Download Print this page

Advertisement

Quick Links

Rain Detector DRD-12V
Description
Description
Technical Data
Measurement method
Input current (12 V Model )
CE-Conformance
EMV-noise emission
EMV-noise withstanding
Cable gland
Operating voltage chooseable 12 V AC/DC ± 10
Output
Housing
Dimensions (w x h x d)
*依設定需要暖機90~250秒
Article
Rain Detector 12V
Rain Detector 24V
Combined Wall/mast mounting
bracket(Options)
Accessoires(Options)
wall / mast mounting bracket
including mouting hardware
Electrolytic AC measurements
60 mA, Heater 80 - 300 mA (PTC)
50 mA, Heater 40 - 180 mA (PTC)
2014/30/EU
EN 61000-6-3:2011
EN 61000-6-1:2007
M16 x 1,5
%
24 V AC/DC ± 10%
output (relay) 30 V / 4 A,
NO / NC selectable
ABS, ingress protection IP54
80 x 82 x 58 mm
Art.-No.
DRD-12V
DRD-24V
DRD-WAHA
Features
• Safe operation, electrolytic measurement principle
• Deposition can be detected as rain or snow
• Operating voltage 12 or 24V DC/AC
• Large, heated sensor area for fast drying and operation in winter
season
• Potential free contact output (Relay) 30 V/4 A
• Sensitivity and switching mode adjustable
• Universal wall/mast mounting bracket as accessories
Applications
• Nurseries, Agriculture
• Control of Ventilation panels
• Automatic switch for Blinds and Rolling windows
• Building instrumentation
• Weather stations
Functional description
The large sensor area reacts to rain or snow. The switch polarity and
sensitivity are adjustable. The optionally switched heater prevents
freezing or dew formation and accelerates drying. In the maximum
sensitivity setting, the device is also suitable for recognizing fog.
Application
up to 30 V DC/AC which can be used to operate any switching device
e.g. a marking control device. Sensitivity can be adjusted within a wide
range. The device is provided with a heater for faster drying and snow
recognition.
Mounting
Installation of the rain sensor unit should be carried out by only
authorised personnel. The applicable safety regulations should be
followed ! The Rain Sensor can be installed on a wall/mast mounting
bracket. If such accessories are not used, care should be taken that
the mounting angle is approximately 30 ° from horizontal. The points
of sensor area must be on the down side. Mounting of the Rain Sensor
should be done at a place which is freely accessible for rain. Dripping
water can adversely delay switching back or can lead to a permanent
ON/OFF of the contacts.