Radio Doorbell transmitter. (If the radio doorbell is available in the local frequency). In addition to radio devices, the R16 has 1 hardwired zone and 1 hardwired tamper input for connection of a wired detection device and external siren cover tamper switch.
R16 supports all radio devices as shown below. All late model transmitters send encrypted transmissions to prevent eavesdropping and substitution. fixed transmitters can send a regular supervision signal which the R16 monitors to ensure system security. * Available in selected areas.
8. Turn on the plug pack. Front housing Note 1: When power is applied, the R16 will enter Disarmed mode, unless it was in Armed or Monitor mode when previously running, in which case it will resume in the previous mode - UNLESS the box tamper or external tamper inputs are unsealed.
Page 6
CABLE ENTRY Cable for the plug pack and optional accessories can be drawn through a cavity wall into the rear of the R16 or on the surface via conduit into the top of the R16 rear housing as shown below.
Timed output for connection of maximum 1 x 12V screamer. ONBOARD SIREN (BUILT-IN) The onboard piezo siren is an integral part of the R16 electronics. It is used for keypad beeps, doorbell chime, arm/disarm chirps and internal siren on alarm. The internal Siren can be disabled by program option P60E 8E.
R16 KEYPAD AUDIBLE & VISUAL FEEDBACK The R16 onboard keypad provides the facility for user level and installer level programming and all user operation and emergency functions. The keys are soft-touch silicon rubber and are backlit for high visibility. Any keypress will turn on the backlighting for 4 minutes.
This test automatically turns off after 2 minutes. Display Test. Press and hold keypad button ‘E’ for 1.5 seconds. Turns on all LCD icons while the button is pressed. R16 - Installation and Programming Manual...
OPERATION OPERATING MODES The R16 will operate in one of the following modes: ARMED. The system is “On” and ready to detect intrusion. DISARMED. The system is “Off”. This is the normal mode when the premises are occupied. Day Zones and 24 Hour Zones (if configured) are active.
Shortcut method (Arming shortcut must be on, P62E 5E). Memory can be viewed in the disarmed state. then press repeatedly to display the last 20 events in memory. then press to exit Memory mode. R16 - Installation and Programming Manual...
DIALLER LINE Indicates minimum telephone line DC voltage was not detected for a 2 minute period. If Telephone Line Monitor is enabled, flash the LCD LINE icon and beep FAULT keypad. R16 - Installation and Programming Manual...
Indicates the dialler was not able to successfully contact the central monitoring station. Flash the LCD LINE icon. All alarm types can be reported to the Central station. See page 48 for a full list of Contact ID reporting codes. R16 - Installation and Programming Manual...
QUICK START PANEL PROGRAMMING The R16 is supplied pre-programmed with factory default values that should suit most installations. The steps below will show you how to program the Master Code (User Code 1), and the Client Code and telephone number for central station monitoring.
QUICK START RADIO PROGRAMMING As a radio system, the R16 can be installed with a minimum of wiring. If an external siren or strobe light is not being used, the only essential wiring is connection of the plug pack. The steps below will show you how to program one Radio PIR and one Radio Key.
Page 17
This page is intentionally blank R16 - Installation and Programming Manual...
FROM POWER UP 1. Power-up with the internal box tamper or external tamper open. Note: The panel will The R16 will then be in Installer Program Mode. remain in Installer P r o g r a m M o d e USING THE KEYPAD indefinitely.
SPECIAL P0E to P9E. CHARACTER KEYPAD ENTRY KEYPAD DISPLAYS The leading zero is not PAUSE (1.6sec) ARM Key necessary. * (Star) MONITOR Key # (Hash) EXCLUDE Key R16 - Installation and Programming Manual...
Page 20
Press: P05E 2E Doorbell Tune, P06E. P06E DOORBELL TUNE* The R16 has nine built-in doorbell tunes to choose from. The doorbell PROGRAM MODE LEVEL: is activated by the optional Radio Doorbell transmitter. (Most User, Installer, Remote by PC. transmitters can be programmed to operate the Doorbell function, FACTORY DEFAULT: see page 25, Extra Option for Radio Keys).
Page 21
Use P08E 0E to test Radio Keys, (press Panic button). Note that in this • The signal strength beeps mode, the R16 will respond to radio signals from any programmed will sound only the first time radio device. To avoid confusion from multiple radio signals, this test the radio device is activated.
Page 22
PROGRAMMING P09E PROGRAM RADIO DEVICES The R16 has sixteen radio zones which can accept radio devices PROGRAM MODE LEVEL: such as radio PIRs, radio reed switches, radio smoke detectors. Installer, Remote by PC. Each of the sixteen radio zones will accept one radio device.
