OneFex CE-IO1600 Manual

Ethernet i/o module
Hide thumbs Also See for CE-IO1600:

Advertisement

Quick Links

CE-IO1600 User Manual
CE-IO1600
Ethernet I/O Module
Manual
1
/ 13

Advertisement

Table of Contents
loading

Summary of Contents for OneFex CE-IO1600

  • Page 1 CE-IO1600 User Manual CE-IO1600 Ethernet I/O Module Manual / 13...
  • Page 2: Table Of Contents

    CE-IO1600 User Manual PRODUCT INTRODUCTION ....................5 Features ............................5 Parameter ............................5 Item Selection ..........................6 Dimension ............................6 WIRING INSTRUCTIONS ..................... 6 Terminal Definition ......................... 6 RS485 Communication Wiring ..................... 6 DO Wiring ............................7 ETHERNET CONFIGURATION&COMUNICATION TEST ........7 Ethernet Parameter Config ......................
  • Page 3 CE-IO1600 User Manual Device Usage Environment ......................34 AFTER-SALE SERVICE ..................... 34 Commitment ..........................34 Disclaimer ............................35 UPDATE HISTORY ....................... 35 / 13...
  • Page 4 CE-IO1600 User Manual Notice ❖ Please read this manual carefully before use and save it for reference. ❖ Please follow to the operating procedures and precautions in this manual. ❖ Please open the package carefully and check whether the device and accessories have been damaged due to transportation when you receive the device.
  • Page 5: Product Introduction

    CE-IO1600 User Manual Product Introduction CE-IO series products are Ethernet I/O module using standard Modbus RTU/TCP protocol, integrates DO (digital output), DI (digital input), AI (analog input). The communication method supports Ethernet networking, 7~40V wide voltage power supply, and supports functions such as logic control between analog acquisition and relay output.
  • Page 6: Item Selection

    CE-IO1600 User Manual Installation 35mm Din Rail Mounting / Screw Holes Item Selection CE-IO0222 2*DI&2*DO&2*AI, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT 2*DI&2*DO&2*AI, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT, CE-IO0222S Timing Control, DI/AI&DO Linkage 2*DI&2*DO&2*AI, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT, CE-IO0222SC Timing Control, DI/AI&DO Linkage, Cloud 4*DI&4*DO&4*AI&4*AO, RS232+Ethernet, Modbus RTU/...
  • Page 7: Do Wiring

    CE-IO1600 User Manual DO Wiring Ethernet Configuration&Comunication Test Ethernet Parameter Config Network Device IP Address Port# Mode Address Ethernet 192.168.1.232 10000 Server There are 2 modes for ethernet parameter configuration Hardware Instuctions Connection The io is directly connected to computer...
  • Page 8 CE-IO1600 User Manual ➢ Open JYNetConfigEn, it shows as below: / 13...
  • Page 9 CE-IO1600 User Manual ➢ Chosse Local connection: ➢ Searching: / 13...
  • Page 10 CE-IO1600 User Manual ➢ Revise parameter ➢ researching / 13...
  • Page 11: Networking Mode

    CE-IO1600 User Manual 3.1.2 Networking mode Check to make sure that the computer network and the router/switch connected to io are in the same network. Note: generally, there are multi-level networks in the enterprise. When the computer is connected to the wireless network and the io is connected to the router through a network cable, it must be confirmed that the router connected to the io is the same as the wireless WIFI router.
  • Page 12 CE-IO1600 User Manual ➢ Check whether the IP to be modified by the device is occupied / 13...
  • Page 13 CE-IO1600 User Manual ➢ Revise IP / 13...
  • Page 14: Tcp/Udp Configuration

    CE-IO1600 User Manual ➢ Researching 3.1.3 TCP/UDP Configuration Mode Instruction ① The device is used as the server side; ② Support two Clients to use different port numbers to communicate TCP Server with the device. ① The device is used as the Client;...
  • Page 15 CE-IO1600 User Manual 3.1.3.1 TCP Server 3.1.3.2 TCP Client ➢ Mode revisement / 13...
  • Page 16 CE-IO1600 User Manual ➢ Login information packet (handshake packet) When using the TCP Client mode, the device will send a handshake message when connecting to the server for the first time as a client, which can be customized and modified.
  • Page 17 CE-IO1600 User Manual 3.1.3.3 UDP Server 3.1.3.4 UDP Client / 13...
  • Page 18: Communication Test

