WASTEFLOW ™ Lines (or emitter lines) These lines carry the water into the area to be irrigated. WASTEFLOW™ lines are connected to the submain and flush lines usually with grommet - barbed fittings. (In small systems < 1500 l/hr capacity through the system, the actual Wasteflow tube can be used for submain &...
Rigid PVC is usually employed for the larger installations. Poly tubing is easier to work with because it is flexible. In small systems with less than 1500 l/hr flow capacity the actual Wasteflow tube can be used as the submain. This can simplify connections and installation.
BOD and TSS values of less than 20 mg/l is produced in the pre treatment system. Table 1. Minimum surface area required to dispose of 1000 litres per day Soil absorption rates Design Total Wasteflow Wasteflow Soil Est.Soil Hydraulic...
100 kPa. These flows can be obtained from Table 2 below. c) In the case that the terain is sloping use pressure compensating PC Wasteflow, in which case output of each driper will remain constant for pressures from 50 - 400 kPa.
Then install the main lines. These should be buried at a depth of 30 to 45 cm, well below the depth of the WASTEFLOW ™ lines (10 to 30 cm). If there is a risk of freezing bury mainlines below the frost line. At all times avoid getting debris into the system.
Table 4. Subsurface drip installation methods. INSERTION ADVANTAGES DISADVANTAGES METHOD a) Hand Trenching* •Handles severe slopes and confined areas •Slow •Uniform depth •Labor intensive Disrupts existing turf and ground •Back fill required. b) Oscillating or Vibrating • Fast in small to medium installations. •Depth has to be monitored closely.
Appendix 1: Hydraulic Details "Classic" Drip Line - Pressure vs Emitter flow rates . Pressure kPa Flow LPH 16 mm 2.4 l/hr Wasteflow PC Pressure Loss Tables Internal Diameter (mm) = 14 mm Maximum Recommended Run Length (m), vs Pressure (kPa) Inlet Pressure (kPa) 0.6 m Dripper Spacing...
WARRANTY Product Warranty Geoflow products as supplied by Triangle Filtration, are warranted to be free from defects in material and workmanship for a period of 10 years when installed below ground, and a period of 2 years when installed above ground from the date of initial installation.