Page 23
PROGRAMMING P10E PROGRAM RADIO KEYS The R16 will accept up to 14 Radio Keys to be used for remote PROGRAM MODE LEVEL: control wireless Arming/Disarming and Panic functions. User, Installer, Remote by PC. Radio Keys are programmed to one of the 15 User Code slots with FACTORY DEFAULT: the easy to use radio ‘Learn’...
Page 24
3E, Medical: The Panic Button will trigger the Medical alarm. defaulted with Extra Option 1E 4E, Ignore Panic: Disables Panic Button on radio keys. enabled, (Panic alarm). 5E, Doorbell: The Panic Button will sound the R16 doorbell feature. The Extra Option for a user code slot can be programmed...
Page 25
• Open/Close reports are identified by user number when the control panel is central station monitored. Shortcut arming, (ARM + E, (if enabled), is sent as User 25. RELATED OPTIONS: P10E, Program Radio Keys R16 - Installation and Programming Manual...
Page 26
EXIT DELAY TIME The Exit Delay Time is the time given to secure and exit the premises PROGRAM MODE LEVEL: after the R16 is Armed. All zones (except 24hr zones) are inactive User, Installer, Remote by PC. during the Exit Delay time.
Page 27
2. Press: [1-16] E to enable each zone for this option. or Instant. • To deselect a zone from this option, program it to be Delayed or Instant. • Zone light/s on indicates which option/s are enabled. R16 - Installation and Programming Manual...
Page 28
2. Press: [1-16] E to enable each zone for this option. • To deselect a zone from this option, program it to be Delayed, Instant or Handover. • Zone light/s on indicates which option/s are enabled. R16 - Installation and Programming Manual...
Page 29
• To deselect a zone from this option, program it to be Delayed, • Doorway alert for a shop. Instant or Handover. • Zone light/s on indicates which option/s are enabled. RELATED OPTIONS: P64E 2E, Brief Day alarm. Programs the behaviour of Day Zone alarms. R16 - Installation and Programming Manual...
Page 30
This option also disables the PIEZ internal screamer output. (Default =OFF). PROGRAMMING SEQUENCE 1. Press: P60E 2. Press: [1-8] E to toggle each option on or off. Zone light/s on indicates which option/s are enabled. R16 - Installation and Programming Manual...
Page 31
7=ON, Enabled. the external siren. RELATED OPTIONS: PROGRAMMING SEQUENCE P60E 6E, Auto Exclude Zones. 1. Press: P62E 2. Press: 7E to toggle the option on or off. Zone light on indicates the option is enabled. R16 - Installation and Programming Manual...
Page 32
2 seconds, (right hand STAR key). The keypad beeper will sound 8 warning beeps. The dialler reports a Medical alarm, (if enabled by P75E 2E). OFF = No Medical Alarm. ON = Keypad Medical Alarm is enabled. (Default = OFF). R16 - Installation and Programming Manual...
Page 33
The R16 will raise a radio jamming alarm if 30 seconds of continous in-band radio signal is detected. FACTORY DEFAULT: Note - The R16 needs to be powered up for a minimum of 10 minutes 1E = OFF to obtain a "no radio signal" reference level before it is able to detect 2E = OFF a radio jamming signal.
Page 34
P67E RADIO SUPERVISION TIME PROGRAM MODE LEVEL: The SUPERVISION TIME is the time allowed between radio transmissions received by the R16 from any Supervised Radio Installer, Remote by PC. Detector. FACTORY DEFAULT: The SUPERVISION TIME setting is from 1 to 168 hours.
Page 35
Special characters such as Pauses, star or hash characters can be included in a telephone number dialling sequence by using the keys in the table below. SPECIAL CHARACTER KEYPAD KEY KEYPAD DISPLAY PAUSE (1.6sec) * (Star) MONITOR # (Hash) EXCLUDE R16 - Installation and Programming Manual...
1. Press: P76E Restorals. 2. Press: [1-16] E to toggle each zone on or off. Zone light/s on indicates which option/s are enabled. RELATED OPTIONS: P74E, Report Zone Alarms. P82E 1E – 4E, Sending Restorals. R16 - Installation and Programming Manual...
Page 37
ON = Exit From Installer Mode reporting is enabled. (Default = OFF). PROGRAMMING SEQUENCE 1. Press: P75E 2. Press: [1-8] E to toggle each option on or off. Zone light/s on indicates which option/s are enabled. R16 - Installation and Programming Manual...
Page 38
P74E, Report Zone Alarms. P82E 4E: Send Restoral on Disarm always. PROGRAMMING SEQUENCE 1. Press: P82E 2. Press: [1-4] E to toggle each option on or off. Zone light/s on indicates which option is enabled. R16 - Installation and Programming Manual...
