Description

The 1100R Wireless Repeater provides increased communication range by forwarding messages from the transmitter to the
wireless receiver. Up to eight repeaters can be installed on a wireless system. The repeater is powered from a
12 VDC power supply and includes a 24-hour battery backup.
provides built-in survey capability to allow for single-person installations, eliminating the requirement for an external
survey kit.
1100X, 1100XI, or 1100XH Receiver using Version 106 software.
1100D, 1100DI, or 1100DH Receiver using Version 106 software.
XT50 Series panel with built-in wireless using
Version 101 (11/21/08) software.

What is Included

The 1100R Wireless Repeater includes the
following items:
• One Model 1100R Repeater
• One Lithium Polymer Rechargeable Battery
• One Model 378 Barrel Connector with cord
for connecting a 12 VDC Power Supply
• Zone name and number label
• Serial number label
• Hardware pack
Optional items available:
• One Model 376 Plug-in DC Power Supply
Serial Number
For your convenience, an additional pre-printed
serial number label is included. Prior to installing
the repeater, record the serial number or place
the pre-printed serial number label on the panel
programming sheet. This number is required
during programming. As needed, use the zone
name and number label to identify the repeater.

Panel Programming the Repeater

To program the repeater in the panel a wireless
zone is used. Program the wireless House Code in
System Options prior to adding DMP wireless zones to the system. Follow these steps in Zone Information:
• Zone Type: Select an Auxiliary zone type and program trouble for both the open and short conditions.
• Wireless: Select YES to program the zone as a DMP wireless zone.
• Serial Number Entry: At the Serial Number: prompt, enter the repeater's eight-digit serial number.
Note: If using multiple repeaters, they must be programmed as sequential zone numbers.
• Supervision Time: Press COMMAND to accept the default time of 240 minutes. Press any top row key to select the
supervision time required for the wireless repeater. Press the Select key under the required number of minutes. A
check-in time of 60 or 240 minutes should be selected.
The repeater must check in at least once during this time or a missing condition is indicated for that zone.
Since 1100R repeaters automatically check in based on the supervision time selected for the wireless zone, no
additional programming is needed. Any programming prompts for contact or other information can be ignored.
Note: When an 1100 series receiver is installed, powered up, or the panel is reset, the supervision time for any
repeaters and transmitters are reset.
Refer to the XR500 Series Programming Guide (LT-0679), XR100 Series Programming Guide (LT-0896), XT30/XT50
Programming Guide (LT-0981), or the XRSuper6/XR20/XR40 Programming Guide (LT-0305) as needed.
Inst alla tIon GuIde
1100R Wireless Repeater
Using the on-board LEDs, the 1100R Wireless Repeater
Battery
Start
DC Power
Supply
Barrel Jack
Squeeze
to Remove
Cover
LEDs
Mounting Hole
Locations
J1
1
Figure 1: 1100R Repeater PCB Layout
Tamper
J4
1
Switch
Squeeze
to Remove
Cover

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1100R and is the answer not in the manual?

Questions and answers

Summary of Contents for Digital Monitoring Products 1100R

  • Page 1 The repeater must check in at least once during this time or a missing condition is indicated for that zone. Since 1100R repeaters automatically check in based on the supervision time selected for the wireless zone, no additional programming is needed. Any programming prompts for contact or other information can be ignored.
  • Page 2 The 1100R provides the option to power up using the Lithium battery only for survey operation. Briefly short the Battery Start pads together to power up. Refer to Figure 1. Survey LEDs The 1100R automatically begins establishing communication with the 1100 series receiver at power up. The 1100R Green Survey LED turns on steady when successful communication with the receiver is established. The 1100R Red Survey LED turns on steady when communication cannot be established with the receiver. Relocate the repeater until the Green LED turns on steady indicating successful communication has been established. This Green/Red...
  • Page 3 Optional External DC Plug-in Power Supply When using the optional Model 376 plug-in DC power supply, mount the Barrel Jack 1100R near a wall outlet. In addition to powering the repeater, the DC plug-in power supply also charges the back-up battery. Barrel Rechargeable Battery Connector Plug-in Power The 1100R rechargeable battery is used to provide up to 24 hours of Supply backup battery power when AC power is not available.
  • Page 4 FCC Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.