TYPICAL OPERATION For proper filtration, operate the pressure pond filter 24 hours a day, year round. Start the ViaAqua® pond pump. Verify that all seals and connections are not leaking. BACKWASH OPERATION Remove the cap from the backwash/drain port. Connect a barbed fitting with a piece of tubing and secure with a hose clamp.
Page 8
3. Flip out safety lock and remove lid retainer clamp. 4. Remove the lid of the filter. Handle with care. The UV bulb and quartz sleeve is made of glass. 5. Remove the intake and output flares. 6. Remove and rinse foam pads. Replace them if necessary. 7.