ICON BIA-iPROTECT Installation And Operation Manual

ICON BIA-iPROTECT Installation And Operation Manual

Single-phase pump control and protection module

Advertisement

Quick Links

Auto Restart Pump Controller
BIA-iPROTECT
Single-Phase Pump Control and Protection module PN 802697
Installation and Operation Manual
1
iCON iPROTECT Instruction Manual Rev 4.4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BIA-iPROTECT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ICON BIA-iPROTECT

  • Page 1 Auto Restart Pump Controller BIA-iPROTECT Single-Phase Pump Control and Protection module PN 802697 Installation and Operation Manual iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 2: Table Of Contents

    1. Introduction Thank you for choosing a Bianco iCon iPROTECT Intelligent Pump Controller. An iPROTECT provides significant protection for direct start (DOL), single phase pumps from 0.37kW – 2.2kW with PSC MOTORS (Permanent-Split Capacitor) with start and run windings). It also offers a number of control and operation modes to suit a variety of applications.
  • Page 3: Technical Specifications

    Children should be supervised to ensure that they do not play with the appliance. iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 4: Display

    Control by floats Control by floats switch or probes or probes Control by pressure Control by level Control by level transducer transducer transducer Function switch located upper right-hand side of main board. Cycle power after changing. iCON iProtect Instruction Manual Rev 4.4...
  • Page 5: Operation And Programming - Navigation

    6. Operation and Programming - navigation In situations where it isn’t possible to run the pump to achieve a real-world calibration, enter the P1 kW rating manually at Parameter 008 See Pg 17 for additional notes regarding calibration iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 6: Program Parameters

    Overload trip response time in minutes (M) Range 0 - 60 minutes Default value is 5 minutes Under / Over voltage trip response time in minutes (M) Range 0 – 60 minutes Default value is 2 minutes iCON iProtect Instruction Manual Rev 4.4...
  • Page 7 If this function is activated, to unlock the controller hold MODE button then press and hold the STORE/SET button. The controller will count down 6 – 10 seconds. Release all buttons and the controller will switch to manual mode with all buttons unlocked iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 8: Programming For Cutter/Grinder/Macerating Pumps

    Note: if the running power is less than 75% of the rated full load power check the pump sizing or system. For pumps controlled by their own float, see Section 9. Program parameter 009 to 0% iCON iProtect Instruction Manual Rev 4.4...
  • Page 9: Drainage Mode - Electrical Connections; Floats Or Probes

    Terminals 1 and 2 are for connection to motor thermal protection. If not available leave the jumper wire in. Terminals A+ and B- are for MODBUS communication (RS485). Probes are not recommended for use with black water or contaminated liquids. iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 10: Drainage Mode - Control Via Pump Float

    The pump will run if the controller is in Auto mode The pump starts and runs. Related to terminals 10 and 12 Ensure the controller is set to AUTO MODE when finished iCON iProtect Instruction Manual Rev 4.4...
  • Page 11: Transfer Mode - Electrical Connections; Floats Or Probes

    Bridging terminals 4,5 and 6 allows for control by the destination inputs only. The display screen will show the water source as full. Probes are not recommended for use with black water or contaminated liquids. iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 12: Transfer Mode - Lcd Running State Images

    If there is sufficient liquid at the source the pump will start Destination liquid is above the high-level setting. The controller will turn the pump off Ensure the controller is set to AUTO MODE when finished iCON iProtect Instruction Manual Rev 4.4...
  • Page 13: Boosting Mode - Electrical Connections; Floats Or Probes

    The under-load function of the iPROTECT also acts as a reliable automatic stop function against pump dry- running. Jumpers can be fitted between terminals 4,5 and 6 if preferred iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 14: Boosting Mode - Lcd Running State Images

    A relay may be necessary. Never connect 240V supply to control terminals 1 – 12 or to N1, N2 or C Ensure the controller is set to AUTO MODE when finished iCON iProtect Instruction Manual Rev 4.4...
  • Page 15: Bore Pumps - Connecting 2 Wire And 3 Wire Bore Pumps

    16. Bore Pumps - Connecting 2 wire and 3 wire bore pumps iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 16: Communication Link - Rs485

    1200 metres max by shield twisted pair cable (STP) for RS485 & CAN 5000 metres max by STP and RS485 extender STP-120U one pair 20AWG for RS485 & CAN RS485 extender 5000 metres (9600bps) iCON iProtect Instruction Manual Rev 4.4...
  • Page 17 • Turn the iProtect off • Turn the iProtect on • Auto Calibrate and save • Run the pump manually • Cycle the power (on/off) and check the values are as required. • Alter parameters manually as necessary. iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 18: Fault Messages - Possible Causes And Solutions

    Reinstall jumper on protection terminals has been temperature protection removed. terminals. Pump motor temperature high Wait until pump motor and pump thermal switch in open temperature reduces. state (if connected). Investigate cause for Overheating. iCON iProtect Instruction Manual Rev 4.4...
  • Page 19: Warranties - Terms And Conditions

    New Zealand. 8) Our warranty commences from the date of purchase of the above-mentioned pumps. Proof of purchase is required before consideration under warranty is given. Record your date of purchase in the space below and retain this copy for your records. Date of Purchase ..........Model Purchased ..........iCON iPROTECT Instruction Manual Rev 4.4...
  • Page 20 For any queries regarding use of the contained information please feel free to contact White International Pty Ltd. iCON iProtect Instruction Manual Rev 4.4...

This manual is also suitable for:

802697

Table of Contents