  • Page 1 EFCip Operation and Maintenance Manual Electric Torque Multiplier Series E...
  • Page 2: Table Of Contents

    Operation and Maintenance Manual Content Table Foreword Page Congratulations on your purchase of an alkitronic® electric Reception Control and Packaging torque multiplier. This high quality product sets unique General Description international standards and satisfies high safety levels. In Model Description order to preserve these features, your assistance by regular maintenance is required.
  • Page 3: A Reception Control And Packaging

    EFCip - torques up to 6,500 Nm* alkitronic® ECWip angle tools for restricted access - high op- erating comfort. Torque values are the same as model EFCip with additional equipment: OLED-Display, menu guidance and bolting programmes as for example combined torque/ angle procedure.
  • Page 4: Safety Instructions

    Intended use alkitronic® torque multipliers are designed to tighten or loos- en heavy duty bolt connections continuously. Do not use the torque multiplier for any other purpose than its intended use. For other applications please consult alki TECHNIK GmbH.
  • Page 5: Technical Data

    TECHNIK GmbH certified and authorised personnel). All safety and mechanical • Place the alkitronic® torque multiplier on a flat surface. defects must be resolved before resuming opera- • If the DMA is secured with a safety screw, screw out safety tion.
  • Page 6: Preparing For Bolting

    Operation and Maintenance Manual 4. Electric Operation 4.2 Operation panel with OLED-Display 4.1 Primary operation Torque Unit Program e.g. Mode 1 „run“ is displayed only Rocker button when the motor is running CCW direction: Tap operation or quick run Power switch On/Off CW direction: (Luminous button) Tap operation or...
  • Page 7: Bolting Programs

    electric torque multipliers 4.4 Bolting programs 4.4.1 Bolting according to the torque method Adjustment mode 1 - with/without automatic release function After a short time, the display Start Display jumps to the next image. Enter bolting program Confirm input Step 1 Enter final torque Confirm input...
  • Page 8: Bolting With Torque/Angle Procedure

    Operation and Maintenance Manual 4.4.2 Bolting according to the combined torque/angle procedure (option) Adjustment mode 2 - with/without automatic release function After a short time, the display Start Display jumps to the next image. Enter Confirm input bolting program Step 1 Enter Confirm input pre torque...
  • Page 9: Error Messages

    Errors can be reset by using the “M” button, pro- General error Message vided the cause is eliminated. If this fails, your alkitronic® partner will be pleased to help you. Error message as Please take a note of the error code and report it hexadecimal figure to our customer service.
  • Page 10: Mechanic Operation

    Keep your hair, clothing, and gloves away from Correct torque reac- moving parts. Loose clothes, jewellery or long hair tion point in marked can be caught in moving parts (alkitronic® DMA/ area only STACO/STABI/STA). Maintain a safety distance when tightening bolts or nuts.
  • Page 11: Models With Radial/Tangential Drive

    • A sure, stable counter-mount (Fig. 1/1)/(Fig. 2/2) must be ensured. • Always note during the bolting process: - keep the alkitronic® EFCip-R multiplier in a 90 degrees angle to the bolt (Fig. 1). alkitronic® STA - keep the alkitronic® EFCip-SG multiplier in parallel line to the bolt (Fig.
  • Page 12: Ending Or Interrupting The Work

    In the event of repairs the alkitronic® torque multiplier (in original pack- age) must be sent to the appropriate alkitronic® Partner or directly to alki Technik GmbH. The following operation and service requests should be...
  • Page 13: Taking Out Of Operation

    In the event of repairs the alkitronic® torque mul- 2006/42/EG, 2014/35/EU, 2011/65/EU, 2014/53/EU, tiplier must be sent to the appropriate alkitronic® 2014/30/EU and Norms...
  • Page 14: Replacing The Power Cord Plug

    Make sure the power cord is not connected to any power source before cutting off the power plug. CAUTION! Power plug All alkitronic Electric Torque Multipliers are delivered with a three-wired ® power cord with ground conductor. The housing or metal parts are earthed by the...
  • Page 15: Technical Data

    Technical Data EFCip100 Dimensions [mm] *) When loosening a bolted connection, up to 20% higher torque may be required (loosening torque). We will gladly advise you in detail. Models EFCip Type EFCip 10 EFCip 20 EFCip 30 EFCip 40...
  • Page 16 Spare part and repair service alki TECHNIK GmbH Development, Production and Distribution of Bolting Systems Unterlettenweg 4 – 85051 Ingolstadt/Germany – fon +49 841 97499-0 – fax +49 841 97499-90 info@alkitronic.com – www.alkitronic.com EXTRACT FROM OUR PRODUCT RANGE Electric Torque Multiplier Pneumatic Torque Multiplier...