    CE-IO1600 User Manual Communication Test Working Mode Test software/method TCP Server JYNetConfigEn Network Test Tool TCP Client JYNetConfigEn Network Test Tool UDP Server Network Test Tool UDP Client Network Test Tool 3.2.1 Test Software JYNetConfigEn Download link: https://onefexindustrial.com/ethernet-io-module 3.2.2 Network Test Tool ➢...
  • Page 19 CE-IO1600 User Manual ◼ Create a device-oriented iP and port in TCP Client mode: ◆ Send command test / 13...
  • Page 20 CE-IO1600 User Manual 3.2.2.2 TCP Client Mode Connection Example: ◆ IO Parameter ◆ Create a TCP Server and listen on port 10000: / 13...
  • Page 21 CE-IO1600 User Manual ◼ Send command to test 3.2.2.3 UDP Server Mode Connection Example: ◆ IO parameter: / 13...
  • Page 22 CE-IO1600 User Manual ◼ Create a UDP Client pointing to the IP and port of the device Server: ◆ Send command to test / 13...
  • Page 23 CE-IO1600 User Manual 3.2.2.4 UDP Client Mode In UDP mode, the connection is actively initiated by the server. So the io is required to be configured with automatic return function. Connection Example: ◼ IO parameter: ◆ The current computer establishes a UDP Server and monitors port 10001:...
  • Page 24 CE-IO1600 User Manual ◆ Send command to test After establishing communication, the test is as below: / 13...
  • Page 25: Modbus Tcp Testing

    CE-IO1600 User Manual 3.2.3 Modbus TCP Testing Ethernet I/O supports Modbus RTU and Modbus TCP two communication protocols; Modbus TCP test using Modbus POLL software. 3.2.3.1 Software Download Download Link: https://www.modbustools.com/download.html 3.2.3.2 Test Instruction ➢ Set up communication test ➢...
  • Page 26 CE-IO1600 User Manual Brief description of the function code: Function Code Explaination Relay Output Digital Input Analog Input 03(keep) Analog Input 04(read only) 3.2.3.3 Communication OK Take relay control as example: / 13...
  • Page 27 CE-IO1600 User Manual / 13...
  • Page 28: Device Address

    CE-IO1600 User Manual Device Address 3.3.1 Download ➢ JYDAMEn Download Link: https://onefexindustrial.com/ethernet-io-module 3.3.2 Revise Address PLC Communication ➢ Ethernet IO supports Modbus RTU and Modbus TCP. When PLC communicates with io through TCP to establish Modbus TCP communication, the network channel mode needs to be changed to [Modbus TCP] ➢...
  • Page 29: Development Data Instruction

    CE-IO1600 User Manual Development Data Instruction Flash On Flash Off Mode Manual mode: Each time the relay is operated, the relay will flip once (open when closed, closed when open); Flash on mode: Each time the relay is operated, the relay will be closed for 1 second (actual time [unit second] = set number * 0.1) and then automatically disconnected;...
  • Page 30 CE-IO1600 User Manual Coil Control 4 0x0004 The 4th DO Coil Control 5 0x0005 The 5th DO Coil Control 6 0x0006 The 6th DO Coil Control 7 0x0007 The 7th DO Coil Control 8 0x0008 The 8th DO Write coil...
  • Page 31: Command List

    CE-IO1600 User Manual Command List Scene RTU format (send in hexadecimal) Query 16 DOs ‘status FE 01 00 00 00 10 29 C9 Return query information FE 01 01 00 61 9C Control the 1 DO on FE 05 00 00 FF 00 98 35...
  • Page 32: Command Details

    CE-IO1600 User Manual FE 05 00 0B 00 00 A8 07 Control the 12 DO off Control the 13 DO on FE 05 00 0C FF 00 58 36 Control the 13 DO off FE 05 00 0C 00 00 19 C6...
  • Page 33: Flash On Flash Off Command

    CE-IO1600 User Manual 00 10 Number of queries The number of DOs to be queried CRC16 CRC16 checksum of the first 6 bytes of data 29 C9 DO return information: Return code: FE 01 02 00 00 AD E8 Field...
  • Page 34: All On And All Off Command

    After-sale Service Commitment OneFex provides after-sales service of the device within one year from the date of sale. But for damage caused by improper use, you need to send it back and take the freight for repair or adjust. Make sure that the package is in good condition to avoid damage during transportation.
  • Page 35 This document does not grant any intellectual property license, express or implied, or by hijacking or otherwise. OneFex assumes no responsibility other than those specified in the terms and conditions of sale of the product. And makes no warranties, express or implied, for the sale and/or use of this product, including the product's fitness for a particular purpose, merchantability, or liability for infringement of any patent, copyright or other intellectual property rights.

Table of Contents