equipment is not recommended by the
manufacturer may cause an unsafe condition.
11.
Do not use this product for anything other than it's intended use.
12.
Equipment should be mounted in locations and at heights where it will
not be subjected to tampering by unauthorized personnel.
13.
For Canadian applications, the output terminal should be in compliance
with the accessibility requirement of the Canadian Electric Code.
14.
This device complies with part 15 of the FCC Rules. Operations is suitable
to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference that may
cause undesired operation.
323-888-1973
15.
To reduce the risk of electric shock, disconnect both normal and
CLASS 2
emergency power supplies and place the battery switch in the "OFF"
OUTPUT
or disconnect the battery connector of the emergency driver before
servicing.
16.
Do not a ttempt to service the battery. It is a sealed no maintenance
battery is used that is not field replaceable. Contact the manufacturer
for information on service.
17.
Servicing should be performed by qualified service personnel only.
Note:
Make sure the necessary branch circuit wiring is available.
An uns witched source of power is required. The emergency
driver must be fed from the same branch circuit as the AC driver.
This product is suitable for field installation with suitable LED loads.
There are Three (3) checks to determine if your luminaire is eligible
for field installation.
1.
Ensure the LED load's rated power is greater than or equal to the
power output of this emergency LED driver. This is to ensure that this
emergency product will not produce more power than the LED load
can handle. Thus ensuring that the LED load will not be damaged
when the sy tem is in the emergency mode.
2.
Verify that the forward voltage of the luminaire s LED array is within the
limits of this emergency LED driver. The forward voltage of the LED array
is commonly designated as Vf and should be found on the luminaire, in
the luminaire specifications, or imprinted directly on the LED arrays. If
multiple LED arrays are to be driven, verify that the total forward voltage
is within the limits of this product. Using a voltage meter, it may be
possible to directly measure the voltage across the LED arrays when
operating from the AC driver.
3.
Ensure the output current of th e LED driver does not exceed 5 Amps.
This is the current into the red/ blue output wire.
techsupport@iuseelite.com
Caution:
DO NOT JOIN BATTERY CONNECTOR OR ACTIVE
BATTERY SWITCH UNTIL INSTALLATION IS COMPLETE
AND AC POWER IS SUPPLIED TO THE EMERGENCY DRIVER
.
O.R.-Revision C: 2/24/21
PAGE 1 OF 4
www.iuseelite.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMG-LED-G2-10W and is the answer not in the manual?

Questions and answers

Summary of Contents for Elite EMG-LED-G2-10W

  • Page 1 EMERGENCY BACKUP INSTRUCTIONS EMG-LED-G2-10W/EMG-LED-G2-10W-FLEX EMG-LED-G2-10W-LP/EMG-LED-G2-10W-FLEX-CP EMG-LED-G2-10W-INTG-FLEX/EMG-LED-G2-20W-INTG-FLEX EMG-LED-G2-20W-EMG-LED-G2-20W-FLEX To reduce the risk of electric shock, disconnect both normal and CLASS 2 emergency power supplies and place the battery switch in the "OFF" OUTPUT or disconnect the battery connector of the emergency driver before SAFETY US-CA EMER.
  • Page 2 Select the appropriate wiring diagram to connect the emergency Emergency Part# Application Notes driver to the AC driver and LED load. Make sure all connections are in EMG-LED-G2-10W Integrated Moun�ng accordance with the National Electrical Code and any local EMG-LED-G2-10W-FLEX Remote Mounting Remote mount test switch regulations.
  • Page 3 MAINTENANCE Although no routine maintenance is required to keep the emergency driver functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: Visually inspect the charging indicator light monthly. It should be illuminated. If the charging indicator is off. Contact tech support. Test the emergency operation of the fixture at 30 day intervals for a minimum of 30 seconds.
  • Page 4 HIPOT TEST Scenario 2: Hipot Test with Emergency LED Driver without AC Driver Caution: PLEASE FOLLOW THE WIRING DIAGRAM BEFORE LED Indicator DOING HIPOT TEST, OTHERWISE IT MIGHT CAUSE Battery & Test Switch Connector DAMAGE TO THE EMERGENCY DRIVER OR AC DRIVER. LED Emergency Line Yellow/Black...

This manual is also suitable for:

Emg-led-g2-10w-flexEmg-led-g2-10w-lpEmg-led-g2-10w-flex-cpEmg-led-g2-10w-intg-flexEmg-led-g2-20w-intg-flexEmg-led-g2-20w-emg-led-g2-20w-flex

Table of Contents