Page 39
E.g., If you are programming the panel at 5pm and you want test calls DAYS HOURS to be sent at 1am. Enter P84E 8E. (5pm + 8hrs =1am). P83E and P84E timers start on exit from Installer program Mode. R16 - Installation and Programming Manual...
Page 40
ON = Check for dial tone, hang up on busy tone. NOTES: PROGRAMMING SEQUENCE 1. Press: P87E 2. Press: 2E to turn the option on or off. Zone light/s on indicates the option is enabled. R16 - Installation and Programming Manual...
Page 41
ON = Report Supervision Alarms enabled. Alarms disabled. PROGRAMMING SEQUENCE RELATED OPTIONS: P67E, Radio Supervision Time. 1. Press: P88E 2. Press: 6E to turn the option on or off. Zone light/s on indicates the option is enabled. R16 - Installation and Programming Manual...
Page 42
OFF = Remote Disarming is disabled. ON = Remote Disarming is enabled. (Default = OFF). PROGRAMMING SEQUENCE 1. Press: P90E 2. Press: [1-4] E to toggle each zone on or off. Zone light/s on indicates which option/s are enabled. R16 - Installation and Programming Manual...
Page 43
Programmable from 1 to 16 rings. Enter a value between 1 and 16. 1= 1 double-ring. PROGRAMMING SEQUENCE NOTES: 1. Press: P91E The digits of the existing value will be displayed. 2. Press: [required rings] E The digits of the new value will be displayed. R16 - Installation and Programming Manual...
FACTORY DEFAULT USER CODES PROGRAM MODE LEVEL: This option erases all Keypad Codes and Radio Key codes. Installer, Remote by PC. PROGRAMMING SEQUENCE FACTORY DEFAULT: [not applicable] 1. Press: P97E 2. Press: 3E Factory defaults are restored.. R16 - Installation and Programming Manual...
Page 45
• The Installer code can be successfully programmed. changed but it cannot be deleted. Any attempt to delete the installer code will make it revert back to the factory default of 000000. R16 - Installation and Programming Manual...
Page 46
Press the # key for 2 seconds during pauses in the number is programmed audible message. (On mobile phones, press the # key in short bursts. Many at P70E or P71E. mobile phones enter sub menus if the # key is pressed continuously). R16 - Installation and Programming Manual...
120 Panic alarm Open/Disarm 121 Duress alarm 130 Burglary alarm Close/Arm 133 24 hour alarm Shorcut Arm (ARM + E) 355 Radio jamming alarm Cancel/Disarm Zone Manual Exclude Zone Auto Exclude Exit Install mode Test Report R16 - Installation and Programming Manual...
Page 48
5. Now enter a valid User Code followed by the button. COMMANDS. The R16 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again. [User Code] 6.
Long life lithium battery powered, simply screw it to the wall. RR2 UNIVERSAL TRANSMITTER The doorbell chime is heard through the R16 panel onboard siren. Choose from one of 9 doorbell WIRELESS VIBRATION ANALYSER tunes built-in to the R16 panel.
Page 50
Pet Aware features. The R15PET detects humans but is immune to pets of up to 25kg in weight, (or multiple pets up to a total of 15kg). R15PET may not be available in all regions R16 - Installation and Programming Manual...
Monitor Zones No zones P52E 24hr Zones No zones P53E Day Zones No zones P60E Entry beeps [not used] [not used] Tamper Siren Lockout [not used] Auto Exclude Zones Keypad Backlight Blanking Disable onboard siren R16 - Installation and Programming Manual...
Page 52
Central Station Telephone. No. 1 none P71E Central Station Telephone. No. 2 none P72E Client Account No. 0000 Options marked "u" can be programmed in User Program Mode All options can be programmed in Installer Program Mode R16 - Installation and Programming Manual...
Page 53
0 hrs P85E Auto, Pulse or DTMF depending on dial tone Pulse Dialling always DTMF Dialling always P86E Disable Dialler P87E Check For Dial Tone P88E Open/Close Reports Alarm Cancel Report Report Supervision Alarms R16 - Installation and Programming Manual...
Page 54
Remote Disarming P91E Required Rings to answer incoming calls P96E Clear Event Memory P97E Factory Default Panel Options Factory Default Radio Zones Factory Default User Codes & Radio Keys P99E Program Installer Code 000000 R16 - Installation and Programming Manual...
Page 55
R16 CONTROL PANEL INSTALLER MANUAL Revision 1 Document Part Number 890–XXX COPYRIGHT NOTICE All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without...