Seam test station INSTRUCTION MANUAL 296-12-19 210/002 Betriebsanleitung engl. 03.12...
Page 2
The reprinting, copying or translation of PFAFF Instruction Manuals, whether in whole or in part, is only permitted with our previous authorization and with written reference to the source. PFAFF Industriesysteme und Maschinen AG Hans-Geiger-Str. 12 - IG Nord D-67661 Kaiserslautern...
Proper use Proper use The seam connections, which are sealed with a seam sealing tape, are checked at the seam test station for water-tightness in accordance with DIN 20811. The test is conducted for outdoor wear, ski, surfi ng and diving suits, and for shoes.
Specifi cations Specifi cations Max. clearance underneath test plates: ............. approx. 38 mm Fill water: ......................distilled water Dimensions: Length: ......................approx. 450 mm Width: ......................approx. 300 mm Height ......................approx. 620 mm Connection data: Pressure min.: ........................1 bar Pressure max.: ........................
Disposal of Machine Disposal of Machine ● Proper disposal of the device is the responsibility of the customer. ● The materials used for the machine are steel, aluminium, brass and various plastic materials. The electrical equipment comprises plastic materials and copper. ●...
Arbeitssymbole Explanation of symbols In this instruction manual, work to be carried out or important information is accentuated by symbols. These symbols have the following meanings: Note, information Cleaning, care Lubrication Maintenance, repairs, adjustment, service work (only to be carried out by technical staff)
Preparation Preparation Setting the test material thickness ● Screw on union nut 1. ● Insert the plastic plate or the lattice supplied depending on the material, and screw in place with the union nut 1. ● Loosen counter nut 2 and set the material thickness to be processes by turning the clamping plate 3.
Prüfen Testing Testing (Version without pneumatics connection) Fig. 7 - 01 ● Place the material for testing underneath the clamping lever 1 and press down on the lever 2. ● Close bleeding screw 3. ● Generate the desired test pressure via the pump bellow 4. Open the bleeding screw 3 after the test process to depressurise the system.
Prüfen Testing (Version with pneumatics connection) open closed Fig. 7 - 02 ● Place the material for testing underneath the clamping plate 1 and press down on the lever 2. ● Close the air stop cock 3. ● Connect compressed air at pressure reducer 4. ●...
Maintenance Maintenance Maintenance intervals Lubrication .......................annually Manometer replacement ..................annually Lubrication Fig. 8 - 01 ● Lubricate guide 1 with a little grease once a year. Only use Gleitmo 585 M heavy duty grease, part no. 280-1-120 269. Manometer replacement ● The installed manometer has been tested and should be replaced once a year. ●...