CLEANING AND SANITIZING PROCEDURE

TOOLS REQUIRED

1
Medium Phillips screwdriver
1
Flat screw driver
1
Pair of safety gloves
1
Bucket / container
1
Brushes
1
Clean clothe
1
Approved cleaner / sanitizer
FREQUENCE
Cleaning :
Every six months
Sanitizing :
Every month
NOTE. THE FOLLOWING PROCEDURE CAN BE
USED FOR EITHER SANITIZING OR DE-SCALING
THE ICE MACHINE.
NEVER MIX THE SANITIZING SOLUTION WITH THE
DE -SCALING SOLUTION.
IN CASE THE MACHINE NEEDS TO BE SANITISED
AND
DE-SCALED,
THOROUGHLY, THEN FIRST DE-SCALE, AND AFTER
PROPER
WASHING
SANITATION.
WARNING. When using any chemical, protection of
hands and eyes should be worn.
上海市虹梅南路4999 号 8 号楼 P.C. 201109 Tel:(86 21)51691855 Fax:(86 21)51687575
ICE DISPENSER
CLEAN
THE
MACHINE
AND
RINSING,
DO
上海安继行餐饮设备有限公司
TC 180
NOTE. De-scaling is recommended every 6 months in
average water hardness conditions, while sanitizing
should take place once a month. Under extreme water
hardness conditions we recommend to de-scale every
two – three months, and to sanitize every two weeks.
Sanitizing regularly will reduce bacteria growth, which is
natural in all water circulation systems as ice machines.
NOTE. Always follow approved Sanitizer / De-scaler
manufacturers instructions when preparing the Sanitizer
/De Scaler solutions.
CAUTION. Ice Machine Sanitizers / De-scalers
contain
concentrated de-scaler / sanitizer comes in contact
with skin, flush with water. If swallowed, do NOT
induce vomiting. Give large amounts of water or
milk. Call Physician immediately. KEEP OUT OF THE
REACH OF CHILDREN.
THE
acids.
Acids
may
cause
burns.
If

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC 180 and is the answer not in the manual?

Questions and answers

Summary of Contents for Angelhood TC 180

  • Page 1 上海安继行餐饮设备有限公司 Page 1 上海市虹梅南路4999 号 8 号楼 P.C. 201109 Tel:(86 21)51691855 Fax:(86 21)51687575 ICE DISPENSER TC 180 CLEANING AND SANITIZING PROCEDURE TOOLS REQUIRED NOTE. De-scaling is recommended every 6 months in average water hardness conditions, while sanitizing should take place once a month. Under extreme water...
  • Page 2 4. Remove water drip tray grid PROCEDURE 1. Disconnect power from the unit 2. Close water tap on water supply line 5. Remove funnel/conveyer turning the same ¼ counter - clockwise NOTE. Be sure that no other equipment in use can suffer of the turn OFF of water 6.
  • Page 3 ….. remove the same 8. Whether the bottom panel is not previously taking off, remove screws and panel as 9. Remove drain fitting plastic nut 7. Kindly remove front panel’s plastic screws cover caps, 10. Kindly pull out front panel from the unit frame …….
  • Page 4 11. Disconnect monitoring panel wire plug the ……. 14. Kindly lift-up the lower part of the ice chute meanwhile take-off plastic bin cover with agitator drive motor …… ….. dispensing sensor photocell plug either ……doing so You get free access at inside part of ice 12.
  • Page 5 16. …… then the stainless steel bottom 17. Using protective gloves and glasses, mix cleaning sanitizing/cleaning solution in a bucket. 19. Henceforward rinse those by fresh water then NOTE always follow approved Sanitizer/De-scaler manufacturers instructions and dilution when preparing Sanitizer/De-scaler solutions).
  • Page 6 22. …. the bottom area of the ice bin’s cover and…… 23. …ice level photocells surfaces 20. Clean inside area / surface of the ice bin then…… 24. Reinstall stainless steel bottom removed at # 16 paying attention that its opening windows faces toward to the ice funnel area at # 5.
  • Page 7 28. Clean drip-tray and …… ……reinstall grid of the same...

Table of Contents